US$309.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1224-2009: Calibration Specification for Reinforced Concrete Covermeter and Floorslab Thickness Tester Status: Valid JJF 1224: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1224-2009 | English | 309 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Reinforced Concrete Covermeter and Floorslab Thickness Tester
| Valid |
JJF 1224-2009
|
JJF 1224-1990 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
O.T.N.for Pressure Primary Standard in the Range from 0 to 2500Pa
| Obsolete |
JJF 1224-1990
|
PDF similar to JJF 1224-2009
Basic data Standard ID | JJF 1224-2009 (JJF1224-2009) | Description (Translated English) | Calibration Specification for Reinforced Concrete Covermeter and Floorslab Thickness Tester | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A52 | Classification of International Standard | 17.040 | Word Count Estimation | 13,177 | Date of Issue | 2009-07-10 | Date of Implementation | 2009-10-10 | Quoted Standard | JJF 1001-1998; JJF 1059-1999; JJF 1094-2002; GB 50204-2002 | Regulation (derived from) | AQSIQ Announcement No. 78 of 2009 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to reinforced protective layer thickness measuring instrument and the slab thickness measuring instrument calibration. |
JJF 1224-2009: Calibration Specification for Reinforced Concrete Covermeter and Floorslab Thickness Tester ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Reinforced Concrete Covermeter and Floorslab Thickness Tester
People's Republic of China National Metrology Technical Specifications
Reinforced protective layer, floor thickness
Measuring instrument calibration specification
Posted 2009-07-10
2009-10-10 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Reinforced protective layer, floor thickness
Measuring instrument calibration specification
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 10, 2009, and from
From October 10, 2009 into effect.
NFP. National Engineering Geometrical Parameters Measurement Technology Committee
The main drafting units. China Institute of Metrology
Beijing Institute of Metrology detection
Guangdong Provincial Institute of Metrology
Shanghai Measurement and Testing Technology Research Institute
Zhibo the Beijing Science and Technology Co., Ltd.
Participated in the drafting unit. China Testing Technology Research Institute
Hilti (China) Co., Ltd.
This specification by the responsible National Engineering Geometrical Parameters Technical Commission explained
The main drafters of this specification.
Zhang Heng (China Institute of Metrology)
Wu Xun (Beijing Institute of Metrology detection)
Zhang Yong (Guangdong Institute of Metrology)
Liu Yin (Shanghai Institute of Measurement and Testing)
Pipe Jun (Beijing Zhibo Technology Co., Ltd.)
Drafters participate.
Ran Qing (China Testing Technology Research Institute)
Wang Conghui (Hilti (China) Co., Ltd.)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 measurement repeatability (1)
5.2 indication error (1)
6 calibration conditions (3)
Environmental conditions 6.1 (3)
6.2 Calibration with a standard block (3)
7 calibration items and calibration methods (3)
7.1 Measurement repeatability (3)
7.2 Indication Error (4)
8 calibration results expression (4)
8.1 calibration certificate (4)
8.2 calibration measurement uncertainty (4)
9 Recalibration interval (4)
Appendix A reinforced protective layer thickness measuring instrument error of measurement results are shown Uncertainty Evaluation (5)
Appendix B Technical requirements standard blocks (7)
Appendix C calibration certificate contents (8)
Reinforced protective layer, floor thickness gauge calibration specification
1 Scope
This standard applies to the thickness of the slab thickness gauges and gauge calibration reinforced protective layer.
2 Citations
This specification references the following documents.
JJF 1001-1998 common measurement terms and definitions
JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement
JJF 1094-2002 measuring instrument characteristics evaluation
Construction quality concrete structures GB 50204-2002 acceptance
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Terms
Reinforced protective layer thickness (thicknessoftheconcreteprotectivecoating). refers to the outer edge of the steel surface
To its distance from the surface of the protective layer.
4 Overview
Reinforced protective layer, floor thickness gauge refers reinforced protective layer thickness measuring instrument and slab thickness gauge. they
It is the principle of electromagnetic nondestructive testing instrument for building structures and physical protection layer thickness slab thickness
measuring.
Reinforced protective layer thickness gauge probes (having a transmitter and receiver functions) transmits electromagnetic signals, the protection layer steel
Tendons secondary induced magnetic field, the probe is received by the instrument to give reinforced protective layer thickness or bar diameter
Measurements. Instrument can also be used to measure the distribution of steel.
Slab thickness gauge transmitter and receiver probes were placed on the surface and the bottom surface of the floor test, launch probe launch
Electromagnetic signals received by the receiving probe magnetic field attenuated signal, after processing equipment to obtain thickness measurements of the floor.
Schematic diagram of the instrument shown in Figure 1, respectively, as shown in Figure 2.
5 Metrological characteristics
5.1 Measurement repeatability
Reinforced protective layer thickness measuring instrument measurement repeatability requirements of Table 1, the slab thickness gauge measurement repeatability asked to see
Table 2.
5.2 Indication error
5.2.1 reinforced protective layer thickness measuring instrument
Reinforced protective layer thickness measuring instrument shows the measured value of the maximum permissible error according to the thickness of the protective layer of reinforced division, asked to see
Table 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1224-2009_English be delivered?Answer: Upon your order, we will start to translate JJF 1224-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1224-2009_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1224-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1224-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1224-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|