GBZ6113.404: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/Z 6113.404-2023 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services
| Valid |
GB/Z 6113.404-2023
|
GB/Z 6113.404-2007 | English | 1199 |
Add to Cart
|
4 days [Need to translate]
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 4-4 Uncertainties, statistics and limit modelling -- Statistics of complaints and a model for the calculation of limits
| Obsolete |
GB/Z 6113.404-2007
|
PDF similar to GBZ6113.404-2023
Basic data Standard ID | GB/Z 6113.404-2023 (GB/Z6113.404-2023) | Description (Translated English) | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services | Sector / Industry | National Standard | Classification of Chinese Standard | L06 | Classification of International Standard | 33.100 | Word Count Estimation | 106,149 | Date of Issue | 2023-11-27 | Date of Implementation | 2024-06-01 | Older Standard (superseded by this standard) | GB/Z 6113.404-2007 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GBZ6113.404-2023: Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
GB /Z 6113:404-2023: Specification for radio disturbance and immunity measurement equipment and measurement methods Part 4-4: Uncertainty, statistics and limit value modeling Statistics of complaints and limit value calculation model for the protection of radio services
ICS 33:100
CCSL06
National Standardization Guiding Technical Documents of the People's Republic of China
Replace GB /Z 6113:404-2007
Radio disturbance and immunity measurement equipment and
Measurement method specifications
Part 4-4: Uncertainty, Statistics and Limits
Modeling Complaint Statistics and Protecting Radio
Business limit calculation model
(CISPRTR16-4-4:2020,IDT)
Published on 2023-11-27 and implemented on 2024-06-01
State Administration for Market Regulation
Released by the National Standardization Administration Committee
Table of contents
Preface III
Introduction V
1 Scope 1
2 Normative references 1
3 Terms, definitions, symbols and abbreviations 1
3:1 Terms and definitions 1
3:2 Symbols and abbreviations 2
4 Complaint statistics and sources of interference 2
4:1 Introduction and History 2
4:2 The relationship between RFIs and complaints 3
4:3 A valuable indicator that tends to be lost: interference complaints 3
4:4 Compilation of statistical data on interference complaints and interference source classification recommended by CISPR 3
4:5 Interference complaint statistical format 4
5 Calculation model for limit values 8
5:1 Overview 8
5:2 Interference probability 9
5:3 Interference environment 11
5:4 Mathematical basis for calculating CISPR limits18
5:5 Application of mathematical foundations 19
5:6 Another method suitable for equipment in the frequency range of 150kHz~1GHz 26
5:7 Principles for determining CISPR limits in the frequency range above 1GHz 36
Appendix A (informative) Values of power supply decoupling coefficient in the range of 0:1MHz~200MHz (extracted from CISPR Report No: 31) 46
Appendix B (informative) Conversion of magnetic field limits at different measurement distances below 30MHz 50
Appendix C (informative) Model for estimating radiation from photovoltaic power generation systems 60
Appendix D (informative) Model for estimating radiation from indoor extra-low voltage (ELV) lighting equipment86
Reference 98
Foreword
This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
GB/T (Z) 6113 "Specification for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods" is the basic standard for electromagnetic compatibility:
This document is Part 4-4 of GB/T (Z) 6113: GB/T (Z)6113 has released the following parts:
Part 1: Radio disturbance and immunity measurement equipment
---Part 1-1: Radio disturbance and immunity measurement equipment Measuring equipment;
---Part 1-2: Coupling device for conductive disturbance measurement of radio disturbance and immunity measuring equipment;
---Part 1-3: Radio disturbance and immunity measurement equipment auxiliary equipment disturbance power;
---Part 1-4: Antennas and test sites for radiated disturbance measurements of radio disturbance and immunity measurement equipment;
---Part 1-5: Radio disturbance and immunity measurement equipment 5MHz~18GHz antenna calibration site and reference test
site;
---Part 1-6: Radio disturbance and immunity measurement equipment EMC antenna calibration:
Part 2: Radio disturbance and immunity measurement methods
---Part 2-1: Radio disturbance and immunity measurement methods Conducted disturbance measurement;
---Part 2-2: Radio disturbance and immunity measurement methods Disturbance power measurement;
---Part 2-3: Radio disturbance and immunity measurement methods Radiated disturbance measurement;
---Part 2-4: Radio disturbance and immunity measurement methods Immunity measurement;
---Part 2-5: On-site measurement of harassment emissions from large equipment:
Part 3: Radio disturbance and immunity measurement technical report
---Part 3: Radio disturbance and immunity measurement technical report:
Part 4: Uncertainty, Statistics and Limit Modeling
---Part 4-1: Uncertainty, statistics and limit value modeling Uncertainty of standardized EMC tests;
---Part 4-2: Uncertainty, statistics and limit value modeling Uncertainty of measuring equipment and facilities;
---Part 4-3: Uncertainty, Statistics and Limit Value Modeling Statistical considerations for EMC compliance determination of batch products;
---Part 4-4: Uncertainty, statistics and limit modeling Statistics of complaints and limit calculation model for protecting radio services;
---Part 4-5: Conditions for use of uncertainty, statistics and limit modeling replacement test methods:
This document replaces GB /Z 6113:404-2007 "Specification for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods Part 4-4:
Uncertainty, statistics and limit value modeling Complaint statistics and limit value calculation model", compared with GB /Z 6113:404-2007, except for structure
In addition to adjustments and editorial changes, the main technical changes are as follows:
---Added terms, definitions, symbols and abbreviations (see Chapter 3);
---Changed the "Statistics of Complaints and Sources of Interference" (see Chapter 4, Chapter 4 of the:2007 edition);
---Changed "Application of Mathematical Basics" (see 5:5,:2007 version of 5:5);
---Added "Principles for determining CISPR limits in the frequency range below 30MHz" (see 5:6:5);
---Added "limit model for the magnetic field component of disturbance field strength used to protect radio reception in the frequency range below 30MHz"
(see 5:6:6);
---Added "Principles for determining CISPR limits in the frequency range above 1GHz" (see 5:7):
This document is equivalent to CISPRTR16-4-4:2020 "Specification for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods - Part 4-4"
Points: Uncertainty, Statistics and Limit Value Modeling Statistics of Complaints and Limit Value Calculation Model for the Protection of Radio Services":
This document has made the following minimal editorial changes:
---The formulas in 5:7 have corrected formula numbers according to the order of the formulas in the text;
---In 5:3:4, a description is added that my country's sound AM broadcast operates below 29:7MHz;
---The symbols such as eir in Figure 2 and its description have been corrected from lowercase to uppercase, and the international standard is wrong;
---The protection distance stipulated by CISPR is 30m, so the "approximate equivalent interference field strength 20m away from the equipment" in Table 3 is corrected to "distance from the equipment"
Provide an approximate equivalent interference field strength of 30m”;
---"σPV" in C:2:3:3 is corrected to "σCPV":
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
This document is proposed and coordinated by the National Radio Interference Standardization Technical Committee (SAC/TC79):
This document was drafted by: China Electronics Technology Standardization Institute, Shenzhen Beida Testing Technology Co:, Ltd:, Beijing Jiaotong University, Southeast
Universities, the Fifth Institute of Electronics of the Ministry of Industry and Information Technology, China Institute of Metrology, Beijing University of Posts and Telecommunications, and China Automotive Engineering Research Institute
Co:, Ltd:, Shanghai Electrical Apparatus Research Institute (Group) Co:, Ltd:, Nanjing Normal University, China National Accreditation Center for Conformity Assessment, Guangzhou Chengdu
Zhen Electronic Technology Co:, Ltd:, Zhejiang Nuoyi Technology Co:, Ltd:, China Electric Power Research Institute Co:, Ltd:, China Institute of Technology (Beijing) testing and certification
Co:, Ltd:, National Radio Monitoring Center, Guangzhou Saibao Measurement and Testing Center Service Co:, Ltd:, Jiangsu Institute of Metrology, Shanghai
Measurement and Testing Technology Research Institute, Dalian Product Quality Inspection and Testing Research Institute Co:, Ltd:, Zhejiang Longchuang Motor Technology Innovation Co:, Ltd:, National
Radio Monitoring Center Testing Center:
The main drafters of this document: Cui Qiang, Chen Zhengyu, Wen Yinghong, Fu Jun, Zhou Yehua, Zhou Zhongyuan, Zhu Wenli, Li Zhipeng, Xie Ming, Shi Dan,
Sun Meiqiu, Huang Xuemei, Li Li, Xing Lin, Yan Wei, Long Yue, Li Nan, Zheng Yimin, Li Ni, Qi Xin, Li Yiming, Yuan Xiaoxi, Chen Yan, Deng Lingxiang,
Li Jinlong, Xu Dan, Zhou Haibin, Wang Wenjian:
The previous versions of this document and the documents it replaces are as follows:
---First released as GB /Z 6113:404-2007 in:2007;
---This is the first revision:
Introduction
In order to standardize electromagnetic compatibility measurements, consider measurement uncertainties and provide background information related to measurements, as well as label electromagnetic compatibility products:
The standard formulation and revision lays a technical foundation: GB/T (Z) 6113 specifies radio disturbance and immunity measurement equipment, measurement methods, and measurement uncertainty:
Qualification technical requirements and a model for calculating limits, which consists of four parts: Part 1 is the specifications for radio disturbance and immunity measurement equipment;
Part 2 is the specification for radio disturbance and immunity measurement methods; Part 3 is the technical report on radio disturbance and immunity measurement; Part 4
Divided into uncertainty, statistics and limit modeling:
Part 4 is divided into 5 parts:
---Part 4-1: Uncertainty of standardized EMC tests: The purpose is to provide electromagnetic compatibility standard setters and revisers with
Guidance on dealing with uncertainty:
---Part 4-2: Uncertainty of measuring equipment and facilities: The purpose is to provide for testing of equipment under test based on CISPR harassment limits:
How to apply the uncertainty of measuring equipment and facilities (MIU) method when making conformity determinations:
---Part 4-3: Statistical considerations for determination of EMC compliance of batch products: The purpose is to describe and determine the electromagnetic compatibility of batch products
(EMC) Statistical considerations for compliance:
---Part 4-4: Complaint statistics and limit calculation model for protecting radio services: The purpose is to show how to deal with radio
Suggestions on interference complaint statistics and calculation of limit values for disturbance field strength and disturbance voltage measurements at the test site:
---Part 4-5: Conditions for use of replacement test methods: The purpose is to provide product committees with information when using alternative test methods:
Conversion method between established test method limits:
Radio disturbance and immunity measurement equipment and
Measurement method specifications
Part 4-4: Uncertainty, Statistics and Limits
Modeling Complaint Statistics and Protecting Radio
Business limit calculation model
1 Scope
This document gives suggestions on how to handle radio interference complaint statistics, describing disturbances based on radiated coupling and conducted coupling respectively:
model to calculate the limits of disturbance field strength and disturbance voltage measurements at the test site:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document:
Note: GB/T 4365-2003 Electrical terminology electromagnetic compatibility [IEC 60050(161):1990,IDT]
CISPR11 Radio frequency disturbance characteristics limits and measurement methods for industrial, scientific and medical radio frequency equipment (Industrial, scientific and medical
urement)
Note: GB 4824-2019 Radio frequency disturbance characteristics limits and measurement methods for industrial, scientific and medical equipment (CISPR11:2016, IDT)
3 Terms, definitions, symbols and abbreviations
3:1 Terms and definitions
The terms and definitions defined in IEC 60050-161 and the following apply to this document:
3:1:1
complaincomplaint
Radio Frequency Interference Investigations by users of radio receiving equipment due to reduced reception performance due to radio frequency interference
Requests for help from service agencies:
3:1:2
An agency that operates nationwide and is tasked with investigating reported cases of radio frequency interference:
Examples: radio service operators, cable television network operators, regulatory or regulatory authorities:
3:1:3
source source
Any type of interference that can cause radio frequency interference (RFI) to certain radio receiving equipment:
Part of an electrical or electronic equipment, system or installation:
|