US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1189-2008: Calibration Specification for Length Measuring Instrument Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1189-2008 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Length Measuring Instrument
| Valid |
JJF 1189-2008
|
PDF similar to JJF 1189-2008
Basic data Standard ID | JJF 1189-2008 (JJF1189-2008) | Description (Translated English) | Calibration Specification for Length Measuring Instrument | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A52 | Classification of International Standard | 17.040 | Word Count Estimation | 14,189 | Date of Issue | 2008-03-24 | Date of Implementation | 2008-06-24 | Older Standard (superseded by this standard) | JJG 55-1984 | Quoted Standard | JJF 1001; JJF 1059; JJF 1094 | Regulation (derived from) | AQSIQ Announcement No. 35 of 2008 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard specifies the communication tunable laser source (hereinafter referred to as a tunable source) common metrological characteristics, calibration methods and equipment used in the calibration requirements, etc., for the first time tunable source calibration, calibration and use in subsequent tests. Other similar tunable source calibration can be implemented by reference. Tunable source type evaluation requirements relating to metrological characteristics, can refer to this specification. |
JJF 1189-2008: Calibration Specification for Length Measuring Instrument---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Length Measuring Instrument
People's Republic of China National Metrology Technical Specifications
Length measuring instrument calibration specification
Posted 2008-03-24
2008-06-24 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Length measuring instrument calibration specification
LengthMeasuring
Instrument
Instead of JJG55-1984
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on March 24, 2008, and from
From June 24, 2008 into effect.
Focal point. the National Technical Committee of length measuring geometry
Main drafting unit. Jiangsu Province Institute of Metrology
China Institute of Metrology
This specification length measuring geometry commissioned the National Technical Committee is responsible for interpretation
The main drafters of this specification.
ROADS (Jiangsu Province Institute of Metrology)
Goal Orientation (Jiangsu Province Institute of Metrology)
Wang farming (China Institute of Metrology)
Drafters participate.
Hu Qing (Guiyang Xintian Optoelectronics Technology Co., Ltd.)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Overview (1)
4 Metrological characteristics (1)
4.1 flat cap and measured flatness vertical length measuring instrument fixed table (1)
4.2 Indication variability (1)
4.3 indication error (1)
4.4 measurement repeatability (1)
4.5 measured dimension indication error (1)
5 calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Main standard equipment and ancillary equipment (1)
Calibration Method 6 (2)
6.1 measurement plane caps, fixed table flatness (2)
6.2 Indication variability (3)
6.3 Indication error (3)
6.4 Measurement repeatability (4)
6.5 measured dimension indication error (4)
7 Calibration Results (4)
8 Recalibration interval (5)
Appendix A Evaluation of Uncertainty in Measurement (Example) (6)
Appendix B Typical length measuring instrument main technical parameters (8)
Appendix C shows the range of values > is 1100mm auxiliary calibration method (9)
Length measuring instrument calibration specification
1 Scope
This standard applies to the length measuring instrument calibration.
2 Citations
This specification references the following documents.
JJF 1001-1998 common measurement terms and definitions
JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement
JJF 1094-2002 measuring instrument characteristics evaluation
When using this specification the calibration should be noted that using the currently valid version of the documents cited.
3 Overview
Length measuring instrument is an optical mechanical or electromechanical combination of length measuring instruments, structure is divided into horizontal and vertical length measuring instrument
Type length measuring instrument.
Length measuring instrument by the base, seat and measuring measuring axis, tailstock, table, length of the standard device (scale or grating) and
Readings or display device component. Length measuring instrument used to cover the entire range, continuous scale length of the standard device.
Length measuring instrument measured by direct measurement or comparison of the measured gauge block, measuring tools, smooth gauge, thread gauge and fine
Parts of machinery and length dimensions.
4 Metrological characteristics
4.1 Flatness measurement plane caps and vertical length measuring instrument fixed table
4.2 Indication variability
4.2.1 Indication variability measured using a flat cap when
4.2.2 Indication variability measurement using a spherical cap when
4.3 Indication error
4.4 Measurement repeatability
4.5 measured dimension indication error
5 calibration conditions
5.1 Environmental conditions
Ambient temperature is generally controlled within (20 ± 3) ℃, or in accordance with the technical requirements of the relevant provisions.
5.2 Main standard equipment and ancillary equipment (see Table 1)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1189-2008_English be delivered?Answer: Upon your order, we will start to translate JJF 1189-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1189-2008_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1189-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|