US$419.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1658-2017: Calibration Specification for Loss-of-voltage Timers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1658-2017 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Loss-of-voltage Timers
| Valid |
JJF 1658-2017
|
PDF similar to JJF 1658-2017
Basic data Standard ID | JJF 1658-2017 (JJF1658-2017) | Description (Translated English) | Calibration Specification for Loss-of-voltage Timers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A57 | Classification of International Standard | 17.080 | Word Count Estimation | 18,168 | Date of Issue | 2017-11-20 | Date of Implementation | 2018-02-20 | Quoted Standard | JJF 1180; GB/T 17215.301-2007; DL/T 566-1995 | Regulation (derived from) | AQSIQ Notice 2017 No. 103 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the calibration of voltage-loss timers (pressure-loss timers, loss-of-voltage cut-off timers, loss-of-voltage cut-off short-circuit timers). |
JJF 1658-2017: Calibration Specification for Loss-of-voltage Timers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Voltage loss timer calibration standard)
People's Republic of China National Metrology Technical Specifications
Voltage loss timer calibration specification
Published on.2017-11-20
2018-02-20 Implementation
The State Administration of Quality Supervision, Inspection and Quarantine issued
Voltage loss timer calibration specification
Key units. National Time Frequency Measurement Technical Committee
The main drafting units. Zhengzhou Quality and Technology Supervision, Inspection and Test Center
Guizhou Provincial Measurement and Testing Institute
Participated in the drafting. Henan Power Company Zhengzhou Power Supply Company
Hubei Hongli Electronics Co., Ltd.
This specification entrusts the National Time Frequency Measurement Technical Committee to explain
The main drafters of this specification.
Ke Cunrong (Zhengzhou Quality and Technology Supervision, Inspection and Test Center)
Liu Xiaodong (Measuring Institute of Guizhou Province)
Participating drafters.
Zhang Xianghong (Zhengzhou Quality and Technology Supervision, Inspection and Test Center)
Su Baiyuan (Henan Provincial Power Company Zhengzhou Power Supply Company)
Feng Qingsong (Hubei Hongli Electronics Co., Ltd.)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 Terms and units of measure (1)
3.1 Starting voltage (1)
3.2 Return voltage (1)
3.3 Starting current (1)
3.4 Reference Voltage (1)
4 Overview (1)
5 Metrological characteristics (2)
5.1 Clock Differencing (2)
5.2 Starting voltage (2)
5.3 Return voltage (2)
5.4 Starting current (2)
6 Calibration Conditions (2)
6.1 Environmental Conditions (2)
6.2 Measurement Standards and Other Equipment (3)
7 Calibration Items and Calibration Methods (3)
7.1 Appearance and Function Check (3)
7.2 Clock Differential Calibration (3)
7.3 Starting Voltage and Return Voltage Measurement (5)
7.4 Starting Current Measurement (5)
7.5 Calibration Uncertainty for Evaluation of Clock Differencing, Starting Voltage and Starting Current (5)
8 Expression of Calibration Results (5)
9 Re-school interval (6)
Appendix A Calibration Record Format (7)
Appendix B Calibration Certificate Inner Page Format (8)
Appendix C Calibration Uncertainty Evaluation Example (9)
Introduction
This specification is based on JJF 1071-2010 "Rules for the preparation of national measurement calibration specifications", JJF 1001-2011
Using Measurement Terms and Definitions" and JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty.
This specification is the first release.
Voltage loss timer calibration specification
1 Scope
This specification applies to voltage-loss timers (pressure-loss timers, loss-of-voltage-off timers, loss-of-voltage-disconnected short-circuit timers
Calibration).
2 references
JJF 1180 Time Frequency Measurement Terminology and Definition
GB/T 17215.301-2007 Special requirements for multi-function electric energy meter
DL/T 566-1995 Voltage Voltage Loss Timer Specifications
For dated references, only dated editions apply to this specification; all undated references
The latest version (including all amendments) applies to this specification.
3 Terms and units of measure
3.1 Starting voltage triggervoltage
Let the timing unit act reliably and start counting the maximum input voltage in volts.
3.2 Return voltage returnvoltage
The minimum value of the input voltage to change the timing unit from timed to stopped. Unit. V.
3.3 Starting current trigger current
Under the condition that there is no voltage in the voltage loop, make the timing unit operate reliably and start the timing of the minimum input current
Value in mA.
3.4 Reference voltage referencevoltage
Determine the voltage value of the relevant characteristics of the meter, unit. V.
Classified according to different specifications, the reference voltage is generally divided into. 3 × 100V, 3 × 380V, 3 × 57.7/100V,
3×220/380V.
4 Overview
The voltage pressure loss timer (hereinafter referred to as the timer) is a dedicated device that displays and displays the voltage loop voltage loss time of the energy meter.
instrument. It is commonly used to monitor the operating status of three-phase three-wire (three-phase four-wire) active power (reactive power) meters. When running
The power meter under the condition of the load current, voltage transformer loss, undervoltage and current transformer secondary circuit open
When a road or man-made short circuit occurs, the timer can timely reflect the fault condition, give an alarm signal, and record the missing phase.
Pressure, breaking, short circuit time. According to the different functions, there are generally a pressure-loss timer, a pressure-loss timer, and a loss of voltage
Short-circuit timers and other types. Take three-phase three-wire as an example, the internal working principle of the timer is shown in Figure 1, outside the timer
The wiring is shown in Figure 2.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1658-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1658-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1658-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1658-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|