US$419.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1075-2012: Verification Regulation of High Voltage Standard Capacitors Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1075-2012 | English | 419 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of High Voltage Standard Capacitors
| Valid |
JJG 1075-2012
|
PDF similar to JJG 1075-2012
Basic data Standard ID | JJG 1075-2012 (JJG1075-2012) | Description (Translated English) | Verification Regulation of High Voltage Standard Capacitors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 17.220 | Word Count Estimation | 18,116 | Quoted Standard | JJG 496-1996; JJG 563-2004; GB/T 16927.1 | Regulation (derived from) | AQSIQ Announcement No. 35 of 2012 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the rated frequency of 50 (60) Hz, rated voltage of 10kV and above shielded high voltage standard capacitor electrode structure of the initial verification, testing and use of follow-up checks. |
JJG 1075-2012: Verification Regulation of High Voltage Standard Capacitors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of High Voltage Standard Capacitors
State verification procedures People's Republic of China
High voltage standard capacitor
Issued on. 2012-03-02
2012-06-02 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
High voltage standard capacitor
Verification Regulation
acitors
Focal point. the National Technical Committee on Electromagnetic measurement
The main drafting units. the national high voltage metering station
Hubei Electric Power Company Electric Power Research Institute
Xinjiang Institute of Metrology
Participated in the drafting unit. Sichuan Electric Power Research Institute
Anhui Electric Power Research Institute
Haisi Electrical Equipment Co., Ltd.
The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic
The main drafters of this procedure.
Wangle Ren (the national high voltage metering station)
Item Joan (the national high voltage metering station)
Wang Yongqin (Electric Power Research Institute Hubei Electric Power Company)
Zhang Song Qiang (Xinjiang Institute of Measurement and Testing)
Drafters participate.
Yuan Heng (Sichuan Electric Power Research Institute)
Zhu Qi (Anhui Electric Power Research Institute)
Zhu Bin (Haisi Electrical Equipment Co., Ltd.)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 metering performance requirements (1)
Capacitance error 4.1 (1)
4.2 Dissipation Factor (1)
4.3 voltage coefficient (2)
4.4 included a capacitive voltage divider (2)
4.5 Stability (2)
5 General Requirements (2)
5.1 Nameplate, terminals and marking (2)
5.2 dielectric strength (2)
5.3 pressure gauge (3)
5.4 protection device (3)
6 Control of measuring instruments (3)
6.1 Verification condition (3)
6.2 Verification Project (4)
6.3 Verification Methods (4)
Processing 6.4 Verification Results (6)
6.5 test cycle (6)
Appendix A test original record format (7)
Appendix B test certificates/test results in the notice page format (9)
Introduction
This procedure based on JJF1002-2010 "national verification procedures write rules" establishment.
This procedure uses a reference JB1811-1992 "compressed gas capacitor" relevant compressed gas capacitor measurability
Energy requirements and with JJG 496-1996 "frequency high voltage divider" has been promulgated, JJG 563-2004 "high-voltage
Yung bridge ", JJG 1021-2007" power transformer "and JJG 314-2010" measuring voltage transformer "phase
coordination.
This procedure is the first national verification procedures developed.
High voltage standard capacitor test procedures
1 Scope
The order applies to the nominal frequency of 50 (60) Hz, rated voltage of 10kV or more, and the shield electrode structure
High voltage standard capacitor initial verification, subsequent verification and the use of checks.
2. References
This procedure refers to the following documents.
JJG 496-1996 frequency high voltage divider
JJG 563-2004 high voltage capacitance bridge
GB/T 16927.1 High-voltage test techniques Part 1. General test requirements
For dated references, only the edition applies to the procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 Overview
High voltage standard capacitor is stability of capacitance and dissipation factor of the order of 10-4 or more have reached a high voltage precision
Capacitors. Its structure includes a high voltage electrode with a metal electrode material, electrode and a shielding electrode measurements, it must
Edge structure includes supporting the high voltage electrode and the insulation of high voltage electrode and the shield electrode holder fixed measurement. gas
Insulated high voltage standard capacitor electrode sealed in a pressure vessel, the vessel is filled with SF6, N2, CO2 such must
Edge of the gas; standard insulated high voltage electrode is vacuum sealed in a container capacitor in a high vacuum. Loss of tiny solid and
Liquid materials may also be used as a standard high-voltage capacitor dielectric.
High voltage standard capacitor of the most important performance measurement of electrical capacity and the loss factor and the operating voltage correlation
(Referred to as the voltage coefficient) is extremely small, the order of 10-5 to reach. Therefore their capacity and dissipation factor can be lower
Voltage (for example, 10% of the rated voltage) calibration, and then under a high voltage as capacitance and loss factor of the standard device
use.
4 metering performance requirements
4.1 capacitance error
Under reference conditions shown in Table 1, the high voltage standard capacitor capacitance found on the nameplate or certificate given nominal capacitance
Deviation shall not exceed ± 0.3%.
NOTE. When the nameplate value with a valid certificate value inconsistent with a valid certificate values prevail. Articles in the case of the following nameplate value with a valid certificate
They are treated similarly inconsistent values.
4.2 Loss Factor
The nominal reference conditions in table 1, high voltage standard capacitor loss factor found on the nameplate or certificate given
Loss of value due to deviation shall not exceed ± 1 × 10-4.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1075-2012_English be delivered?Answer: Upon your order, we will start to translate JJG 1075-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1075-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1075-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|