JJF 4.5-2010 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 4.5-2010EnglishRFQ ASK 3 days [Need to translate] Tobacco and Tobacco Products. Evaluation of Uncertainty in Measurement for Routine Chemical Ingredients Using Continuous Flow Method. Part 3: Total Nitrogen JJF 4.5-2010

Standard similar to JJF 4.5-2010

JJG 4   JJF 4.2   JJF 4.1   

Basic data

Standard ID JJF 4.5-2010 (JJF4.5-2010)
Description (Translated English) Tobacco and Tobacco Products. Evaluation of Uncertainty in Measurement for Routine Chemical Ingredients Using Continuous Flow Method. Part 3: Total Nitrogen
Sector / Industry Metrology & Measurement Industry Standard
Date of Issue 2010-12-27
Date of Implementation 2011-01-15
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 4.5-2010: Tobacco and Tobacco Products. Evaluation of Uncertainty in Measurement for Routine Chemical Ingredients Using Continuous Flow Method. Part 3: Total Nitrogen


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Tobacco and Tobacco Products.Evaluation of Uncertainty in Measurement for Routine Chemical Ingredients Using Continuous Flow Method.Part 3. Total Nitrogen Ministry of People's Republic of China Metrology Technical Specifications JJF (Tobacco) 4.5-2010 Continuous flow of tobacco and tobacco products Determination of conventional chemical composition measurement uncertainty Degree assessment guide Part 5. Potassium Part 5. Potassium Released on.2010-12-27 2011-01-15 implementation National Tobacco Monopoly Bureau released Continuous flow of tobacco and tobacco products Determination of conventional chemical composition measurement uncertainty Degree assessment guide Part 5. Potassium EvaluationofUncertaintyinMeasurementfor RoutineChemicalIngredientsUsing ContinuousFlowMethod- Part 5. Potassium JJF (Tobacco) 4.5-2010 This specification was approved by the State Tobacco Monopoly Bureau on December 27,.2010, and since January.2011 Implemented on the 15th. Focal Point. National Tobacco Monopoly Bureau Main drafting unit. National Tobacco Quality Supervision and Inspection Center Shanghai Tobacco (Group) Co., Ltd. Shenzhen Tobacco Industry Co., Ltd. Shandong China Tobacco Industry Co., Ltd. Technology Center Qingdao Workstation Jiangsu Zhongyan Industry Co., Ltd. Xuzhou Cigarette Factory Hongyun Honghe Tobacco (Group) Co., Ltd. This specification is interpreted by the National Tobacco Standardization Technical Committee. JJF (Tobacco) 4.5-2010 The main drafters of this specification. Wang Ying Chen Zaigen Participate in the drafters. Wang Lu Sui Dynasty Wang Xiaochun Stone red geese Zhang De JJF (Tobacco) 4.5-2010

table of Contents

1 Scope (1) 2 Citations (1) 3 Basic terms and concepts (1) 4 Mathematical models and uncertainty components (1) 5 synthetic standard uncertainty (6) 6 Extended uncertainty (6) Appendix A Standard Uncertainty Evaluation of Fitting Curve Parameters (7) JJF (Tobacco) 4.5-2010 Continuous flow of tobacco and tobacco products Determination of conventional chemical composition measurement uncertainty Degree assessment guide Part 5. Potassium

1 Scope

The uncertainty assessment procedure provided by this specification is used to guide the continuous flow measurement of tobacco and tobacco products. Evaluation of chemical composition potassium measurement uncertainty.

2 Citations

This specification refers to the following documents. JJF 1059 Measurement Uncertainty Evaluation and Representation YC/T 31 Preparation of tobacco and tobacco product samples and moisture determination oven method YC/T 217 Determination of potassium in tobacco and tobacco products - Continuous flow method Use of this specification should be done with the current valid version of the above cited documents.

3 basic terms and concepts

The relevant terms and definitions given in JJF 1059, YC/T 31, and YC/T 217 apply to this specification.

4 Mathematical models and uncertainty components

4.1 Mathematical model of the measurement process From YC/T 217, the mathematical model of the tested potassium of tobacco and tobacco products is shown in equation (1). POT=RPOT±RPOT× [urel(m)]2 [urel(W)]2 [urel(V)]2 [urel(C)]2 [urel(rep)]2 (1) In the formula. POT---potassium amount; RPOT---the measured value of potassium; Urel(m)---the relative amount of influence introduced by sample quality measurement; Urel(W)---the relative amount of influence introduced by sample moisture measurement; Urel(V)--the relative amount of influence introduced by the volume measurement of the extract; Urel(C)---the relative amount of influence introduced by sample concentration measurement; Urel(rep)---Measures the relative amount of influence introduced by repeatability. 4.2 Uncertainty component evaluation 4.2.1 Uncertainty component introduced by sample quality measurement, urel(m) JJF (Tobacco) 4.5-2010