HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1480-2014 English PDF

US$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1480-2014: Calibration Specification for Liquid-scintillation Counting System
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1480-2014English349 Add to Cart 3 days [Need to translate] Calibration Specification for Liquid-scintillation Counting System Valid JJF 1480-2014

PDF similar to JJF 1480-2014


Standard similar to JJF 1480-2014

GB/T 3222.1   JJG 188   JJF 1396   JJF 1474   JJF 1479   JJF 1473   

Basic data

Standard ID JJF 1480-2014 (JJF1480-2014)
Description (Translated English) Calibration Specification for Liquid-scintillation Counting System
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 15,187
Date of Issue 8/25/2014
Date of Implementation 11/25/2014
Quoted Standard JJF 1001-2011; GB/T 4960.1-2010; GB/T 4960.3-2008; GB/T 10259-2013; IEC 61304-1994
Regulation (derived from) People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 (No. 95); AQSIQ Notice 2014 No. 95
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard applies to radionuclide activity measurement range Bq liquid scintillation counter (analyzer) calibration [0 to 10 (5)].

JJF 1480-2014: Calibration Specification for Liquid-scintillation Counting System

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Liquid-scintillation Counting System People's Republic of China National Metrology Technical Specifications Liquid scintillation counter calibrated specifications CountingSystem Issued on. 2014-08-25 2014-11-25 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Liquid scintillation counter calibrated specifications Focal point. the National Technical Committee of ionizing radiation metrology Drafting. Shanghai Institute of Measurement and Testing China Institute of Metrology This specification commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this specification. He Linfeng (Shanghai Institute of Measurement and Testing) Tangfang Dong (Shanghai Institute of Measurement and Testing) Liang Jun Cheng (China Institute of Metrology) Drafters participate. Liu Haoran (China Institute of Metrology) Xu Yihe (Shanghai Institute of Measurement and Testing)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (2) 4 Overview (2) 5 Metrological characteristics (2) Energy range 5.1 (2) 5.2 activity measurement range (2) 5.3 background count rate (2) 5.4 detection efficiency (2) 5.5 Repeatability (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 Measurement Standards (2) 7 calibration items and calibration methods (3) 7.1 background count rate (3) 7.2 No quenching standard source detection efficiency (3) 7.3 Repeatability (3) 7.4 quenching efficiency calibration curve (4) 8 calibration results expression (4) 9 Recalibration interval (4) Appendix A liquid scintillation counter calibrated recording format recommended (5) Appendix B liquid scintillation counter within the calibration certificate pages (6) Appendix C liquid scintillation counter detection efficiency calibration 3H Uncertainty Evaluation Example (7)

Introduction

The main basis for this specification in accordance with JJF 1071-2010 "National Calibration Specifications writing rules" written preparation Of GB/T 10259-2013 "liquid scintillation counter," and refer to the International Electrotechnical Commission standard IEC 61304.1994 "Nuclear Instrument Performance Verification liquid scintillation counter" (Nuclearinstrumentation- Liquid-scintilationcountingsystems-Performanceverification) and the American National Standards AN- SIN42.15.1990 "liquid scintillation counting system performance test" (Performanceverificationofliquid- 1986 sealed radioactive "for liquid scintillation counter. scintilationcountingsystem), ANSIN42.16 Check supply specifications "(SpecificationsforSealedRadioactiveCheckSourcesUsedinLiquid- ScintilationCounters). As radionuclide activity measurement instruments used in a liquid scintillation counter more β-ray emitting nuclide, in particular Low energy β-ray measurements of radionuclide 3H and 14C activity in. This specification defines a liquid scintillation counter calibrated measuring 3H and 14C Radionuclide detection efficiency calibration method is also applicable to other radionuclide detection efficiency calibration. The specification for the first time to develop. Liquid scintillation counter calibrated specifications

1 Scope

This instruction applies to radionuclide activity measurement range (0 ~ 105) Bq liquid scintillation counter (Analysis Meter) calibration. 2. References This specification references the following documents. JJF 1001-2011 common measurement terms and definitions GB/T 4960.1-2010 nuclear science and technology terms - Part 1. Nuclear Physics and Chemistry GB/T 4960.6-2008 nuclear science and technology - Part 6. Nuclear instrumentation GB/T 10259-2013 liquid scintillation counter IEC 61304.1994 Nuclear Instrument Performance Verification liquid scintillation counter (Nuclear instrumentation-Liquid-scintilationcountingsystems-Performanceverification) Above dated references, only the dated edition applies to this specification.

3 terminology and units of measurement

3.1 Terms JJF 1001-2011, GB/T 4960.1-2010, GB/T 4960.6-2008 defined and the following terms and Definitions apply to this specification. 3.1.1 The background count rate backgroundcountrate Instrument unit time count measurement floor samples. 3.1.2 detection efficiency detectionefficiency Instrument count rate divided by the standard source of activity. 3.1.3 Liquid Scintillation standard source liquidscintilationreferencesource The activity of certain radionuclides known scintillation liquid miscible with the sealed glass vial of standard size, for determining Given liquid scintillation counter detection efficiency of standard sources. 3.1.4 Flashing substance scintilatingmaterial Ionizing radiation, capable of flashing light-emitting substance radiation. 3.1.5 quencher quenchingagent Can reduce the emission intensity of the phosphor material. 3.1.6 quenching standard source quenchedstandardsource Factors reducing the light output with standard source. 3.1.7 No quenched standard source unquenchedstandardsource With a small (negligible) impact standard light source output factors.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1480-2014_English be delivered?

Answer: Upon your order, we will start to translate JJF 1480-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1480-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1480-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.