JJF 1559-2016: Calibration Specification of Variable Frequency Electric Quantity Analyzer
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1559-2016English529 Add to Cart 4 days [Need to translate] Calibration Specification of Variable Frequency Electric Quantity Analyzer Valid JJF 1559-2016

PDF similar to JJF 1559-2016


Standard similar to JJF 1559-2016

JJF 1234   JJF 1576   JJG 376   JJF 2001   JJF 2000   JJF 1558   

Basic data

Standard ID JJF 1559-2016 (JJF1559-2016)
Description (Translated English) Calibration Specification of Variable Frequency Electric Quantity Analyzer
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Word Count Estimation 23,281
Date of Issue 2016-03-03
Date of Implementation 2016-06-03
Quoted Standard JJG 780-1992; GB/T 13978-2008
Regulation (derived from) Announcement No.26 of the General Administration of Quality Supervision, Inspection and Quarantine
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJF 1559-2016: Calibration Specification of Variable Frequency Electric Quantity Analyzer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification of Variable Frequency Electric Quantity Analyzer National Metrological Technical Code of the People's Republic of China Code for calibration of variable frequency power analyzers 2016-03-03 release 2016-06-03 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Code for calibration of variable frequency power analyzers Unit. National Electromagnetic Metrology Technical Committee The main drafting unit. Hunan Institute of Measurement and Testing Zhejiang Institute of Metrology Participated in the drafting unit. Hunan Galaxy Electric Co., Ltd. This specification entrusts the National Electromagnetic Metrology Technical Committee to explain. The main drafters of this specification. Wu Shuanghe (Hunan Institute of Measurement and Testing) Wang Yougui (Hunan Institute of Measurement and Testing) Liu Qin (Zhejiang Institute of Metrology) Participate in the drafters. Li Yixuan (Hunan Institute of Measurement and Testing) Wang Ning (Hunan Galaxy Electric Co., Ltd.) Xu Wei (Hunan Galaxy Electric Co., Ltd.)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Metering characteristics (1) 4.1 Voltage (1) 4.2 Current (1) 4.3 Phase (1) 4.4 Power (2) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Measurement standards and other equipment (2) 6 Calibration items and calibration methods (2) 6.1 Check before calibration (2) 6.2 Voltage (2) 6.3 Current (4) 6.4 Phase (6) 6.5 Power (8) 7 Calibration results (11) 8 re-school time interval (11) Appendix A Example of uncertainty assessment of power measurement results for variable frequency power analyzers (12) Appendix B Calibrate Original Record Format (14) Appendix C Calibration Certificate Inside Page Format (Page 2) (16) Appendix D Calibration Certificate Calibration Result Page Format (Page 3) (17)

Introduction

This specification is based on the national measurement technical specifications JJF 1071-2010 "national measurement calibration standard preparation rules" JJF 1001-2011 "General Metrology Terms and Definitions" and JJF 1059.1-2012 "Measurement Uncertainty Assessment and Table Show "the preparation. This specification is the first release. Code for calibration of variable frequency power analyzers

1 Scope

This specification applies to the frequency range of 5Hz ~ 1500Hz frequency conversion power analyzer at a specific frequency voltage, Current, power, phase calibration.

2 reference file

This specification refers to the following documents. AC Digital Power Meter JJG780-1992 Digital Multimeter. GB/T 13978-2008 For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 Overview

Frequency conversion power analyzer is composed of sampling circuit, control unit, transmission unit and digital processor composed of variable frequency The flow signal is the instrument for the measurement and analysis. The analyzer adopts the sampling circuit to adopt the measured voltage and current signal Sample, RMS calculation and Fourier analysis, showing the measured signal voltage, current, power factor (phase), power And other parameters, the principle shown in Figure 1. Variable frequency power analyzer (hereinafter referred to as analyzer) usually includes power analysis Instrument, voltage/current analyzer and so on. Figure 1 Schematic diagram of the analyzer

4 measurement characteristics

4.1 Voltage Measuring range. 50mV ~ 10kV Maximum permissible error. ± (0.05% ~ 2%) 4.2 Current Measuring range. 10mA ~ 1000A Maximum permissible error. ± (0.05% ~ 2%) 4.3 phase Measuring range. 0 ° ~ 360 ° Maximum permissible error. ± (0.01 ° ~ 0.5 °)

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1559-2016_English be delivered?

Answer: Upon your order, we will start to translate JJF 1559-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1559-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1559-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.