HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GBZ6113.3-2019 English PDF

US$4904.00 ยท In stock
Delivery: <= 11 days. True-PDF full-copy in English will be manually translated and delivered via email.
GBZ6113.3-2019: Specification for radio disturbance and immunity measuring apparatus and methods -- Part 3: CISPR technical reports
Status: Valid

GBZ6113.3: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/Z 6113.3-2019English4904 Add to Cart 11 days [Need to translate] Specification for radio disturbance and immunity measuring apparatus and methods -- Part 3: CISPR technical reports Valid GB/Z 6113.3-2019
GB/Z 6113.3-2006EnglishRFQ ASK 3 days [Need to translate] Specification for radio disturbance and immunity measuring apparatus and methods -- Part 3: CISPR technical report Obsolete GB/Z 6113.3-2006

PDF similar to GBZ6113.3-2019


Standard similar to GBZ6113.3-2019

GB/T 6113.103   GB/T 6113.104   GB/T 6113.102   GB/T 6113.106   GB/Z 6113.404   GB/T 6113.402   

Basic data

Standard ID GB/Z 6113.3-2019 (GB/Z6113.3-2019)
Description (Translated English) Specification for radio disturbance and immunity measuring apparatus and methods -- Part 3: CISPR technical reports
Sector / Industry National Standard
Classification of Chinese Standard L06
Classification of International Standard 33.100
Word Count Estimation 258,252
Date of Issue 2019-08-30
Date of Implementation 2020-03-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GBZ6113.3-2019: Specification for radio disturbance and immunity measuring apparatus and methods -- Part 3: CISPR technical reports


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
GB /Z 6113.3-2019 Specification for radio disturbance and immunity measuring apparatus and methods - Part 3. CISPR technical reports ICS 33.100 L06 National Standardization Technical Document of the People's Republic of China Replace GB /Z 6113.3-2006 Radio disturbance and immunity measuring equipment And measurement method specifications Part 3. Radio disturbance and immunity Measurement technology report methods-Part 3. CISPRtechnicalreports (CISPRTR16-3..2015, IDT) 2019-08-30 released 2020-03-01 implementation State market supervision and administration China National Standardization Administration issued

Content

Foreword I 1 Scope 1 2 Normative references 1 3 Terms, definitions and abbreviations 2 3.1 Terms and Definitions 2 3.2 Abbreviations 4 4 Technical Report 6 4.1 Correlation of measurements made with CISPR devices with measurements made using devices other than CISPR characteristics 6 4.2 Interference Simulator 12 4.3 Interrelationship between open test site limits and reverberation chamber limits 15 4.4 Long-wave (LW), medium-wave (MW) and short-wave (SW) band amplitude modulation (AM) broadcast transmitters are sensed in the telephone subscriber line Classification and characteristics of asymmetric disturbance sources 16 4.5 Predictability of radiation in the vertical direction above 30 MHz 33 4.6 Predictive radiation in the vertical direction below 30MHz 81 4.7 Correlation between amplitude probability distribution (APD) characteristics of harassment and performance of digital communication systems 148 4.8 Measuring Receiver RMS Value - Background Information Defined by Average Weighted Detector 166 4.9 Common Mode Absorption Device (CMAD) 189 4.10 Background information defined based on the FFT receiver 202 4.11 Signal parameters of the telecommunications port 219 4.12 Background information on CDNE equipment and measurement methods 220 5 Background and History 226 5.1 History of CISPR 226 5.2 Historical background. Measurement methods for interference power generated by household appliances and similar electrical appliances in the VHF range 229 Appendix A (informative) Formula derivation 231 Appendix B (informative) Field strength distribution 234 Appendix C (informative) Asymmetric Open Circuit Voltage Distribution 237 Appendix D (informative) Socket voltage distribution 240 Appendix E (informative) Some mathematical relations 242 Appendix F (informative) Harmonic field of different elevation angles of the 27MHz ISM device on the actual ground 244 References 250

Foreword

GB/T (Z) 6113 "Specifications for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods" is the basic standard for electromagnetic compatibility, and is composed of the following four major Part of the composition. Part 1. Radio disturbance and immunity measuring equipment --- Part 1-1. Radio disturbance and immunity measuring equipment measuring equipment; --- Part 1-2. Coupling devices for measurement of conducted disturbances in radio disturbance and immunity measuring devices; --- Part 1-3. Radio disturbance and immunity measuring equipment auxiliary equipment disturbance power; --- Part 1-4. Radio disturbance and immunity measuring equipment - Radiation disturbance measuring antennas and test sites; --- Part 1-5. Radio disturbance and immunity measuring equipment 5MHz~18GHz antenna calibration site and reference test site; ---Parts 1-6. EMC antenna calibration for radio disturbance and immunity measuring equipment. Part 2. Radio disturbance and immunity measurement methods --- Part 2-1. Radio disturbance and immunity measurement methods - Conductive disturbance measurement; --- Part 2-2. Radio disturbance and immunity measurement methods - Harassment power measurement; --- Part 2-3. Radio disturbance and immunity measurement method Radiative disturbance measurement; --- Part 2-4. Radio disturbance and immunity measurement methods - Immunity measurement; --- Part 2-5. Field measurement of large equipment harassment emissions. Part 3. Technical report on radio disturbance and immunity measurement --- Part 3. Technical report on radio disturbance and immunity measurement. Part 4. Uncertainty, statistics, and limit modeling --- Part 4-1. Uncertainty, statistical and limit modeling Modeling EMC test uncertainty; --- Part 4-2. Uncertainty, statistics and limits modeling uncertainty of equipment and facilities; --- Part 4-3. Uncertainty, statistics and limits modeling statistical considerations for the determination of EMC compliance for batch products; --- Part 4-4. Calculation models for statistical and limit values for uncertainty, statistics and limit modeling; --- Part 4-5. Uncertainty, statistics and limits modeling conditions for the use of alternative test methods. This part is the third part of GB/T (Z) 6113. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB /Z 6113.3-2006 "Radio disturbance and immunity measurement equipment and measurement methods - Part 3. Wireless Technical Report on Electrical Disturbance and Immunity Measurement, the main technical changes compared with GB /Z 6113.3-2006 are as follows. --- Added six terms such as "weighting (for example, weighting for impulse harassment)"; --- Increased the correlation between 4.7 "Amplitude Probability Distribution (APD) characteristics of harassment and the performance of digital communication systems"; --- Added 4.8 "Measurement Receiver RMS Value - Background Information Defined by Average Weighted Detector"; --- Added 4.9 "Common Mode Absorption Device (CMAD)"; --- Added 4.10 "background information based on FFT receiver definition"; --- Added 4.11 "Signal parameters of the telecom port"; --- Added 4.12 "Background information for CDNE devices and measurement methods". This section uses the translation method equivalent to CISPRTR16-3.2015 "Radio Disturbance and Immunity Measurement Equipment and Measurement Method Specification Part 3. CISPR Technical Report. The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows. ---GB 4824-2013 Industrial, Scientific and Medical (ISM) Radio Frequency Equipment Harassment Characteristics Limits and Measurement Methods (CISPR 11.2010, IDT) --- GB/T 6113.101-2016 Radio disturbance and immunity measuring equipment and measuring methods - Part 1-1. Radio Harassment and Immunity Measurement Equipment Measurement Equipment (CISPR16-1-1..2010, IDT) This section has made the following editorial changes. --- For the sake of understanding, the definition of "slipback peak" is added in Table 1. This part is proposed and managed by the National Radio Interference Standardization Technical Committee (SAC/TC79). This section drafted by. China Electronics Technology Standardization Institute, Ministry of Industry and Information Technology Electronics Fifth Institute, Southeast University, Beijing Post Electric University, Beijing Jiaotong University, Beijing Radio Measurement and Testing Institute, China Institute of Metrology, Ningbo Entry-Exit Inspection and Quarantine Bureau Quarantine Technology Center, Jiangsu Institute of Metrology, China Quality Certification Center, Dalian Product Quality Inspection Institute, Tianjin Radio Monitoring Station, Shanghai Medical Device Testing Institute, Zhejiang Nuoyi Technology Co., Ltd., Zhongjiayuan (Beijing) Testing and Certification Co., Ltd., Beijing Zunguan Branch Technology Co., Ltd., Shanghai Electric Apparatus Research Institute (Group) Co., Ltd., China Automotive Engineering Research Institute Co., Ltd. The main drafters of this section. Cui Qiang, Zhu Wenli, Zhou Zhongyuan, Li Li, Wen Yinghong, Yao Lijun, Huang Pan, Xie Ming, He Peng, Deng Lingxiang, Fu Jun, Shi Dan, Cai Huaqiang, Chen Yan, Xu Wei, Liu Jingli, Jiang Sui, Zheng Yimin, Yan Xin, Wang Wei, Ye Qiongyu, Huang Xuemei, Qi Rui, Zhang Yanyan. The previous versions of the standards replaced by this section are. ---GB /Z 6113.3-2006. Radio disturbance and immunity measuring equipment And measurement method specifications Part 3. Radio disturbance and immunity Measurement technology report

1 Scope

This part of GB/T (Z) 6113 contains technical reports providing background information and supporting information for other parts of GB/T (Z) 6113 (Chapter 4). In addition, this section also gives historical information about CISPR (Special Committee on Radio Interference) and at VHF. (VHF) Range Historical reference material for measuring the interference power of household appliances and similar appliances (Chapter 5). Over the years, CISPR has produced a large number of proposals and reports, which are of great technical value, but people generally do not have it. These ones Reports and Recommendations were temporarily published in CISPR Publication No. 7 and CISPR Publication No. 8. At the CISPR meeting in Campinas, Brazil, in 1988, the CISPRA chapter focused on the content of this section, and These reports were presented in a permanent location in Part 3 of GB/T (Z) 6113, and these reports were published to show that future generations reached consensus. Note. This section consists of independent technical reports, and the symbols used may have different meanings in each chapter. This difference has been reduced to as much as possible The smallest.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 2900.77-2008 Electrotechnical terminology - Electrotechnical measurement and instrumentation - Part 1 [IEC 60050 (300-311)..2001, IDT] GB/T 2900.79-2008 Electrotechnical terminology - Electrotechnical measurement and instrumentation - Part 3 [IEC 60050 (300-313)..2001, IDT] GB/T 2900.89-2012 Electrotechnical terminology - Electrotechnical measurement and instrumentation - Part 2. General terms [IEC 60050 (300-312)..2001, IDT] GB/T 2900.90-2012 Electrotechnical terminology - Electrical and electronic measurement and instrumentation - Part 4 [IEC 60050 (300-314)..2001, IDT] GB/T 4365-2003 Electrotechnical terminology electromagnetic compatibility [IEC 60050 (161)..1990, IDT] CISPR11.2009 Industrial, Scientific and Medical (ISM) Radio Frequency Equipment Harassment Characteristics Limits and Measurement Methods (Industrial, sci- entificandmedicalequipment-Radio-frequencydisturbancecharacteristics-Limitsandmethodsof Measurement) CISPR16-1-1 Radio disturbance and immunity measuring equipment and methods of measurement - Part 1-1. Radio disturbance and immunity Measuring equipment measuring equipment (Specificationforradiodisturbanceandimmunitymeasuringapparatusand methods-Part 1-1. Radiodisturbanceandimmunitymeasuringapparatus-Measuringapparatus) ISO /IEC Guide 99.2007 Basic and general concepts of international metrology terms and related terms [Internationalvocabulary ofmetrology-Basicandgeneralconceptsandassociatedterms(VIM)]

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ6113.3-2019_English be delivered?

Answer: Upon your order, we will start to translate GBZ6113.3-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 7 ~ 11 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ6113.3-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ6113.3-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GBZ6113.3-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GBZ6113.3-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.