HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JG/T 390-2012 English PDF

US$629.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JG/T 390-2012: Chiller and heat pump unit with condensing heat recovery for air conditioning system
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JG/T 390-2012English629 Add to Cart 5 days [Need to translate] Chiller and heat pump unit with condensing heat recovery for air conditioning system Valid JG/T 390-2012

PDF similar to JG/T 390-2012


Standard similar to JG/T 390-2012

GB/T 13554   JG/T 402   JG/T 286   JGJ/T 390   JG/T 292   

Basic data

Standard ID JG/T 390-2012 (JG/T390-2012)
Description (Translated English) Chiller and heat pump unit with condensing heat recovery for air conditioning system
Sector / Industry Building & Construction Industry Standard (Recommended)
Classification of Chinese Standard Q76
Classification of International Standard 91.140.30
Word Count Estimation 24,251
Quoted Standard GB/T 4272; GB/T 4706.32; GB/T 7725-2004; GB/T 8174; GB/T 10870-2001; GB/T 13306; GB/T 13384; GB/T 17758-2010; GB/T 18430.1 -2007; GB/T 18430.2-2008; GB/T 21362-2008; JB/T 4330; JB/T 7666; JB 8654; JB 8655
Regulation (derived from) Ministry of Housing and Urban Notice No. 1468; industry standard filing Notice 2013 No. 1 (No. 157 overall)
Issuing agency(ies) Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary This standard specifies the air conditioning condensation heat recovery equipment, terms and definitions, classification and marking, requirements, test methods, inspection rules, marking, packing and storage. This standard applies to industrial and civil

JG/T 390-2012: Chiller and heat pump unit with condensing heat recovery for air conditioning system


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chiller and heat pump unit with condensing heat recovery for air conditioning system ICS 91.140.30 Q76 People's Republic of China building industry standards Air conditioning condensing heat recovery equipment Posted on.2012-09-21 2012-12-01 implementation Ministry of Housing and Urban-Rural Development, People's Republic of China released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 classification and marking 3 5 basic provisions 3 6 Requirements 5 7 Test Method 6 8 Inspection rules 9 9 logo, packaging and storage 10 Appendix A (Informative) Air-conditioning system of condensation heat recovery equipment 12 Appendix B (Normative) Condensate heat recovery and the determination of integrated energy efficiency coefficient and calculation method 14 Appendix C (Informative) Condensation heat recovery rate and the integrated energy efficiency coefficient measurement and calculation methods 18

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the Ministry of Housing and Urban Standard and Design Institute. This standard by the Ministry of Housing and Urban Construction Environment and Energy Standardization Technical Committee. This standard is drafted by. Hunan University. Participated in the drafting of this standard. Guangzhou Star Refrigeration Machinery Manufacturing Co., Ltd., Guangdong Tong Yi Electric Co., Ltd., China Building Research Institute, Trane Air Conditioning Systems (China) Co., Ltd., Nanjing University of Technology, Wuhan Institute of Architectural Design, Zhongkai College of Agricultural Engineering, Clement Czech Republic, refrigeration equipment (Shanghai) Co., Ltd. The main drafters of this standard. Gong Guangcai, Liu Zhandong, Tang Bi Kui, Cao Yang, Jia Jing, Gong Yanfeng, Chen Yanhua, Ding Lihang, Wang Fu Li, Zhang Ling, Su Huan, Zhang Quan. Air conditioning condensing heat recovery equipment

1 Scope

This standard specifies the terms and definitions of air conditioning condensing heat recovery equipment, classification and marking, requirements, test methods, inspection rules, signs, packages Loading and storage. This standard applies to industrial and civil buildings driven by the motor using vapor compression refrigeration cycle of cold water (heat pump) unit condensation Heat recovery equipment, also applies to room air conditioners and unitary air conditioners condensing heat recovery equipment. This standard does not apply to drinking water, beverages and water as a cold (heat) agents for industrial equipment.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 4272 equipment and pipe insulation technology GB 4706.32 Household and similar electrical appliances safety heat pump, air conditioning and dehumidifiers special requirements (GB 4706.32-2004, IEC 60335-2-40..1995, IDT) GB/T 7725-2004 room air conditioners GB/T 8174 Equipment and piping insulation effect of the test and evaluation Performance test methods for volumetric and centrifugal chilled water (heat pump) units GB/T 10870-2001 GB/T 13306 signs GB/T 13384 mechanical and electrical product packaging General technical conditions Unitary air conditioner GB/T 17758-2010 GB/T 18430.1-2007 Vapor compression cycle cold water (heat pump) unit - Part 1. Industrial or commercial and similar purposes Cold water (heat pump) unit GB/T 18430.2-2008 Steam compression circulating cold water (heat pump) unit - Part 2. Household and similar uses of cold water (heat Pump) unit Heat pump water heaters for commercial or industrial use and similar purposes GB/T 21362-2008 Refrigeration and air conditioning equipment JB/T 4330 Determination of noise JB/T 7666 refrigeration and air conditioning equipment nominal conditions of the general provisions JB8654 volumetric and centrifugal cold water (heat pump) unit safety requirements JB8655 unitary air conditioner safety requirements

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Condensing heat condensingheat Refrigeration (heat pump) The amount of heat released by the condensing side of the unit during cooling.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JG/T 390-2012_English be delivered?

Answer: Upon your order, we will start to translate JG/T 390-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JG/T 390-2012_English with my colleagues?

Answer: Yes. The purchased PDF of JG/T 390-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.