HOME   Cart(6)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1352-2012 English PDF

US$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1352-2012: Calibration Specification for Angular-Position Transducers/Sensors
Status: Valid

JJF 1352: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1352-2012English439 Add to Cart 4 days [Need to translate] Calibration Specification for Angular-Position Transducers/Sensors Valid JJF 1352-2012
JJF 1352-1990English239 Add to Cart 2 days [Need to translate] O.T.N. of Radioactivity Primary Standard for Tritium Gas and Tritiated Water Obsolete JJF 1352-1990

PDF similar to JJF 1352-2012


Standard similar to JJF 1352-2012

JJF 1561   JJF 1406   JJF 1280   JJF 1347   JJF 1349   JJF 1345   

Basic data

Standard ID JJF 1352-2012 (JJF1352-2012)
Description (Translated English) Calibration Specification for Angular-Position Transducers/Sensors
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 19,149
Quoted Standard GB/T 18459-2001; JB/T 9256-1999; JB/T 9257-1999; JB/T 9258-1999
Regulation (derived from) AQSIQ Announcement No. 96 of 2012
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to inductive angular displacement sensor, differential transformer angular displacement sensor (DC input type, AC input type), resistive angular displacement sensor, capacitive angular displacement sensor calibration static performan

JJF 1352-2012: Calibration Specification for Angular-Position Transducers/Sensors

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Angular-Position Transducers/Sensors People's Republic of China National Metrology Technical Specifications Angular displacement sensor calibration specification Issued on. 2012-06-18 2012-09-18 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Angular displacement sensor calibration specification Angular-PositionTransducers / Sensors Focal point. the National Technical Committee of length measuring geometry Main drafting unit. Shaanxi Provincial Institute of Metrology Chinese Flight Test Establishment Participated in the drafting. AVIC Xi'an Flight Automatic Control Research Institute State-owned China Aviation Industry East Instrument Factory This specification length measuring geometry commissioned the National Technical Committee is responsible for interpretation The main drafters of this specification. Liu Ying (Shaanxi Provincial Institute of Metrology) Qin Yu (Shaanxi Provincial Institute of Metrology) Wu Yonghong (Chinese Flight Test Establishment) Drafters participate. Mao Cui (Chinese Flight Test Establishment) Liu Yuan degree (AVIC Xi'an Flight Automatic Control Research Institute) Han Juntao (AVIC state-owned East Instrument Factory)

table of Contents

Introduction (Ⅲ) 1 Scope (1) 2. References (1) 3 Terms and definitions (1) Phase shift 3.1 (1) 3.2 Reference null position (1) 3.3 Zero-voltage (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 Sensitivity (1) 5.2 Linearity (1) 5.3 Return error (1) 5.4 Repeatability (2) 5.5 ripple voltage (2) 5.6 Zero-voltage (2) 5.7 phase shift (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) Major equipment 6.2 calibration (2) 7 calibration items and calibration methods (3) 7.1 Clamping the wiring (3) 7.2 Reference null position (3) 7.3 determine the calibration point (3) 7.4 Data Acquisition (3) 7.5 sensitivity and intercept (3) 7.6 Linearity (4) 7.7 Return error (5) 7.8 Repeatability (5) 7.9 ripple voltage (5) 7.10 zero voltage (5) 7.11 phase shift (5) 8 calibration results expression (5) 9 Recalibration interval (6) A differential transformer calibration AC angular displacement sensor angle error appendix (7) Appendix B AC differential transformer angular displacement sensor linearity measurements Uncertainty Evaluation (8) Appendix C calibration certificate contents (12)

Introduction

In the present specification JJF 1071-2010 "National Calibration Specifications writing rules", GB/T 18459-2001 "sensor The main static performance index calculation method "to prepare the basis for the main. This specification is the first release. Angular displacement sensor calibration specification

1 Scope

This instruction applies to inductive angular displacement sensor, differential transformer-type angular displacement sensor (DC input type, cross Stream input type), resistive angular displacement sensor, a capacitive angular displacement sensor calibrated static performance indicators. 2. References This specification refers to the following documents. GB/T 18459-2001 sensor is mainly static performance index calculation method JB/T 9256-1999 inductive displacement sensor JB/T 9257-1999 AC differential transformer displacement sensor JB/T 9258-1999 DC differential transformer displacement sensor For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms and definitions

3.1 phase shift phaseshift Maximum stroke at the linear operating range of angular displacement sensor output voltage to the input voltage fundamental in fundamental Retardation time. 3.2 Reference Electrical zero electricalnul Angular displacement of the rotor position sensor output voltage meets the voltage corresponding to the equation, the equation is zero electrical angle θ Set is a reference null position. Angular displacement sensor in this position the output voltage to a minimum. 3.3 Zero Voltage nulvoltage Rotor angular displacement sensor in a reference null position when the output voltage is the minimum value of the output voltage.

4 Overview

Is an angular displacement sensor can feel the amount of angular displacement of the measuring instrument and converted into a usable output signal. Their work Principle can be divided into resistive angular displacement sensor, a capacitive angular displacement sensor, inductive angular displacement sensor, differential transformer Is angular displacement sensor (DC input type, AC input type) and the like. The principles of various angular displacement sensor shown in Figure 1.

5 Metrological characteristics

5.1 sensitivity 5.2 Linearity 5.3 Return Error

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1352-2012_English be delivered?

Answer: Upon your order, we will start to translate JJF 1352-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1352-2012_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1352-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1352-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1352-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.