US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1072-2011: Verification Regulation of High Voltage and Value D.C.Resistors Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1072-2011 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of High Voltage and Value D.C.Resistors
| Valid |
JJG 1072-2011
|
PDF similar to JJG 1072-2011
Basic data Standard ID | JJG 1072-2011 (JJG1072-2011) | Description (Translated English) | Verification Regulation of High Voltage and Value D.C.Resistors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 47.220 | Word Count Estimation | 19,171 | Date of Issue | 2011-11-30 | Date of Implementation | 2012-05-30 | Older Standard (superseded by this standard) | JJG 166-1993 | Quoted Standard | JJF 1001; JJF 1059; JJF 1094; JB/T 8225-1999 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine No. 202 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to maximum nominal operating voltage greater than 1kV, the total resistance is greater than 10M�� DC high voltage high value resistors (hereinafter referred to as high-pressure high-impedance device) the initial verification, testing and use of follow-up checks. This procedure does not apply to active and passive analog resistor, does not apply to permanently installed in the circuit as a resistor element. |
JJG 1072-2011: Verification Regulation of High Voltage and Value D.C.Resistors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of High Voltage and Value DCResistors
State verification procedures People's Republic of China
DC high voltage high value resistor
Issued on. 2011-11-30
2012-05-30 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
DC high voltage high value resistor
Verification Regulation
Resistors
Replacing JJG 166-1993
(DC high voltage high value
Resistor section)
Focal point. the National Technical Committee on Electromagnetic measurement
Drafted by. Shandong Electric Power Research Institute
China Institute of Metrology
Heilongjiang Provincial Institute of Metrology
The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic
The drafters of the regulations.
Fanqiao Cheng (Shandong Electric Power Research Institute)
Shao Haiming (China Institute of Metrology)
Yang Wei (Heilongjiang Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 metering performance requirements (1)
4.1 Accuracy class and maximum permissible error (1)
Voltage variation 4.2 (2)
4.3 Residual Resistance (2)
4.4 switch contact resistance variation (2)
5 General Requirements (2)
5.1 Appearance and identification (2)
5.2 Structure (2)
5.3 Insulation resistance (3)
5.4 frequency voltage withstand test (3)
5.5 temperature, relative humidity nominal conditions of use (3)
6 Control of measuring instruments (3)
6.1 Verification condition (3)
6.2 test items and test methods (4)
6.3 Verification Results Processing (5)
6.4 test cycle (6)
Appendix A DC high voltage high value resistor measuring principle (7)
Appendix B test original record format (9)
C calibration certificate/test results in the notice page format Shape appendix (11)
Introduction
JJF1002-2010 "national verification procedures to write rules" rules of order preparation is based.
JJG 1072-2011 "DC high voltage high value resistor" is JJG 166-1993 "DC resistance" for the group
Foundation, on which the DC high voltage high value resistor (hereinafter referred to as high-pressure high-impedance device) amended section and separate developed
Test procedures. Compared with JJG 166-1993, the main technical changes are as follows.
--- The order applies to the use of a nominal voltage greater than 1kV, the total resistance is greater than 10MΩ the high-pressure high-impedance detection
Set (see 1);
--- Zero switching device block at high-pressure high-impedance device, when all the switches are set to zero, the output of the residual power
Direct resistance shall not be greater than 1Ω (see 4.3);
--- High-voltage switching device with a high impedance device, the resistance caused by the deterioration of the contact switch contacts shall not be greater than the direct
0.1Ω (we see 4.4);
--- Clear nominal operating voltage (or current) (see 5.1);
--- Emphasized the high voltage high impedance device should be placed at least 24 hours at reference conditions, so that the internal temperature and humidity
Consistent with the environment (see 6.1.2);
--- Simplifies the residual resistance measurement and switch contact resistance variation calculation (see 6.2.2.4,6.2.2.5);
--- Basic error of measurement is given using op amps partial pressure method, the partial pressure method and bridge method three measurement principle (see Annex
Record A);
--- Resistance value rounding interval regulations have been simplified (see 6.3.2);
--- Increasing the "verification original record format" (see Appendix B), and "verification certificate and test results notice
The inside pages Format "(see Appendix C).
DC high voltage high value resistor test procedures
1 Scope
DC high voltage electrical high value of the order applies to the use of the maximum nominal voltage greater than 1kV, the total resistance is greater than 10MΩ
Resistor (hereinafter referred to as high-pressure high-impedance device) initial verification, use and subsequent verification check.
This procedure does not apply to active and passive analog resistor in the circuit is not suitable for installation as a permanent element
Resistor.
2. References
This procedure refers to the following documents.
JJF1001 common measurement terms and definitions
JJF1059 Evaluation and Expression of Uncertainty in Measurement
JJF1094 measuring instrument characteristics evaluation
JB/T 8225-1999 Laboratory DC resistor
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 Overview
High voltage high impedance is high impedance and how the value of the high-pressure single-valued high-pressure high-impedance device, mainly used for insulation resistance meter (megger)
Verification. Multi-value high-pressure high-impedance typically consists of several decade resistor pad series, each of the disc by the decimal equivalent resistance
Single-value resistor and step switch composed of not less than the minimum step resistance 100Ω; part of a multi-valued uses high-pressure high-impedance end
Button-type structure, or a combination of the above two forms.
4 metering performance requirements
4.1 accuracy class and the maximum permissible error
At reference conditions, high voltage high impedance device each decade resistor pad or button on each side can have its own resistor accuracy, etc.
Level and the nominal operating voltage.
High voltage high impedance device each decade resistor pad or button on each end resistance corresponding accuracy class and the maximum permissible errors shall be
Specified in Table 1.
Table 1 Accuracy class and maximum permissible error
Accuracy class 0.2 0.5 Level 1 Level 2 510
The maximum permissible error ± 0.2% ± 0.5% ± 1% ± 2% ± 5% ± 10%
High voltage high impedance indication error by the relative error, said.
δ = Rn-RxRx × 100%
(1)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1072-2011_English be delivered?Answer: Upon your order, we will start to translate JJG 1072-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1072-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1072-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|