  Basic data             |  Standard ID  |          JG 305-2011 (JG305-2011) |               |  Description (Translated English)  |          Safety requirement for powered pedestrian doors |               |  Sector / Industry  |          Building & Construction Industry Standard |               |  Classification of Chinese Standard  |          A90 |               |  Classification of International Standard  |          13 |               |  Word Count Estimation  |          21,212 |               |  Date of Issue  |          2011-02-17 |               |  Date of Implementation  |          2011-08-01 |               |  Quoted Standard  |          GB/T 5823; GB 15763; GB 50009; JGJ 113; JG/T 177-2005 |               |  Regulation (derived from)  |          Bulletin of the Ministry of Housing and Urban-Rural Development, No. 921 |               |  Issuing agency(ies)  |          Ministry of Housing and Urban-Rural Development of the People's Republic of China |               |  Summary  |          This standard specifies the safety requirements for pedestrian automatic doors terms and definitions, requirements, test methods and inspection rules. This standard applies to civil buildings for people to access the sliding automatic doors, flat open automatic doors, automatic doors and rotating folding automatic doors.  |         
  JG 305-2011: Safety requirement for powered pedestrian doors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.  
Safety requirement for powered pedestrian doors
ICS 13
A90
People's Republic of China building industry standards
Pedestrian automatic door safety requirements
2011-02-17 released
2011-08-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Foreword â…¢
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Requirements 2
5 test methods 6
6 Inspection rules 10
Appendix A (Normative) Safety signs 12
Appendix B (Normative) The main danger area, the sub-dangerous area shows the scope of 13
Appendix C (normative) different types of automatic door instructions 15
Appendix D (Normative) Impact measurement location 16
Foreword
Chapter 4 of this standard is mandatory, the rest is recommended.
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Construction Building Products and Components Products Standardization Technical Committee.
This standard is drafted by. Beijing Bao Dundang Door Technology Co., Ltd.
Participated in the drafting of this standard. Naboke Automatic Door (Beijing) Co., Ltd., Beijing Kai will Sheng automatic doors Technology Co., Ltd., Doma Door
Control Technology (China) Co., Ltd., Ruida up to automatic doors (Shanghai) Co., Ltd., Matsushita Electric Works (China) Co., Ltd., Liaoning Shengwei Electrical and Mechanical Services
Technology Co., Ltd., the State Construction Engineering Quality Supervision and Inspection Center, Ningbo Ou Nike Automatic Door Co., Ltd., Dongguan Jian Long Hardware Products
Limited.
The main drafters of this standard. fee to red, Lin Zili, Zhang Lei, Ye Zenguang, Zhang Guoqing, Chen Mingyue, Wei Hao Wen, Tang Feng, Mao Hongwei, Liu Huitao,
Li Li, Wang Jie Tang, Wang Miao, Xu Wu manganese.
Pedestrian automatic door safety requirements
1 Scope
This standard specifies the terms and definitions, requirements, test methods and inspection rules for the safety requirements of pedestrian automatic doors.
This standard applies to civil buildings in the popular push-pull automatic doors, open the automatic doors, folding automatic doors and rotating automatic doors.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 5823 building doors and windows terminology
GB 15763 Building safety glass
GB 50009 Building structural load specifications
JG J113 architectural glass application of technical regulations
JG/T 177-2005 automatic doors
3 Terms and definitions
GB/T 5823, JG/T 177-2005 established and the following terms and definitions apply to this document.
3.1
Pedestrian automatic door powered pedestriandoor
Automatic doors for people to access.
3.2
Active fan frontmüller leadingmulion
For a straight fan running activities, is the last to close the activities of the import and export of vertical fan; for rotating fan activities, means
Away from the center of rotation at the forefront of the rung.
3.3
Sensor
A device or device that can sense the person or object under test and convert it to an available electrical signal according to a certain rule,
And conversion components; also known as sensors or sensors.
3.4
Presence sensor presencesensor
Detects the presence of a person or object in a given area.
3.5
Pressure-sensitive sensors pressure-sensitiveequipment
A sensor that receives a certain amount of pressure and generates a corresponding amount of compression and at the same time sends an electrical signal to the control system.
3.6
On the radio sensor photobeamsensor
One end of the beam to receive the light beam at the other end, while the control device to send electrical signals sensors.
   
   
  
  
    
  
    
   
        
       
          
               
 
          |