JJG 1029-2007: Verification Regulation of Vortex-shedding Flowmeter
Status: Valid

JJG 1029: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1029-2007English499 Add to Cart 4 days [Need to translate] Verification Regulation of Vortex-shedding Flowmeter Valid JJG 1029-2007
JJG 1029-1991EnglishRFQ ASK 3 days [Need to translate] The norm for development of certified reference materied used in quantitative analysis of electron microprobe Obsolete JJG 1029-1991

PDF similar to JJG 1029-2007


Standard similar to JJG 1029-2007

GB/T 36126   JJG 1030   GB/T 1885   JJG 1036   JJG 1035   JJG 1020   

Basic data

Standard ID JJG 1029-2007 (JJG1029-2007)
Description (Translated English) Verification Regulation of Vortex-shedding Flowmeter
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.120
Word Count Estimation 19,141
Date of Issue 2007-08-21
Date of Implementation 2007-11-21
Older Standard (superseded by this standard) JJG 198-1994
Quoted Standard AQSIQ Announcement No. 142 of 2007
Regulation (derived from) AQSIQ Announcement No. 142 of 2007
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the vortex flowmeter type evaluation, initial verification, testing and use of follow-up inspection.

JJG 1029-2007: Verification Regulation of Vortex-shedding Flowmeter

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Vortex-shedding Flowmeter State verification procedures People's Republic of China Vortex Flowmeter Posted 2007-08-21 2007-11-21 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Vortex flowmeter test procedures Vortex-shedding Flowmeter In place of JJG 198-1994 Vortex flow section The regulations by the State Administration of Quality Supervision, Inspection and Quarantine August 21, 2007 approved and From November 21, 2007 into effect. Focal point. the National Technical Committee on Metering flow capacity The main drafting units. China Institute of Metrology Beijing Institute of Metrology detection Participated in the drafting unit. Liaoning Provincial Institute of Metrology Dalian Long Instrument Company Beijing Fisher Porter Instrument Company Tianjin billion Central Automation Instrumentation Company Shanghai Yokogawa Electric Co., Ltd. Emerson Process Management This procedure flow capacity commissioned the National Technical Committee on Metering explain The main drafters of this procedure. Huiming paragraph (China Institute of Metrology) Yangyou Tao (Beijing Institute of Metrology detection) Drafters participate. Mei Chen (Liaoning Provincial Institute of Metrology) Sun Huachun (Dalian Long Instrument Company) Wang Yue sound (Beijing Fisher Porter Instrument Company) Liu Zhonghai (Tianjin billion Central Automation Instrumentation Company) Zhao Zhiliang (Shanghai Yokogawa Electric Co., Ltd.) Item Zi Liang (Emerson Process Management)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Terms (1) 4 Overview (2) 4.1 Purpose and works (2) 4.2 composition and output (2) 5 metering performance requirements (2) 5.1 accuracy class (2) 5.2 Repeatability (2) 6 General Requirements (2) 6.1 random file (2) 6.2 Identification and plate (3) 6.3 Appearance (3) 6.4 Protection (3) Tightness 6.5 (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 test items and test methods (5) 7.3 test result processing (8) 7.4 test cycle (8) Appendix A pattern evaluation outline (9) Appendix B test certificate and test results notice (inside) information (14) Vortex flowmeter test procedures

1 Scope

The order applies to the vortex flowmeter (hereinafter referred to as meter) of pattern evaluation, initial verification, verification and follow-up Use the test.

2 Citations

The provisions of the following standards, procedures included by reference, constitute provisions of this Directive. JJF1001-1998 common measurement terms and definitions JJF1004-2004 flow measurement terminology and definitions GB 17820-1999 Natural Gas GB 50251-2003 pipeline engineering design GB/T 13609-1999 Natural Gas sampling guidelines GB/T 13610-2003 gas composition analysis by gas chromatography GB/T 17747.2-1999 gas - Calculation of compression factor - Part 2. calculation of molar composition GB 3836.1-2000 Electrical equipment for explosive gas atmospheres - Part 1. General requirements GB 3836.2-2000 Electrical equipment for explosive gas atmospheres - Part 2. flameproof "d" GB 3836.3-2000 Electrical equipment for explosive gas atmospheres Part 3. Increased Safety "e" OIMLD25-1996Vortexmetersusedinmeasuringsystemsforfluids Note that using the currently valid version of the documents cited.

3 Terms

In addition to this regulation cited JJF1001-1998, JJF1004-2004 terms and definitions, but also use the following the term. 3.1 vortex shedder (bluffbody) Generating bluff body vortex. 3.2 probe (sensor) After detecting Baffles fluid vortex vibration frequency components. 3.3 Body (meterbody) Setting Pipe Baffles segment and probes. 3.4 K coefficient (K-cofficient) Unit volume of fluid flow through the meter, the number of pulses emitted by the flow meter. 3.5 flow regulator (flowconditioner) It can reduce the vortex velocity and improving parts distribution. 3.6 meter factor (meterfactor) Flowmeter for actual flow test, according to the results of the meter indication correction coefficient. Its value is shown in the standard device

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1029-2007_English be delivered?

Answer: Upon your order, we will start to translate JJG 1029-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1029-2007_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1029-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 1029-2007?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1029-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.