HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1112-2015 English PDF

US$599.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1112-2015: Testers for Relaying Protection
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1112-2015English599 Add to Cart 5 days [Need to translate] Testers for Relaying Protection Valid JJG 1112-2015

PDF similar to JJG 1112-2015


Standard similar to JJG 1112-2015

JJF 1234   JJG 376   JJF 1107   JJG 1115   JJG 1120   JJG 1106   

Basic data

Standard ID JJG 1112-2015 (JJG1112-2015)
Description (Translated English) Testers for Relaying Protection
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Word Count Estimation 26,288
Date of Issue 2015-04-10
Date of Implementation 2015-07-10
Regulation (derived from) State Quality Inspection Administration Announcement 2015 No. 47
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJG 1112-2015: Testers for Relaying Protection

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Testers for Relaying Protection National Metrological Verification Regulation of the People's Republic of China Relay protection tester 2015-04-10 released 2015-07-10 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Relay protection tester Verification procedures Protection Unit. National Electromagnetic Metrology Technical Committee High Pressure Metering Subcommittee The main drafting unit. Shandong Institute of Metrology State Grid Sichuan Electric Power Company National high voltage metering station Participated in the drafting unit. Shanghai Electric Power Company Electric Power Research Institute This procedure is entrusted to the National Electromagnetic Metrology Technical Committee of the High Pressure Metrology Subcommittee. The main drafters of this procedure. Yang Mei (Shandong Institute of Metrology) Ding Dan one (State Grid Sichuan Electric Power Company) Li Wenqiang (Shandong Institute of Metrology) Xiang Qiong (National High Voltage Metering Station) Participate in the drafters. Lu Youlong (Shanghai Electric Power Company Electric Power Research Institute) Li Min (State Grid Sichuan Electric Power Company) Wang Xinyan (Shandong Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 terms and units of measurement (1) 3 Overview (1) 4 Measurement performance requirements (1) 4.1 Accuracy class (1) 4.2 Basic error (1) 4.3 Response time (2) 4.4 Other performance indicators (3) 4.5 AC current source and AC voltage source synchronization (3) 4.6 Phase control of AC current source and AC voltage source (3) 4.7 Time measurement (3) 4.8 DC output (4) 5 General technical requirements (4) 5.1 appearance and normal work inspection (4) 5.2 Insulation requirements (4) 5.3 Functional check (4) 6 Metering device control (5) 6.1 Test conditions (5) 6.2 Verification Project (5) 6.3 Test method (6) 6.4 Processing of test results (13) 6.5 Test period (13) Appendix A Verification of the original record format (14) Appendix B Verification Certificate/Verification Result Notification Page Format (Page 2) (17) APPENDIX C INSPECTION CERTIFICATE/QUALIFICATION RESULTS Notice Page Format (page 3) (18)

Introduction

This procedure is based on JJF1001-2011 "General Metrology Terms and Definitions", JJF1002-2010 "National Metrology Verification rules to prepare rules "to develop. The procedures to GB/T 7261-2008 "relay protection and safety automatic device basic test method", DL/T 624- 2010 "relay protection microcomputer test device technical conditions" based on the development. This order is the first release. Test procedure for relay protection tester

1 Scope

This procedure applies to the microcomputer-based relay protection tester (hereinafter referred to as the tester) the basic functions and measurement performance of the first Sub-test, follow-up test and use of inspection.

2 terms and units of measurement

2.1 closing phase angle closingphaseangle The amount of AC excitation applied to the relay at the moment of closing, protection and safety of the automatic device voltage (or current) Phase angle. 2.2 Response time responsetime Voltage or current value from 10% to 90% or 90% to 10% of the time required.

3 Overview

Testers generally by the power supply, control part, current amplifier, voltage amplifier, auxiliary DC voltage, out Quantity, the amount of imports and other components, is the relay protection sampling accuracy, action principle, action time to test instrument. Tester control voltage amplifier, current amplifier output voltage, current, out of the output contact to the relay Protection, by the control part of the control output current, voltage amplitude, phase, frequency, open the amount of opening and closing simulation of various tests Test logic process, according to the relay protection action information and action contacts return to the tester into the amount of the situation, record the relay Protected action value and action time.

4 Measurement performance requirements

4.1 Accuracy class The tester is divided into two levels. 0.1 (where AC ± 0.1%, DC ± 0.2%) and 0.2 (where AC ± 0.2%, DC ± 0.5%). 4.2 Basic error The flow voltage is 2V U≤Umax、时间T 1s, the basic error of the tester is expressed by relative error, such as the public As shown in equation (1). γ = xx-xn xn x 100% (1) Where. γ --- the relative error of the measured value of the test instrument,%; xx --- detected test instrument display value; xn --- test standard indication.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1112-2015_English be delivered?

Answer: Upon your order, we will start to translate JJG 1112-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1112-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1112-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.