JJF 1191-2019: Calibration Specification for Acoustic Performance of Audiometry Rooms
Status: Valid

JJF 1191: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1191-2019English549 Add to Cart 5 days [Need to translate] Calibration Specification for Acoustic Performance of Audiometry Rooms Valid JJF 1191-2019
JJF 1191-2008English919 Add to Cart 4 days [Need to translate] Calibration Specification for Acoustic Performance of Audiometry Rooms Obsolete JJF 1191-2008

PDF similar to JJF 1191-2019


Standard similar to JJF 1191-2019

GB/T 3222.2   GB/T 3222.1   JJG 188   JJG 1190   JJG 1191   JJG 1182   

Basic data

Standard ID JJF 1191-2019 (JJF1191-2019)
Description (Translated English) Calibration Specification for Acoustic Performance of Audiometry Rooms
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A59
Classification of International Standard 17.140
Word Count Estimation 25,260
Date of Issue 2019
Date of Implementation 2020-03-27
Issuing agency(ies) State Administration for Market Regulation

JJF 1191-2019: Calibration Specification for Acoustic Performance of Audiometry Rooms

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration specification for acoustic characteristics of audiometry rooms) National Measurement Technical Specification of the People's Republic of China Calibration specification for acoustic characteristics of audiometry rooms 2019-09-27 release 2020-03-27 Implementation Issued by the State Administration of Market Supervision and Administration Calibration specification for acoustic characteristics of audiometry rooms Replace JJF 1191-2008 Centralized unit. National Acoustic Metrology Technical Committee Main drafting unit. Shanghai Institute of Metrology and Testing Technology Chinese Academy of Metrology Participated in the drafting unit. Fujian Institute of Metrology Guangzhou Institute of Metrology and Testing Technology Jiangsu Academy of Metrology This specification is entrusted to the National Acoustic Metrology Technical Committee for interpretation The main drafters of this specification. An Zhaoliang (Shanghai Institute of Metrology and Testing Technology) Zhong Bo (Chinese Academy of Metrology) Participating drafters. Zhou Ziwei (Shanghai Institute of Metrology and Testing Technology) Li Qun (Fujian Institute of Metrology) Zhou Changhua (Guangzhou Institute of Metrology and Testing Technology) Yun Wu (Jiangsu Institute of Metrology) Deng Zheng (Shanghai Institute of Metrology and Testing Technology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terms and units of measurement (1) 4 Overview (2) 5 Metrological characteristics (2) 5.1 Noise floor sound pressure level (2) 5.2 Sound field characteristics (6) 5.3 Airborne sound insulation characteristics (6) 6 Calibration conditions (6) 6.1 Environmental conditions (6) 6.2 Measurement standards and other equipment (6) 7 Calibration items and calibration methods (7) 7.1 Calibration items (7) 7.2 Check before calibration (7) 7.3 Sound pressure level calibration method for noise floor (7) 7.4 Calibration method of sound field characteristics (8) 7.5 Calibration method of airborne sound insulation characteristics (10) 8 Expression of calibration results (11) 8.1 Calibration data processing (11) 8.2 Calibration certificate (11) 8.3 Uncertainty evaluation of calibration results (11) 9 Recalibration time interval (11) Appendix A Contents of Calibration Certificate in Audiometry Room (12) Appendix B Examples of uncertainty assessment of calibration results (17)

Introduction

This specification is written in accordance with the requirements and format of JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications". In terms of technology, we mainly refer to GB/T 16296.2-2016 "Acoustic Audiometry Methods Part 2.Using Pure Sound field audiometry of sound and narrowband test signals", ISO 8253-1.2010 "Acoustic Hearing Test Methods Part 1. "Pure-tone air conduction and bone conduction audiometry" requirements and test methods for the performance parameters of "background noise sound pressure level" and "sound field characteristics" Method, refer to GB/T 19885-2005 "Laboratory and on-site measurement of sound insulation performance of acoustic insulation rooms" The test method for "airborne sound insulation characteristics" is specified. This regulation replaces JJF 1191-2008 "Specification for Calibration of Acoustic Characteristics of Audiometry Room". Phase with JJF 1191-2008 The main technical changes are as follows. --- Added the measurement content of air acoustic insulation characteristics. The previous releases of this specification are. ---JJF 1191-2008. Calibration specification for acoustic characteristics of audiometry rooms

1 Scope

This specification applies to the frequency range from 125Hz to 12.5kHz, using air-conducting headphones, speakers or bone vibrators as Sound-generating device; use pure tones, FM tones, narrow-band noise, or recorded language materials as audiometry signals for hearing threshold checks The determination and evaluation of the acoustic characteristics of the listening room. The airborne sound insulation measurement specified in this specification is applicable to the listening room and external air Measurement of sound insulation performance. This specification is also applicable to the measurement of acoustic characteristics of the audiometry room for measuring otoacoustic emissions and auditory evoked potentials.

2 Reference documents

This specification refers to the following documents. JJG176-2005 Sound Calibrator JJG449-2014 octave and fractional octave filters JJF 1034-2005 Acoustic measurement terms and definitions JJF 1059.1-2012 Evaluation and expression of measurement uncertainty GB/T 3102.7-1993 Acoustic quantities and units GB/T 16296.2-2016 Acoustic audiometry method Part 2.Sound using pure tone and narrow band test signal Field audiometry GB/T 19885-2005 Laboratory and field measurement of sound insulation performance of acoustic insulation room GB/T 20441.4-2006 Measurement microphones Part 4.Specifications of working standard microphones GB 50118-2010 Code for sound insulation design of civil buildings GB/T 50121-2005 Evaluation standard for sound insulation of buildings ISO 8253-1.2010 Acoustic Hearing Test Method Part 1.Pure Tone Air Conduction and Bone Conduction Audiometry (Acoustics-Audiometrictestmethods-Part 1.Pure-toneairandboneconductionaudi- ometry) For dated reference documents, only the dated version applies to this specification; for those without date references The latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

This specification adopts the quantity and unit specified in GB/T 3102.7. The terms and definitions defined in JJF 1034-2005 and the following apply to this specification. 3.1 reference point When the subject is located in the test position of the sound field, the two ear canal openings of the subject are connected to the midpoint of the straight line. 3.2 reference axis The axis perpendicular to the radiating surface of the speaker. For single radiators or horn speakers, the shaft passes through the diaphragm or horn Geometric center.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1191-2019_English be delivered?

Answer: Upon your order, we will start to translate JJF 1191-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1191-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1191-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1191-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1191-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.