| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| JJF 2153-2024 | English | 559 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Intense Pulsed Light Therapy Apparatuses
| Valid |
Basic data
| Standard ID | JJF 2153-2024 (JJF2153-2024) |
| Description (Translated English) | Calibration Specification for Intense Pulsed Light Therapy Apparatuses |
| Sector / Industry | Metrology & Measurement Industry Standard |
| Word Count Estimation | 27,216 |
| Date of Issue | 2024-09-18 |
| Date of Implementation | 2025-03-18 |
| Issuing agency(ies) | State Administration for Market Regulation |
JJF 2153-2024: Calibration Specification for Intense Pulsed Light Therapy Apparatuses
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Technical Specifications of the People's Republic of China
Intense pulsed light therapy device calibration specification
Released on 2024-09-18
2025-03-18 Implementation
The State Administration for Market Regulation issued
Intense pulsed light therapy device calibration specification
Responsible unit. National Medical Metrology Technical Committee
Main drafting unit. Jiangsu Institute of Metrology
China National Institute of Metrology
Participating in the drafting. Shanghai Institute of Metrology and Testing Technology
Jiangsu Provincial People's Hospital
This standard is entrusted to the National Medical Metrology Technical Committee for interpretation
The main drafters of this specification are.
Gu Jiayu (Jiangsu Institute of Metrology)
Hu Zhixiong (China National Institute of Metrology)
Li Jiao (China National Institute of Metrology)
Participating drafters.
Xia Ming (Shanghai Institute of Metrology and Testing Technology)
Pang Kan (Jiangsu Institute of Metrology)
Peng Mao (Jiangsu Provincial People's Hospital)
Gao Jianqiang (Shanghai Institute of Metrology and Testing Technology)
Table of contents
Introduction (II)
1 Scope(1)
2 References(1)
3 Terms and definitions (1)
4 Overview(2)
5 Metering characteristics (2)
5.1 Short wavelength boundary (2)
5.2 Transmitting window area (2)
5.3 Energy density (2)
5.4 Repeatability (3)
5.5 Reproducibility (3)
5.6 Uniformity (3)
5.7 Pulse width(3)
5.8 Pulse interval (if applicable) (3)
5.9 Pulse repetition time (if applicable) (3)
6 Calibration conditions(3)
6.1 Environmental conditions(3)
6.2 Measurement standards and other equipment (3)
7 Calibration items and calibration methods (4)
7.1 Appearance and functional inspection (4)
7.2 Short wavelength boundary deviation (4)
7.3 Transmitter window area deviation (4)
7.4 Relative error of energy density indication (4)
7.5 Repeatability(5)
7.6 Reproducibility (5)
7.7 Uniformity (6)
7.8 Relative error of pulse width indication (6)
7.9 Relative error of pulse interval indication (7)
7.10 Relative error of pulse repetition time indication (7)
8 Expression of calibration results (8)
9 Recalibration interval (8)
Appendix A Intense Pulsed Light Therapy Device Calibration Original Record (Recommended) Format (9)
Appendix B Calibration Certificate Inner Page (Recommended) Format (11)
Appendix C Example of evaluation of measurement uncertainty of relative error of energy density indication (14)
Appendix D Example of uncertainty evaluation of short wavelength boundary deviation measurement (18)
Appendix E Example of pulse width relative error measurement uncertainty evaluation (20)
Introduction
JJF 1071 "Rules for the Preparation of National Metrology and Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and
JJF 1059.1 "Evaluation and Expression of Uncertainty in Measurement" together constitute the basic series supporting the formulation of this specification
specification.
This specification refers to JJG312-1983 "Laser Energy Meter Calibration Procedure", JJG581-2016 "Medical Laser
Source Verification Procedure", JJF 1150-2006 "Photoelectric Detector Relative Spectral Response Calibration Specification", GB/T 2893.2-
2020 "Graphic Symbols, Safety Colors and Safety Signs Part 2.Design Principles for Product Safety Labels"
GB/T 30117.3-2019 Photobiological safety of lamps and lamp systems Part 3.Design of intense pulsed light sources for human body
Guidelines for the safe use of medical electrical equipment, YY9706.257-2021 Medical electrical equipment Part 2-57.Treatment, diagnosis and treatment
Particular requirements for the basic safety and essential performance of non-laser light source equipment used for diagnosis, monitoring and plastic surgery/medical beauty"
Technical standards and specifications.
This specification is published for the first time.
Intense pulsed light therapy device calibration specification
1 Scope
This specification applies to the calibration of high-intensity pulsed light therapy devices with incoherent output wavelengths of 400nm~1200nm.
2 References
This specification references the following documents.
JJG312-1983 Laser energy meter calibration procedures
JJG581-2016 Verification procedures for medical laser sources
JJF 1150-2006 Photoelectric detector relative spectral response calibration specification
GB/T 2893.2-2020 Graphical symbols, safety colors and safety signs Part 2.Product safety labels
Design principles
GB/T 30117.3-2019 Photobiological safety of lamps and lamp systems Part 3.Intense pulsed light to the human body
Guidelines for safe use of source equipment
YY9706.257-2021 Medical electrical equipment Part 2-57.Therapeutic, diagnostic, monitoring and plastic surgery/medical
Particular requirements for the basic safety and essential performance of non-laser light source equipment used in medical and aesthetic treatments
For any referenced document with a date, only the version with the date is applicable to this specification; for any referenced document without a date,
The latest version (including all amendments) shall apply to this specification.
3 Terms and definitions
The following terms and definitions defined in YY9706.257-2021 and GB/T 30117.3-2019 apply to this
specification.
3.1 Optical radiation
Electromagnetic radiation with a wavelength range of 100nm~1mm.
[Source. YY9706.257-2021,.201.3.211]
3.2 Intense pulsed light, IPL
Contains one or more incoherent lights with wavelengths ranging from 400nm to 1200nm, which can produce non-visual light in the human body.
It has the characteristics of wide spectrum range and high energy density and is used for treatment, plastic surgery or medical cosmetology.
Note. The pulse length is tens of milliseconds or shorter, and the pulse repetition frequency is usually 2Hz or lower. Strong pulse output is generally no greater than
50J/cm2.
[Source. YY9706.257-2021,.201.3.208; GB/T 30117.3-2019, 3.3, modified]
The wavelength at the short-wavelength edge of the emission spectrum where the intensity of the spectral line is 50%, measured in nanometers (nm).
[Source. YY9706.257-2021,.201.3.219]
3.4 Emission aperture
A hole or window through which optical radiation is emitted.
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of JJF 2153-2024_English be delivered?
Answer: Upon your order, we will start to translate JJF 2153-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of JJF 2153-2024_English with my colleagues?
Answer: Yes. The purchased PDF of JJF 2153-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.