US$509.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1003-2016: Flow Integration Meters Status: Valid JJG 1003: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1003-2016 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
Flow Integration Meters
| Valid |
JJG 1003-2016
|
JJG 1003-2005 | English | 879 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Intergration Meters
| Obsolete |
JJG 1003-2005
|
PDF similar to JJG 1003-2016
Basic data Standard ID | JJG 1003-2016 (JJG1003-2016) | Description (Translated English) | Flow Integration Meters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Word Count Estimation | 22,243 | Date of Issue | 2016-11-25 | Date of Implementation | 2017-05-25 | Older Standard (superseded by this standard) | JJG 1003-2005 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine Notice No.116 of 2016 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine |
JJG 1003-2016: Flow Integration Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Flow Integration Meters
National Metrological Verification Regulation of the People's Republic of China
Flow totalizer
2016-11-25 release
2017-05-25 implementation
State Administration of Quality Supervision, Inspection and Quarantine issued
Verification of flow totalizer
Replacing JJG 1003-2005
Responsible Unit. National Traffic Capacity Measurement Technical Committee
The main drafting unit. Henan Institute of Metrology
National Water Meter Quality Supervision and Inspection Center
Participated in the drafting unit. China Institute of Metrology
Beijing Bo Sida New Century Measurement and Control Technology Co., Ltd
Anhui Institute of Metrology
Zhengzhou City Thermal Corporation
This procedure entrusts the National Flow Capacity Measurement Technical Committee to explain
The main drafters of this procedure.
Zhu Yonghong (Henan Institute of Metrology)
Zhou Wenhui (Henan Institute of Metrology)
Yan Jiwei (National Water Meter Quality Supervision and Inspection Center)
Participate in the drafters.
Shi Zhendong (China Institute of Metrology)
Li Jian (Beijing Bo Sida New Century Measurement and Control Technology Co., Ltd.)
Sun Xiuliang (Anhui Institute of Metrology)
Wang Chengyuan (Zhengzhou City Thermal Power Corporation)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Terms (1)
3.2 Units of measurement (2)
4 Overview (2)
4.1 Working principle (2)
4.2 Structure (2)
4.3 Flow signal input form (2)
4.4 supporting instrumentation signal input form (2)
5 Metrological performance requirements (3)
6 General technical requirements (3)
6.1 General technical requirements (3)
6.2 Other technical requirements (4)
7 Metering device control (4)
7.1 Test conditions (4)
7.2 Verification Project (5)
7.3 Verification method (5)
7.4 Processing of test result (7)
7.5 Verification cycle (7)
Appendix A common flow formula and media properties of the parameters of the provisions (8)
Appendix B Verification Record Format (13)
APPENDIX C INSPECTION CERTIFICATE/CERTIFICATION RESULTS The information and format (15)
Introduction
This procedure to GB/T 13639-2008 "industrial process measurement and control system with analog input digital instructions
"GB/T 2624-2006" Measurement of full-pipe fluid flow with differential pressure devices installed in circular cross-section pipes "is
Technical basis, combined with the flow of our total production and use of the status quo, the JJG 1003-2005 "flow total
Instrument "to be revised. In the main technical indicators equivalent to the national standard. Compared with JJG 1003-2005, this regulation
In addition to editorial changes, the main technical changes are as follows.
--- increase the definition of flow totalizer;
--- increase the definition of quantitative control;
- the input form of the flow signal increases the digital signal;
--- increase the trade settlement with the total flow meter total technical requirements;
--- remove the insulation resistance and dielectric strength;
--- modified the selection of test points;
--- increase the instantaneous heat and cumulative calorie test method;
- the deletion of the original program in Appendix A "type evaluation test outline";
- the part of the provisions of Appendix B, "Selection of Measurement Parameters in Flow Error Test", in the original procedure
content;
--- modified part of the original procedure Appendix C "Verification Format";
--- Amend the contents of the original procedure Appendix D "Verification Certificate and Verification Result Notice Page Format".
Prerequisites of this Code Release.
--- JJG 1003-2005.
Verification of flow totalizer
1 Scope
This procedure applies to the flow of the totalizer (hereinafter referred to as the total instrument) of the first test, follow-up test, use
an examination.
Other flow integration devices with integral calculator function can refer to this procedure.
2 reference file
This procedure refers to the following documents.
On - line Gas Chromatograph
GB/T 2624-2006 Measurement of full flow of fluid with differential pressure devices installed in circular cross-section piping
Environmental testing of electronic measuring instruments GB 6587-1989
GB/T 11062 Calculation method of natural gas calorific value, density, relative density and Wobbe index (mod
ISO 6976)
Analogue input digital indicator for industrial process measurement and control systems GB/T 13639-2008
GB/T 17747 Calculation of natural gas compression factor (idtISO 12213)
GB/T 18603 Natural gas metering system technical requirements
Measurement of natural gas flow with standard orifice flowmeter GB/T 21446-2008
Heat meters for CJ128-2007
JB/T 2274-2014 flow display instrument
For dated references, only the dated edition applies to this rule; references that are not dated
, The latest version (including all amendments) applies to this procedure.
3 terms and units of measurement
3.1 terminology
By collecting the flow-related sensor signals, calculate the flow (energy) with the relevant mathematical model.
Set. Usually also known as flow display, flow computer and so on. With its matching sensors usually have standard throttle devices,
Turbines, vortex, electromagnetic, ultrasonic flow sensors or transmitters and other compensation with the pressure transmitter, differential pressure transmitter,
Temperature transmitter, component analyzer and so on.
3.1.2 power off protection poweroutageprotection
Totalizer in the power supply during power outage, totalizer set parameters and totalizer cumulative flow and other data can be reliable
Save the function.
3.1.3 sampling period samplingperiod
The interval between two adjacent samples.
3.1.4 small signal cutoff lowflowratecutoff
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1003-2016_English be delivered?Answer: Upon your order, we will start to translate JJG 1003-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1003-2016_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1003-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 1003-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1003-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|