JJF 1078-2002: Calibration Specificaiton for Optical Comparators for Angle Measurement
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1078-2002English549 Add to Cart 4 days [Need to translate] Calibration Specificaiton for Optical Comparators for Angle Measurement Valid JJF 1078-2002

PDF similar to JJF 1078-2002


Standard similar to JJF 1078-2002

JJG 1114   JJF 1280   JJF 1126   JJG 1088   JJF 1088   JJG 1078   

Basic data

Standard ID JJF 1078-2002 (JJF1078-2002)
Description (Translated English) Calibration Specificaiton for Optical Comparators for Angle Measurement
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Word Count Estimation 21,221
Date of Issue 2002-04-15
Date of Implementation 2002-07-01
Older Standard (superseded by this standard) JJG 203-1980
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to optical angle measuring instrument calibration comparison.

JJF 1078-2002: Calibration Specificaiton for Optical Comparators for Angle Measurement

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specificaiton for Optical Comparators for Angle Measurement National Metrology Technical Specification of the People's Republic Optical Angle Measuring Comparator Calibration Specification Released on.2002-04-15 2002-07-01 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Replace JJG203-1980 This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on April 15,.2002, and Implemented on July 1,.2002. Focal Point. National Geometric Angle Measurement Technical Committee Drafting unit. Hunan Institute of Metrology and Testing Technology This specification is interpreted by the focal point The main drafters of this specification. Xiao Xiaoping (Hunan Institute of Metrology and Testing Technology) Bao Wei (Hunan Institute of Metrology and Testing Technology)

table of Contents

1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Measurement characteristics (1) 4.1 Appearance (1) 4.2 Instrument optical axis and table perpendicularity (2) 4.3 Micrometer backhaul difference (2) 4.4 The micro-drum engraved line is consistent with the ruler line (2) 4.5 Deviation of the indication value of the micrometer reading (2) 4.6 Workbench flatness (2) 4.7 indication error (2) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Standards and other equipment for calibration (2) 6 Calibration items and calibration methods (2) 6.1 Appearance (2) 6.2 Verticality of instrument optical axis and table (2) 6.3 Micrometer backhaul (2) 6.4 Compliance between the micro-drum engraved line and the ruler engraved line (2) 6.5 Deviation of the indication value of the micrometer reading (2) 6.6 Flatness of the workbench (3) 6.7 indication error (3) 7 Expression of calibration results (4) 8 re-study interval (4) Appendix A Calculation Example (5) Appendix B Optical Angle Measuring Comparator Indication Error Measurement Uncertainty Evaluation (7) Appendix C Calibration Certificate (inside page) format and content (16) Optical Angle Measuring Comparator Calibration Specification

1 Scope

This specification applies to the calibration of optical goniometers.

2 Citations

This specification refers to the following documents. JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation JB/T 6266-1992 Basic parameters of optical angle measuring comparator Use of this specification should be done with the current valid version of the above cited documents.

3 Overview

The optical goniometer can measure the angle of metal and optical parts by comparison with standard or angle blocks. Direct measurement at small angles also measures the linearity of the guide rails, the parallelism and verticality of the components. The optical angle measuring comparator can be divided into two types. no micrometer and micrometer. 1-Workbench 2 - Vertical Arm 3 - Self-collimating light tube 4 - Eyepiece

4 Measurement characteristics

4.1 Appearance The new optical angle measuring comparator shall have the manufacturer's name or trademark, model number, factory number and logo.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1078-2002_English be delivered?

Answer: Upon your order, we will start to translate JJF 1078-2002_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1078-2002_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1078-2002_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.