HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1677-2017 English PDF

US$599.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1677-2017: Calibration Specification for Frequency Distribution Amplifiers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1677-2017English599 Add to Cart 5 days [Need to translate] Calibration Specification for Frequency Distribution Amplifiers Valid JJF 1677-2017

PDF similar to JJF 1677-2017


Standard similar to JJF 1677-2017

GB/T 3222.1   JJF 1234   JJF 1396   JJF 1900   JJF 1686   JJF 1680   

Basic data

Standard ID JJF 1677-2017 (JJF1677-2017)
Description (Translated English) Calibration Specification for Frequency Distribution Amplifiers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A57
Word Count Estimation 26,216
Date of Issue 2017-11-20
Date of Implementation 2018-02-20
Regulation (derived from) AQSIQ Notice 2017 No. 103
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 1677-2017: Calibration Specification for Frequency Distribution Amplifiers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Frequency Distribution Amplifiers People's Republic of China National Metrology Technical Specifications Frequency Distribution Amplifier Calibration Specifications Published on.2017-11-20 2018-02-20 Implementation The State Administration of Quality Supervision, Inspection and Quarantine issued Frequency Distribution Amplifier Calibration Specifications Key units. National Time Frequency Measurement Technical Committee Drafted by. China Academy of Metrology Participated in the drafting. Shijiazhuang Digital Equipment Co., Ltd. This specification entrusts the National Time Frequency Measurement Technical Committee to explain The main drafters of this specification. Xu Qinghua (China Institute of Metrology) Zhang Aimin (China Institute of Metrology) Participating drafters. Feng Wei (Shijiazhuang Digital Equipment Co., Ltd.) Zhang Yue (China Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 Terms and units of measurement (1) 3 Overview (1) 4 Metrological characteristics (1) 5 Calibration Conditions (2) 6 Calibration Items and Calibration Methods (3) 7 Expression of Calibration Results (7) 8 Re-school interval (8) Appendix A (9) Appendix B (13) Appendix C (16)

Introduction

This specification is based on JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", JJF 1001-2011 Using Measurement Terms and Definitions" and JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty. This specification is the first release. Frequency Distribution Amplifier Calibration Specifications

1 Scope

This specification applies to the calibration of frequency distribution amplifiers with a frequency range of (0.1 to 100) MHz.

2 Terms and units of measure

2.1 isolation isolation Leakage of radio frequency signals loaded into the output port of the frequency-sharing amplifier to power of other output ports or input ports The ratio of the input power to the loaded RF signal in dB. 2.2 Crosstalk crosstalk For multi-input multi-output frequency distribution amplifiers, when there is a signal input at a certain set of distribution amplification inputs In working condition, the output power of other distribution amplifiers with no input signal inactive is in operation The ratio of the output power of the distribution amplifier of the state, in dB.

3 Overview

Frequency distribution amplifier, also known as radio frequency distribution amplifier, is a signal from one channel (or multiplex) input, from multiple output And maintain the original signal characteristics of the instrument. The input multi-channel output frequency distribution amplifier principle is shown in Figure 1. enter The signal is converted into multiple outputs by the power divider and low noise amplifier. Frequency distribution amplifiers are widely used in communications, when Inter-frequency measurement and other fields. Figure 1 Frequency distribution amplifier block diagram

4 Metrological characteristics

4.1 Input and output frequency. Continuous frequency distribution amplifier is generally (0.1~100)MHz; fixed frequency allocation The amplifier is generally 5MHz, 10MHz, 100MHz and so on. 4.2 Gain (or output power). (-0.5~0.5)dB (For frequency distribution of the output power is fixed The output power is generally 13dBm).