JJF 1532-2015: Calibration Specification for Baseband Fading Simulators
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1532-2015English809 Add to Cart 5 days [Need to translate] Calibration Specification for Baseband Fading Simulators Valid JJF 1532-2015

PDF similar to JJF 1532-2015


Standard similar to JJF 1532-2015

JJF 1234   JJF 1396   JJG 376   JJF 2016   JJF 1534   JJF 1533   

Basic data

Standard ID JJF 1532-2015 (JJF1532-2015)
Description (Translated English) Calibration Specification for Baseband Fading Simulators
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A56
Classification of International Standard 17.220
Word Count Estimation 35,365
Date of Issue 2015-06-15
Date of Implementation 2015-09-15
Quoted Standard JJF 1286-2011
Regulation (derived from) AQSIQ Announcement 2015 No.72
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to newly manufactured, the use of the simulator calibration and repair after baseband fading.

JJF 1532-2015: Calibration Specification for Baseband Fading Simulators

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Baseband Fading Simulator calibration specification) People's Republic of China National Metrology Technical Specifications Baseband Fading Simulator Calibration Specification Issued on. 2015-06-15 2015-09-15 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Baseband Fading Simulator Calibration Specification BasebandFading Simulators Focal point. the National Radio Technical Commission metering Drafted by. the Ministry of Industry and Information Technology and Telecommunication Metrology Center This specification commissioned the National Radio Technical Commission responsible for the interpretation of measurement The main drafters of this specification. Guo Khanh (Ministry of Industry and Information Technology Telecommunication Metrology Center) Sun Jinglu (Industry and Information Technology Ministry of Communications Measurement Center) Drafters participate. Ran Zhiqiang (Ministry of Industry and Information Technology Telecommunication Metrology Center)

table of Contents

Introduction (Ⅲ) 1 Scope (1) 2. References (1) 3 Overview (1) 4 Metrological characteristics (1) 4.1 Reference crystal oscillator (1) Path loss 4.2 (1) 4.3 Doppler shift (1) 4.4 Frequency Response (1) 4.5 DC bias voltage (1) 4.6 spectral purity (1) 4.7 path delay (2) 4.8 I/Q imbalance (2) 4.9 voltage input and output ports (2) Calibration Condition 5 (2) 5.1 environmental conditions (2) 5.2 Calibration Equipment (2) 6 calibration items and calibration methods (3) 6.1 appearance and working properly check (3) 6.2 Reference crystal oscillator frequency accuracy (3) Path loss 6.3 (4) Doppler shift 6.4 (4) 6.5 Frequency Response (4) 6.6 DC bias voltage (5) Spectral purity 6.7 (5) 6.8 path delay (6) 6.9 I/Q imbalance (6) 6.10 path-through channel function tests (7) 6.11 Fading simulation function tests (7) 7 Calibration Results The expression (8) 8 Recalibration interval (9) Appendix A Calibration Record Form (10) Appendix B Calibration Certificate-page format (14) Evaluation of Uncertainty Appendix C Examples (17) Appendix D schematic of a typical wireless fading theoretical model (29)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment. This specification method for the calibration of the baseband fading simulator, respectively from the reference frequency accuracy of the crystal oscillator path Loss, Doppler shift, the frequency response, the DC bias voltage, spectral purity, path delay, I/Q imbalance, the letter Road path through, aspect function tests were prescribed, and gives a measurement calibration project in the appendix of Uncertainty Evaluation examples. This specification is the first release. Baseband Fading Simulator Calibration Specification

1 Scope

This standard applies to newly manufactured, use the simulator calibration and repair after baseband fading. 2. References This specification references the following documents. JJF 1286-2011 radio channel simulator calibration specification Note. For dated references, only the dated edition applies to this specification; undated reference documents, the most The new version (including any amendments) applies to this specification.

3 Overview

Baseband Fading Simulator input signal sampling, the use of digital signal processing algorithms for digital sampling sequence Treatment and then the digital sequence processed through digital to analog conversion, filtering and other aspects of the output can be fully parametric solid ground Setup signal propagation environment simulation model to simulate Doppler shift, Rayleigh fading, fading signal propagation Special Rice Zheng, with GSM, CDMA, WLAN and other wireless communication standards analog channel capacity, mainly for wireless communication Research and development equipment and product development, manufacturing and evaluation.

4 Metrological characteristics

4.1 Reference crystal oscillator Frequency. 10MHz Accuracy. 1 × 10-6 4.2 path loss Path loss range. 0dB ~ 50dB The maximum permissible error. ± 0.3dB 4.3 Doppler shift Doppler shift range. 0.1Hz ~ 1600Hz The maximum permissible error. ± 1% 4.4 Frequency Response Frequency range. 5Hz ~ 160MHz Frequency response. -0.6dB ~ 0.1dB 4.5 DC bias voltage DC voltage range. -2V ~ 2V The maximum permissible error. ± 2mV 4.6 spectral purity. < - 60dBc

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1532-2015_English be delivered?

Answer: Upon your order, we will start to translate JJF 1532-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1532-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1532-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.