US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1545-2015: Calibration Specification for Testers for Measuring Raceway Diameter and Angle of Tapered Roller Bearing Ring Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1545-2015 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Testers for Measuring Raceway Diameter and Angle of Tapered Roller Bearing Ring
| Valid |
JJF 1545-2015
|
PDF similar to JJF 1545-2015
Basic data Standard ID | JJF 1545-2015 (JJF1545-2015) | Description (Translated English) | Calibration Specification for Testers for Measuring Raceway Diameter and Angle of Tapered Roller Bearing Ring | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A52 | Classification of International Standard | 17.040 | Word Count Estimation | 15,172 | Date of Issue | 2015-08-24 | Date of Implementation | 2016-02-24 | Older Standard (superseded by this standard) | JJG 886-1995 | Quoted Standard | JJG 39; JJG 118 | Regulation (derived from) | AQSIQ Announcement 2015 No.106 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard is applicable to the calibration of tapered roller bearing ring raceway diameters and angle gauges with index values ??of 0.5��m and 1��m and upper measuring range up to 500mm. |
JJF 1545-2015: Calibration Specification for Testers for Measuring Raceway Diameter and Angle of Tapered Roller Bearing Ring ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Testers for Measuring Raceway Diameter and Angle of Tapered Roller Bearing Ring
People's Republic of China National Metrology Technical Specifications
Tapered roller bearing ring raceway diameter,
Angle measuring instrument calibration specification
Issued on. 2015-08-24
2016-02-24 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Tapered roller bearing ring raceway diameter,
Angle measuring instrument calibration specification
Instead of JJG886-1995
NFP. National Engineering Geometrical Parameters Measurement Technology Committee
The main drafting units. Shandong Institute of Metrology
Hebei Academy of Supervision and Testing
Participated in the drafting unit. Yantai Bearing Instrument Co., Ltd.
Luoyang LYC Bearing Co., Ltd.
Xiamen verification test hospital
This specification project commissioned by the National geometric parameter measurement technology committee responsible for the interpretation
The main drafters of this specification.
Liu Dazhong (Shandong Province Institute of Metrology)
Zhao Dongsheng (Shandong Province Institute of Metrology)
Wang Shaoping (Hebei Supervision and Testing Institute)
Yu Zhi Shan (Shandong Province Institute of Metrology)
Drafters participate.
Xu Qi (Yantai Bearing Instrument Co., Ltd.)
Pang Huaqi (Luoyang LYC Bearing Co., Ltd.)
Deng water, fat (Xiamen verification test hospital)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 Metrological characteristics (2)
4.1 Surface roughness (2)
4.2 Transmission lever flatness anvil surface (2)
Face flatness table 4.3 (2)
Height difference 4.4 three face orientation fulcrum (2)
4.5 Indication Error indicator (2)
4.6 load and load change (2)
4.7 Indication variability (2)
4.8 Indication error (2)
Calibration Condition 5 (2)
5.1 environmental conditions (2)
5.2 standards and measuring equipment (3)
6 calibration items and calibration methods (3)
6.1 calibration items (3)
6.2 Calibration method (3)
7 Calibration result expression (5)
8 Recalibration interval (5)
Appendix A raceway diameter, measurement angle measuring instrument Indication Error Uncertainty Evaluation (6)
Appendix B calibration certificate within the page and format (9)
Introduction
JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common terminology and measurement
Definitions ", JJF 1130-2005" geometric measurement equipment calibration Uncertainty Evaluation Guide ", JJF 1094-
2002 "Evaluation of measuring instrument characteristics", together constitute the support of the calibration norm-setting series of basic norms.
The specification for the revision, instead of JJG886-1995 "tapered roller bearing ring raceway diameter, angle measuring instrument."
Compared with JJG886-1995, in addition to editorial changes, the major technical changes are as follows.
--- Based JJG63-2007 "knife-shaped ruler" to cancel the 0 and level 1 requirements.
--- Based JJG118-2010 "torsion spring comparator" method of verification, the original value of the change in procedures shown in "test
Times the amount of no less than 10 times "to" five times the number of measurements. "
--- Indication of the change of uniform requirements to 0.5μm.
--- Shows the calibration value of the standard error of the device to pairing diameter gauge.
--- Increased in the calibration certificate format page content.
The previous versions of this specification published case.
JJG886-1995.
Tapered roller bearing ring raceway diameter,
Angle measuring instrument calibration specification
1 Scope
This instruction applies to indexing is 0.5μm and 1μm, the upper limit of the measuring range to 500mm tapered roller bearings
Ring raceway diameter, angle measuring instrument calibration.
2. References
This specification refers to the following documents.
JJG39 mechanical comparator
JJG118 torsion spring comparator
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Tapered roller bearing ring raceway diameter, angle measuring instrument (hereinafter referred to as raceway diameter, angle measuring instrument) is
Comparative Measurement tapered roller bearings inside (or outside) ring raceway diameter, raceway inclination of the reference line element end face of instrument
Device. Common instrument structure shown in Figure 1 and Figure 2.
1 inner ring raceway diameter, angle measuring instrument
1- table; 2- fixed fulcrum; 3 - face orientation fulcrum;
4- inner ring; 5- diameter probe; 6- indicator;
7- transmission lever; 8- angle probe; 9- measuring force adjusting handwheel
Figure 2 the outer ring raceway diameter, angle measuring instrument
1- table; 2 - face orientation fulcrum; 3- handling wrench;
4- outer ring; 5- indicator; 6- angle probe;
7- diameter probe; 8- measuring force adjusting handwheel
|