JJF 1899-2021: Evaluation Methods for Field Strength in Electromagnetic Reverberation Chambers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1899-2021English329 Add to Cart 3 days [Need to translate] Evaluation Methods for Field Strength in Electromagnetic Reverberation Chambers Valid JJF 1899-2021

PDF similar to JJF 1899-2021


Standard similar to JJF 1899-2021

JJF 1234   JJF 1396   JJG 376   JJF 1894   JJF 1896   JJF 1893   

Basic data

Standard ID JJF 1899-2021 (JJF1899-2021)
Description (Translated English) Evaluation Methods for Field Strength in Electromagnetic Reverberation Chambers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A56
Word Count Estimation 14,178
Issuing agency(ies) State Administration for Market Regulation

JJF 1899-2021: Evaluation Methods for Field Strength in Electromagnetic Reverberation Chambers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Evaluation Methods for Field Strength in Electromagnetic Reverberation Chambers National Metrology Technical Specifications of the People's Republic of China Evaluation Method of Spatial Field Strength in Electromagnetic Reverberation Chamber Released on 2021-02-23 2021-08-23 implementation Issued by the State Administration for Market Regulation Evaluation Method of Spatial Field Strength in Electromagnetic Reverberation Chamber Focal point. National Radio Metrology Technical Committee Main drafting unit. China Institute of Metrology Tell Laboratory of China Academy of Information and Communications Technology Participated in the drafting. Hunan Institute of Metrology and Testing This specification entrusts the National Radio Measurement Technical Committee to be responsible for the interpretation The main drafters of this specification. Zhou Xin (China Institute of Metrology) Guo Xiaotao (China Institute of Metrology) Zhou Feng (Tail Laboratory of China Academy of Information and Communications Technology) Participating drafters. Liu Liangjiang (Hunan Institute of Metrology and Testing) Tian Fei (China Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 Reference documents (1) 3 Term (1) 3.1 Field uniformity (1) 3.2 Work space(1) 3.3 Inherent field uncertainty (1) 4 Overview (1) 5 Measurement characteristics (1) 6 Evaluation conditions (2) 6.1 Environmental conditions (2) 6.2 Measurement standards and other equipment (2) 7 Evaluation items and methods (3) 7.1 Workability (3) 7.2 Uniformity of field strength in reverberation room (3) 8 Evaluation result expression (5) Appendix A. Evaluation Record Reference Format (6) Appendix B Reference format of the inside page of the certificate (8)

Introduction

This specification is compiled in accordance with JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications". This specification refers to GB/T 17626.21 "Electromagnetic compatibility test and measurement technology mixing chamber test method" (IEC 61000-4-21) The definition of a reverberation room. This specification is released for the first time. Evaluation Method of Spatial Field Strength in Electromagnetic Reverberation Chamber

1 Scope

This specification stipulates that in the frequency range of.200MHz~18GHz, it is in accordance with GB/T 17626.21-2014 Evaluation of the spatial field strength characteristics of electromagnetic reverberation room (referred to as reverberation room, also called reverberation room) defined by [IEC 61000-4-21] Price method.

2 Reference documents

The following documents are cited in this specification. GB/T 17626.21 Electromagnetic compatibility test and measurement technology mixing chamber test method (IEC 61000-4-21) For dated reference documents, only the dated version applies to this specification; for undated reference documents, The latest version (including all amendments) is applicable to this specification.

3 Term

The following terms apply to this specification. 3.1 field uniformity fielduniformity A description of the uniformity of the electromagnetic field. 3.2 working space workingvolume The field uniformity of the electromagnetic field satisfies the space required by the index. 3.3 Intrinsic field uncertainty In the reverberation room, the randomness of the electromagnetic field contributes to the uncertainty of the field strength measurement. Note. A lot of reflections will occur when electromagnetic waves propagate in the reverberation room, which makes the electromagnetic field in the reverberation room have a strong randomness, which is obvious. This affects the accuracy of the field strength measurement in the reverberation room. In order to reduce this randomness, it will be repeated at different stirrer step positions Measure the field strength amplitude and take the average value as the result of the field strength measurement in the reverberation room. Measurement results of each agitator step position The standard deviation of is the inherent field standard uncertainty, which characterizes the degree of dispersion of the average value of the measurement results of each agitator step position.

4 overview

The reverberation chamber is a metal cavity whose inner wall is made of high-conductivity electromagnetic wave reflective material, which is usually equipped with Rotatable high-conductivity stirrer that can affect the electromagnetic environment in the room. Use the rotation of the stirrer in the reverberation room to change the reverberation room In the electromagnetic environment, when measured and averaged on enough stirrer step positions, the obtained field strength is statistically uniform. Uniform and isotropic. The reverberation chamber is mainly used for radiation emission test, immunity test of electronic equipment and cable, Shielding effectiveness test of connectors and chassis. Note. The number of rotations of the stirrer is the average number of field strength measurements, also known as the number of samples in the reverberation room.

5 Metrological characteristics

See Table 1 for the limit requirements of the field uniformity of the reverberation room.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1899-2021_English be delivered?

Answer: Upon your order, we will start to translate JJF 1899-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1899-2021_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1899-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.