US$229.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 2007-2015: Verification Scheme of Time and Frequency Measuring Instruments Status: Valid JJG 2007: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 2007-2015 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Verification Scheme of Time and Frequency Measuring Instruments
| Valid |
JJG 2007-2015
|
JJG 2007-2007 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Verification Scheme of Time and Frequency Measuring Instruments
| Obsolete |
JJG 2007-2007
|
JJG 2007-1987 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Verification System of Time and Frequency Measuring Instruments
| Obsolete |
JJG 2007-1987
|
PDF similar to JJG 2007-2015
Basic data Standard ID | JJG 2007-2015 (JJG2007-2015) | Description (Translated English) | Verification Scheme of Time and Frequency Measuring Instruments | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A57 | Classification of International Standard | 17.080 | Word Count Estimation | 10,129 | Date of Issue | 2015-12-07 | Date of Implementation | 2016-06-07 | Older Standard (superseded by this standard) | JJG 2007-2007 | Quoted Standard | JJF 1001; JJF 2059.1-2012; JJF 1180 | Regulation (derived from) | ?AQSIQ 2015 Nian (No.148) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the transfer of time-frequency values, including time-frequency measurements from time-frequency measurement standards through the measurement standards to the work of the transfer of equipment, the value of transmission methods and measurement of transmission capacity. In carrying out calibration, can also be used as the basis for traceability. |
JJG 2007-2015: Verification Scheme of Time and Frequency Measuring Instruments---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Scheme of Time and Frequency Measuring Instruments
National People's Republic of China Metrological Verification System
Time and frequency measuring instruments
2015-12-07 released
2016-06-07 implementation
State Administration of Quality Supervision, Inspection and Quarantine issued
Time and frequency measuring instruments
Verification system table
Replacing JJG 2007-2007
Unit. National Time Frequency Measurement Technical Committee
The main drafting unit. China Institute of Metrology
Participated in the drafting unit. Shanghai Institute of Metrology and Testing Technology
Aerospace Science and Industry Group Second Institute 203
The commissioning system table commissioned by the National Time Frequency Measurement Technical Committee is responsible for the interpretation
The main system of the test system.
Zhang aimin (China Institute of Metrology)
Liang Kun (China Institute of Metrology)
Participate in the drafters.
Dong Ling (Shanghai Institute of Metrology and Testing Technology)
Ge Jun (203 Institute of Aerospace Science and Industry)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 measurement basis (1)
3.1 Name and magnitude (1)
3.2 Frequency Uncertainty and Time Deviation (1)
3.3 Delivery method (2)
4 Metrological standards (3)
4.1 Name and magnitude (3)
4.2 Frequency deviation and time deviation (3)
4.3 Transfer method (3)
5 Work measuring instruments (4)
5.1 Name and measurement range of typical work measuring instruments (4)
5.2 Frequency deviation and time deviation of work measuring instruments (4)
6 time frequency measurement equipment inspection system table (5)
Introduction
The test system table is based on JJF1001-2011 "General measurement terms and definitions", JJF1104-2003 "country
Home measurement system to prepare the rules of the system "and JJF1002-2010" national measurement procedures for the preparation of rules "as the basis
Revised JJG 2007-2007.
Compared with JJG 2007-2007 "time frequency measurement instrument verification system table", in addition to editorial changes, the main
The technical content has the following changes.
- no longer use the concept of frequency accuracy, use frequency uncertainty at the reference level, standard and work metering
Appliances use the maximum allowable frequency deviation;
- the measurement of the base name and technical indicators were revised;
In the measurement reference transmission method, direct measurement is added to the frequency offset comparator method for frequency transmission.
Transmission to supplement the satellite bidirectional time frequency transmission and fiber time frequency transfer method;
--- added the atomic time standard;
In the metrological standard delivery method, the time frequency remote transmission method is supplemented. For the direct measurement of frequency
The time difference measuring instrument and the phase meter method;
--- Work Metering Appliances Added GNSS Receiver, GNSS Signal Simulator.
This test system table version of the previous release.
--- JJG 2007-2007;
--- JJG 2007-1987.
Time and frequency measuring instruments
1 Scope
The calibration system table is suitable for time frequency magnitude transmission, including the time frequency value from the time frequency measurement reference pass
The measurement relationship between the measurement standard and the working measuring instrument, the method of measuring the value and the measurement ability when the value is transmitted. In the open
Exhibition calibration, but also as a basis for the value of traceability.
2 reference file
Standard Terminology and Definitions for JJF1001
Evaluation and Representation of Measurement Uncertainty JJF1059.1-2012
JQF1180 Terminology and definition of time and frequency nouns
Where the date of the reference file, only the date of the version applies to the system table, all do not note the date of the reference text
, The latest version (including all modifications) applies to this system.
3 measurement basis
3.1 name and value
The time-frequency measurement base includes the seconds-length national measurement basis (hereinafter referred to as the second-length basis) and the atomic time-scale national meter
The benchmark (hereinafter referred to as the atomic time scale reference).
3.1.1 seconds long baseline
The seconds long datum is directly reproduced in seconds defined by the physical device, currently for the NIM5 laser cooled cesium atom fountain clock, the main
To use.
1) participation in international atomic generation;
2) Direct calibration of the atomic time scale reference seconds.
The output frequency of the second reference is 9192631770Hz.
3.1.2 atomic time scale reference
The atomic time scale is composed of a set of continuously working atomic clocks, internal alignment systems and external alignment systems.
Global Navigation Satellite System (GNSS) Time Frequency Transmission and Satellite Bidirectional Time Frequency Transfer (TWSTFT) Participation
International Bureau of Metrology (BIPM) organized by the International Atomic Time (TAI) to establish and maintain standard time, code-named
UTC (NIM).
UTC (NIM) gives 5MHz, 10MHz and 100MHz standard frequency signals, 1PPS standard time
Signal and Beijing time.
Note. The Global Navigation Satellite System (GNSS) currently includes GPS in the United States, GLONASS in Russia, Galileo in the European Union
And China 's BDS (Big Dipper).
3.2 Frequency Uncertainty and Time Deviation
3.2.1 seconds long reference frequency uncertainty
Multiple physical and technical factors cause the frequency of the second basis of the frequency of the complex value deviation from the definition value. To assess the various factors
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 2007-2015_English be delivered?Answer: Upon your order, we will start to translate JJG 2007-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 2007-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJG 2007-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 2007-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2007-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|