JJG 1005-2019English419 Add to Cart 4 days [Need to translate] Electronic Insulation Resistance Meters Valid JJG 1005-2019
JJG 1005-2005English599 Add to Cart 3 days [Need to translate] Verification Regulation of Electronic Insulating Resistance Meters Obsolete JJG 1005-2005
JJG 1005-1986EnglishRFQ ASK 3 days [Need to translate] General Terms of Reference Material Obsolete JJG 1005-1986

PDF similar to JJG 1005-2019


Standard similar to JJG 1005-2019

JJF 1234   JJG 376   JJF 1107   JJF 2001   JJF 2000   JJF 1005   

Basic data

Standard ID JJG 1005-2019 (JJG1005-2019)
Description (Translated English) Electronic Insulation Resistance Meters
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.220.20
Word Count Estimation 19,178
Date of Issue 2019
Date of Implementation 2020-03-31
Issuing agency(ies) State Administration for Market Regulation

JJG 1005-2019: Electronic Insulation Resistance Meters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Verification Regulation of Electronic Insulation Resistance Meter) National Measurement Verification Regulations of the People's Republic of China Electronic insulation resistance meter Published on December 31,.2019 2020-03-31 Implementation Issued by the State Administration of Market Supervision and Administration Electronic insulation resistance meter Verification regulations Replace JJG 1005-2005 Centralized unit. National Electromagnetic Measurement Technical Committee Main drafting unit. National High Voltage Measuring Station Chinese Academy of Metrology Yichang Metrology Verification Test Institute Participated in the drafting unit. State Grid Hubei Electric Power Company Electric Power Research Institute Liaoning Institute of Metrology Wuhan Kangda Electric Co., Ltd. This regulation is entrusted to the National Electromagnetic Measurement Technical Committee for interpretation The main drafters of this regulation. Zhang Jun (National High Voltage Metering Station) Wang Siqi (National High Voltage Metering Station) Liang Bo (Chinese Academy of Metrology) Chen Yu (Yichang Metrology Verification Test Institute) Participating drafters. Shen Li (State Grid Hubei Electric Power Company Electric Power Research Institute) Liang Guoding (Liaoning Institute of Metrology) Hu Xiaohui (Wuhan Kangda Electric Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terminology (1) 3.1 Insulation resistance (1) 3.2 Measuring terminal (1) 3.3 Terminal voltage (1) 3.4 Rated voltage (1) 3.5 Open circuit voltage (1) 3.6 Drop resistance (1) 3.7 Drop voltage (1) 4 Overview (1) 5 Measurement performance requirements (2) 5.1 Accuracy level and maximum allowable error (2) 5.2 Terminal voltage and allowable range (4) 6 General technical requirements (4) 6.1 Appearance and marking (4) 6.2 Electrical safety performance (4) 7 Control of measuring instruments (5) 7.1 Verification conditions (5) 7.2 Measurement standard used in verification (5) 7.3 Verification items (5) 7.4 Verification method (6) 7.5 Processing of verification results (8) 7.6 Verification period (8) Appendix A Verification of Original Record Format (9) Appendix B Format of the inner pages of the certificate of verification/certification result (11) Appendix C Verification Certificate/Verification Result Notification Verification Results Page Form (Page 3) (12)

Introduction

This regulation is a revision of JJG 1005-2005 "Electronic Insulation Resistance Meter Verification Regulations". With JJG 1005- Compared with.2005, except for editorial changes, the changes in the relevant technical parts are as follows. ---Insulation resistance inspection process increased to 1TΩ; --- Adjusted the description in the "Overview" section, the display mode has added digital, pointer dual display and other modes; ---In the measurement performance requirements, the pointer shows the accuracy section of the insulation meter and the maximum allowable error The requirements of the accuracy section of the digital display insulation table have been improved; ---In the measurement performance requirements, the measurement pointer no longer shows the "median voltage" of the insulation resistance meter, but is unified Use open circuit voltage and drop voltage to verify the terminal voltage of the pointer display and digital insulation resistance meter, unifying the terminals Voltage range requirements; --- In the control of measuring instruments, the requirements for the structure of high-voltage and high-resistance standard devices in the verification equipment have been cancelled, and it is clear The requirement for the internal resistance of the voltage measuring device has been removed from the "short circuit current" verification item. Previous releases of JJG 1005. ---JJG 1005-2005. Verification Regulation of Electronic Insulation Resistance Meter

1 Scope

This regulation is applicable to electronic insulation resistance meters with a measuring range not greater than 1TΩ and a rated voltage of 10kV and below (Hereinafter referred to as "insulation meter") the first verification, subsequent verification and inspection in use. This regulation is not applicable to direct-acting analog indication, mechanical type and insulation resistance meters and high resistance meters with special requirements Test.

2 Reference documents

This regulation refers to the following documents. JJG 622 Insulation Resistance Meter (Megohmmeter) For dated references, only the dated versions are applicable to this Regulation; for those without dates The latest version (including all amendments) is applicable to this regulation.

3 Terminology

3.1 Insulation resistance insulation resistance The ratio of the value of the DC voltage applied between the two electrodes of the insulating structure to the value of the leakage current flowing through the pair of electrodes. 3.2 Test terminal testterminal Terminals used to connect the measured object in the insulation table. The measurement terminal is connected to the connection part of the measured object, Divided into line terminal L, ground terminal E and shield terminal G. 3.3 Terminal voltage The voltage between the line terminal L and the ground terminal E of the insulation meter. 3.4 Rated voltage ratedvoltage (U0) The nominal value of the terminal voltage when the measuring terminal is open. 3.5 open-circuit voltage The insulation meter measures the terminal voltage measured when the terminal is open. 3.6 Fal-offresistance When measuring the drop voltage of the insulation meter, connect the resistance of the measurement terminal of the insulation meter. 3.7 Fal-offvoltage The terminal voltage when the drop resistance is connected between the line terminal L and the ground terminal E of the insulation meter reflects the insulation meter With load capacity.

4 Overview

The insulation meter is powered by a battery or an external power supply. Its basic principle is shown in Figure 1.DC/ through electronics DC conversion provides measurement voltage to the measurement terminals L and E. The electronic circuit composed of CPU, operational amplifier, ADC, etc. The circuit converts or processes the measured signal and directly indicates or displays the measured insulation resistance by the magnetoelectric system ammeter or digital meter