Standard ID JJF 1154-2006 (JJF1154-2006)
Description (Translated English) Calibration Specification for Four-wheel alignmenter
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 17,132
Date of Issue 2006/5/23
Date of Implementation 2006-08-23
Quoted Standard JJF 1001-1998, JJF 1059-1999, JJF 1094-2002, GB/T 3730.3-1992
Drafting Organization Liaoning Province metering Scientific Academy
Administrative Organization Geometrical parameters of the National Engineering Measurement Technology Committee
Regulation (derived from) ?AQSIQ Announcement 2014 No.125
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to optical, electronic and mechanical wheel alignment calibration.

JJF 1154-2006
Calibration Specification for Four-wheel alignmenter
National Metrology Technical Specification of the People's Republic
Four wheel aligner calibration specification
Released on.2006-05-23
Implementation of.2006-08-23
The General Administration of Quality Supervision, Inspection and Quarantine issued
Four wheel aligner calibration specification
Four-wheelalig
This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on May 23,.2006, and
Implemented on August 23,.2006.
Focal Point. National Geometric Quantity Engineering Measurement Technology Committee
Main drafting unit. Liaoning Institute of Metrology
China Testing Technology Research Institute
Participated in the drafting unit. Qingdao Metrology and Testing Institute
Heilongjiang Institute of Metrology
This specification is interpreted by the National Geometric Quantity Engineering Measurement Technology Committee.
The main drafters of this specification.
Zhang Yaoyuan (Liaoning Institute of Metrology)
Liu Meisheng (China Testing Technology Research Institute)
Participate in the drafters.
Miao Chunfa (Qingdao Metrology and Testing Institute)
Wang Jie (Heilongjiang Institute of Metrology)
Sun Da (Liaoning Institute of Metrology)
Deng Ping (Liaoning Institute of Metrology)
Che Xuan (Liaoning Institute of Metrology)
Shan Yujun (Liaoning Institute of Metrology)
table of Contents
1 range (1)
2 Citations (1)
3 Terms and definitions (1)
3.1 Four wheel aligner (1)
3.2 single wheel toe angle (1)
3.3 Wheel camber (1)
3.4 caster angle (1)
4 Overview (1)
5 Measurement characteristics (2)
5.1 The plane formed by the clamp jaws and the perpendicularity of the mounting head shaft (2)
5.2 Zero value drift (2)
5.3 indication error (2)
6 Calibration conditions (3)
6.1 Environmental conditions (3)
6.2 Standard Equipment for Calibration (3)
7 Calibration items and calibration methods (3)
7.1 Calibration Project (3)
7.2 Calibration method (3)
7.3 Single wheel toe angle indication error (4)
7.4 Wheel camber angle indication error (4)
7.5 Leading pin inclination angle indication error (5)
8 Expression of calibration results (5)
9 re-interval time interval (5)
Appendix A Measurement Performance and Calibration Method of Turntable (6)
Appendix B Evaluation of Uncertainty of Measurement Errors of Four Wheel Aligners (7)
Appendix C Four Wheel Alignment Calibration Record (9)
Appendix D Calibration Certificate or Calibration Report Content (11)
Four wheel aligner calibration specification
1 Scope
This specification applies to the calibration of optical, electronic and mechanical four-wheel aligners.
2 Citations
This specification refers to the following documents.
JJF 1001-1998 General measurement terms and definitions
JJF 1059-1999 Measurement Uncertainty Evaluation and Representation
JJF 1094-2002 Technical Specifications for Measuring Instrument Characteristics
GB/T 3730.3-1992 Terms for vehicles and trailers and their definition of vehicle dimensions
Use of this specification should be done with the current valid version of the above cited documents.
3 Terms and definitions
3.1 Four wheel aligner (four-wheelalignmenter)
An instrument for measuring the four wheel alignment parameters of a car.
3.2 single wheel toe angle (individualwheeltoe-in)
The inner angle of the rotation plane of each wheel with respect to the longitudinal axis of the vehicle (geometric centerline) is called the single wheel toe angle.
(θ), the front end of the wheel is positive toward the longitudinal axis, and vice versa.
3.3 wheel camber (camber)
The angle between the center plane of the wheel and the vertical plane of the car. When the top of the wheel is tilted toward the outside of the car, the angle is positive.
It is negative.
3.4 caster angle (camberbiff)
The line connecting the tip of the ball or the top of the strut to the lower ball and the plumb line on the suspension, and the angle viewed from the side of the car. on