HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1584-2016 English PDF

US$509.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1584-2016: Calibration Specification for Current Transformer Volt--Ampere Characteristic Meters
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1584-2016English509 Add to Cart 4 days [Need to translate] Calibration Specification for Current Transformer Volt--Ampere Characteristic Meters Valid JJF 1584-2016

PDF similar to JJF 1584-2016


Standard similar to JJF 1584-2016

JJF 1234   JJF 1576   JJG 376   JJF 2001   JJF 2000   JJF 1587   

Basic data

Standard ID JJF 1584-2016 (JJF1584-2016)
Description (Translated English) Calibration Specification for Current Transformer Volt--Ampere Characteristic Meters
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Word Count Estimation 22,274
Date of Issue 2016-11-25
Date of Implementation 2017-02-25
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice No.116 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 1584-2016: Calibration Specification for Current Transformer Volt--Ampere Characteristic Meters


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Current Transformer Volt - Ampere Characteristic Meters National Metrological Technical Code of the People's Republic of China Calibration specification for volt - ampere characteristic tester of current transformer 2016-11-25 release 2017-02-25 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Current transformer volt - ampere characteristics Tester calibration specification Unit. National Electromagnetic Metrology Technical Committee High Pressure Metering Subcommittee Major drafting unit. National high voltage metering station Participated in the drafting unit. State Grid Zhejiang Electric Power Company Electric Power Research Institute State Grid Shandong Electric Power Company Electric Power Research Institute Yunnan Electric Power Research Institute State Grid Hubei Electric Power Company Electric Power Research Institute State Grid Shanxi Electric Power Company Electric Power Research Institute This specification is commissioned by the National Electromagnetic Metrology Technical Committee of the High Pressure Metrology Subcommittee. The main drafters of this specification. Chapter Han (National High Voltage Meters Station) Xu Zili (National High Voltage Metering Station) Participate in the drafters. Xu Lingjie (State Grid Zhejiang Electric Power Company Electric Power Research Institute) Zhu Zhenhua (State Grid Shandong Electric Power Company Electric Power Research Institute) Liang Shibin (Yunnan Electric Power Research Institute) Ruan Ling (State Grid Hubei Electric Power Company Electric Power Research Institute) Zhao Yuan (State Grid Shanxi Electric Power Company Electric Power Research Institute)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Terminology (1) 3.1 Volt characteristic tester (1) 3.2 Excitation current (1) 3.3 Rated inflection point potential (1) 3.4 Excitation characteristics (1) 3.5 volt-ampere characteristics reference standard (1) 4 Overview (1) 5 Metrological characteristics (2) 5.1 Voltage (2) 5.2 Current (2) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Standard equipment for calibration (3) 7 Calibration items and calibration methods (4) 7.1 Calibration items (4) 7.2 Calibration method (4) 8 Calibration results (6) 9 re-school time interval (7) Appendix A Current Transformer Volt-ampere Characteristics Tester Measurement Uncertainty Evaluation Example (8) Appendix B Calibrate Original Record Format (12) Appendix C Calibration Certificate Inside Page Format (13) Appendix D Interpolation Algorithm Calculation Voltammetric Characteristics Standard Value (15) Appendix E Measurement characteristics of voltammetric reference standard (16)

Introduction

This specification is based on JJF 1071-2010 "national measurement calibration standard preparation rules" preparation. This specification is the first release. Calibration specification for volt - ampere characteristic tester of current transformer

1 Scope

This specification applies to the current transformer volt-ampere characteristic tester calibration, also applies to the current transformer with volt Sexual function of the test instrument calibration.

2 reference file

This specification refers to the following documents. Current Transformer for Measuring JJG313-2010 Transformers - Part 2. Supplementary technical requirements for current transformers GB/T Guide for test of transformers - Part 1. Current transformers GB/T For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 terminology

3.1 Volt-Amperecharacteristmeter Test equipment with volt-ampere characteristic measurement function of current transformer. 3.2 excitation current excitationcurrent Current transformer primary winding and other winding open circuit, the rated frequency of the sine wave voltage applied to the secondary terminal Through the current value of the secondary winding. Note. The steady-state protection current transformer excitation current is expressed by the root mean value; transient protection current transformer current excitation Using a peak representation. 3.3 rated inflection potential ratedkneepointe.mf When all the other terminals of the transformer are open, the rated frequency of the sine wave applied to the secondary terminal The root value of the field is increased by no more than 50% when the value is increased by 10%. Note. The actual inflection point potential is not less than the rated inflection point potential. 3.4 excitation characteristics When the current transformer primary winding and other windings open, applied to the current transformer secondary winding terminal The relationship between the square root value and the excitation current is expressed by a graph or a table. Note. These values are covered by a range sufficient to determine the excitation characteristics from the low excitation value up to 1.1 times the inflection point potential. 3.5 volt-ampere characteristics reference standard V-Icharacteristicstandardcurrenttransformer Volt characteristic The standard current transformer used in the calibration of the tester, whose excitation characteristic curve is calibrated and the performance stable.

4 Overview

Volt-ampere characteristic is a current transformer secondary winding sine wave voltage and excitation current value of the characteristic curve, commonly used

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1584-2016_English be delivered?

Answer: Upon your order, we will start to translate JJF 1584-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1584-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1584-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.