HOME   Cart(2)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1593-2016 English PDF

US$329.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1593-2016: Calibration Specification for Needle and Flake Gages
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1593-2016English329 Add to Cart 3 days [Need to translate] Calibration Specification for Needle and Flake Gages Valid JJF 1593-2016

PDF similar to JJF 1593-2016


Standard similar to JJF 1593-2016

JJF 1561   JJF 1406   JJF 1280   JJF 1960   JJF 1367   JJF 1583   

Basic data

Standard ID JJF 1593-2016 (JJF1593-2016)
Description (Translated English) Calibration Specification for Needle and Flake Gages
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Word Count Estimation 14,188
Date of Issue 2016-11-30
Date of Implementation 2017-02-28
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice No.119 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 1593-2016: Calibration Specification for Needle and Flake Gages

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Needle and Flake Gages National Metrological Technical Code of the People's Republic of China Standard Specification for Needle - like, Sheet - like Calibrator Calibration 2016-11-30 release 2017-02-28 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Standard Specification for Needle - like, Sheet - like Calibrator Calibration FlakeGag es Coordinate Unit. National Geometric Engineering Parameter Measurement Technical Committee The main drafting unit. Gansu Institute of Metrology Tianjin Institute of Metrology and Supervision Chengdu Metrology and Testing Institute Measurement and Testing Institute of Heilongjiang Province Participated in the drafting unit. Hebei Institute of Metrology The specification commissioned by the National Geometric Engineering Engineering Metrology Technical Committee is responsible for the interpretation The main drafters of this specification. Gao Yuhai (Gansu Institute of Metrology) Lu Ruijun (Tianjin Metrology Supervision and Research Institute of Science and Technology) Liu Jin (Chengdu Metrology and Testing Institute) Zhang weiwei (Heilongjiang province measurement test test institute) Participate in the drafters. Wang Shaoping (Hebei Institute of Metrology) Zhao Hongdong (Gansu Institute of Metrology) Chen Xiaodong (Gansu Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Metrological characteristics (2) 4.1 needle gauge gauge height (2) 4.2 needle-like gauge adjacent standard column spacing (2) 4.3 Flatness of the upper surface of the tablet gauge (2) 4.4 Length and width of the gauge gauge (2) 5 Calibration conditions (3) 5.1 Environmental conditions (3) 5.2 Calibration items and measuring standards and other equipment (3) 6 Calibration method (3) 6.1 needle gauge gauge column height (3) 6.2 needle gauge gauge adjacent standard column spacing (3) 6.3 Flatness of the upper surface of the tablet gauge (3) 6.4 Specification and length of gauge plate (4) 7 Calibration results (4) 8 Recurrence time interval (4) APPENDIX A Evaluation of Uncertainty in the Measurement of Adjacent Pitch Spacing of Needle-like Calibrator (5) APPENDIX B EVALUATION OF UNCERTAINTY FOR MEASURING HORIZONTAL WIDTH MEASUREMENTS (7) Appendix C Calibration Certificate Contents and Inside Page Format (9)

Introduction

This specification is a metrological specification for needle gauge and sheet gauge calibration. The development of this specification JJF 1071-2010 "Rules for the Preparation of National Metrological Calibration Standards", JJF 1001-2011 "General Metrological Terms and Definitions "JJF 1059.1-2012" measurement uncertainty assessment and representation "as the basic series of regulations. This specification is the first release. Standard Specification for Needle - like, Sheet - like Calibrator Calibration

1 Scope

This specification applies to the cement concrete aggregate and the construction of pebbles, gravel needle and flake particle classification screening needle Calibration of the gauge and sheet gauge.

2 reference file

This specification refers to the following documents. GB/T 6003.1-2012 Technical specifications and tests for test sieves - Part 1. Test screen for wire braid GB/T 14685-2011 Construction of pebbles, gravel Standard for quality and test methods for sand, stone for ordinary concrete JGJ52-2006 JTGE42-2005 test rules for highway engineering aggregate (T0311-2005 coarse aggregate for cement concrete) Needle-like particle content test) For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all amendments) applies to this specification.

3 Overview

Needle-like, sheet-like gauge is the cement concrete aggregate and construction of pebbles, gravel in the 4.75mm ~ 37.5mm Between the needle and the granular particles for grading screening of measuring instruments, it is widely used in construction engineering laboratory measurement needle And the size of the flaky particles. The needle gauge consists of a substrate and seven cylindrical columns, along the longitudinal axis of the substrate, two adjacent The distance between the columns and the bus bars is the spacing between adjacent columns. The shape of the needle gauge is shown in Fig. The sheet gauge is composed of a bracket and a standard plate, and there are six different specifications of the standard hole evenly distributed on the specification plate, Specified hole shape consists of three parts. the middle part of the rectangular, rectangular width is the standard hole width; both ends Divided into the diameter of the middle of the circular rectangle; along the longitudinal axis of the standard hole, the maximum distance between the two arcs is Standard hole length. The outline structure of the sheet gauge is shown in Fig. Figure 1 needle gauge gauge outline structure diagram 1 on-board surface; 2-gauge column; 3-adjacent string spacing; 4-gauge column height

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1593-2016_English be delivered?

Answer: Upon your order, we will start to translate JJF 1593-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1593-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1593-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.