GB/T 6113.103-2021 PDF in English
GB/T 6113.103-2021 (GB/T6113.103-2021, GBT 6113.103-2021, GBT6113.103-2021)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 6113.103-2021 | English | 410 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbances power
| Valid |
GB/T 6113.103-2008 | English | 170 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-3: Radio disturbance and immunity measuring apparatus -- Ancillary equipment -- Disturbances power
| Obsolete |
Standards related to (historical): GB/T 6113.103-2021
PDF Preview
GB/T 6113.103-2021: PDF in English (GBT 6113.103-2021) GB/T 6113.103-2021
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 33.100
CCS L 06
GB/T 6113.103-2021 / CISPR 16-1-3:2016
Replacing GB/T 6113.103-2008
Specification for radio disturbance and immunity
measuring apparatus and methods - Part 1-3: Radio
disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbances power
(CISPR 16-1-3:2016, IDT)
ISSUED ON: MAY 21, 2021
IMPLEMENTED ON: DECEMBER 01, 2021
Issued by: State Administration for Market Regulation;
Standardization Administration of the PRC.
Table of Contents
Foreword ... 3
Introduction ... 7
1 Scope ... 8
2 Normative references ... 8
3 Terms, definitions and abbreviations ... 9
3.1 Terms and definitions ... 9
3.2 Abbreviations ... 9
4 Absorbing clamp instrumentation ... 9
4.1 Introduction ... 9
4.2 The absorbing clamp assembly ... 10
4.3 The absorbing clamp assembly calibration methods and their relations ... 13
4.4 The secondary absorbing device ... 15
4.5 The absorbing clamp test site (ACTS) ... 16
4.6 Quality assurance procedures for the absorbing clamp instrumentation ... 18
Annex A (Informative) Construction of the absorbing clamp (Subclause 4.2) 23
Annex B (Normative) Calibration and validation methods for the absorbing
clamp and the secondary absorbing device (Clause 4) ... 26
Annex C (Normative) Validation of the absorbing clamp test site (Clause 4) . 36
Bibliography ... 39
Foreword
This document is drafted in accordance with GB/T 1.1-2020 "Directives for
standardization - Part 1: Rules for the structure and drafting of standardizing
documents".
GB/T(Z) 6113 "Specification for radio disturbance and immunity measuring
apparatus and methods" is the basic standard of electromagnetic compatibility.
This document is Part 1-3 of GB/T(Z) 6113. GB/T(Z) 6113 has issued the
following parts:
Part 1: Radio disturbance and immunity measuring apparatus
- Part 1-1: Radio disturbance and immunity measuring apparatus -
Measuring apparatus;
- Part 1-2: Radio disturbance and immunity measuring apparatus -
Coupling devices for conducted disturbance measurements;
- Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbances power;
- Part 1-4: Radio disturbance and immunity measuring apparatus -
Antennas and test sites for radiated disturbance measurements;
- Part 1-5: Radio disturbance and immunity measuring apparatus -
Antenna calibration sites and reference test sites for 5 MHz to 18 GHz;
- Part 1-6: Radio disturbance and immunity measuring apparatus - EMC
antenna calibration.
Part 2: Methods of measurement of disturbances and immunity
- Part 2-1: Methods of measurement of disturbances and immunity -
Conducted disturbance measurements;
- Part 2-2: Methods of measurement of disturbances and immunity -
Measurement of disturbance power;
- Part 2-3: Methods of measurement of disturbances and immunity -
Radiated disturbance measurements;
- Part 2-4: Methods of measurement of disturbances and immunity -
Immunity measurements;
- Part 2-5: In situ measurements of disturbing emissions produced by
physically large equipment.
Part 3: CISPR technical reports
- Part 3: CISPR technical reports.
Part 4: Uncertainties, statistics and limit modelling
- Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in
standardized EMC tests;
- Part 4-2: Uncertainties, statistics and limit modelling - Measurement
instrumentation uncertainty;
- Part 4-3: Uncertainties, statistics and limit modelling - Statistical
considerations in the determination of EMC compliance of mass-
produced products;
- Part 4-4: Uncertainties, statistics and limit modelling - Statistics of
complaints and a model for the calculation of limits;
- Part 4-5: Uncertainties, statistics and limit modelling - Conditions for the
use of alternative test methods.
This document replaces GB/T 6113.103-2008 "Specification for radio
disturbance and immunity measuring apparatus and methods - Part 1-3: Radio
disturbance and immunity measuring apparatus - Ancillary equipment -
Disturbances power". Compared with GB/T 6113.103-2008, in addition to
structural adjustments and editorial changes, the main technical changes are
as follows:
- Update the normative references (see Clause 2; Clause 2 of the 2008
edition);
- Delete the abbreviation "reference conversion factor" (see 3.2 of the 2008
edition);
- Delete the content related to the "reference device method" (see 4.3 of the
2008 edition);
- Modify Figures B.3 and B.4 (see Annex B; Annex B of the 2008 edition);
- Add Figure B.5b) (see Annex B).
This document, using translation method, is identical to CISPR 16-1-3:2016
"Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbance power".
China’s documents which have a consistent correspondence with the
international documents normatively referenced in this document are as follows:
- GB/T 6113.102-2018 Specification for radio disturbance and immunity
measuring apparatus and methods - Part 1-2: Radio disturbance and
immunity measuring apparatus - Coupling devices for conducted
disturbance measurements (CISPR 16-1-2:2014, IDT)
- GB/T 6113.202-2018 Specification for radio disturbance and immunity
measuring apparatus and methods - Part 2-2: Methods of measurement of
disturbances and immunity - Measurement of disturbance power (CISPR
16-2-2:2010, IDT)
- GB/T 6113.402-2018 Specification for radio disturbance and immunity
measuring apparatus and methods - Part 4-2: Uncertainties, statistics and
limit modelling - Measurement instrumentation uncertainty (CISPR 16-4-
2:2014, IDT)
The following editorial change has been made to this document:
- In order to facilitate the reader's citation, change the CISPR NSA in the
international standard B.2.1.1 to reference to the GB/T 6113.104-2016 NSA
requirements and include it in Clause 2.
Attention is drawn to the possibility that some of the elements of this document
may be the subject of patent rights. The issuing authority of this document shall
not be held responsible for identifying any or all such patent rights.
This document was proposed by and shall be under the jurisdiction of National
Technical Committee 79 on Radio Interference of Standardization
Administration of China (SAC/TC 79).
Drafting organizations of this document: China Electronics Standardization
Institute; Suzhou 3ctest Electronic Co., Ltd.; National Institute of Metrology,
China; Xiamen H-noble Scientific Instruments Co., Ltd.; Beijing Zhinan
Technology Co., Ltd.; China National Accreditation Service for Conformity
Assessment; China Household Electric Appliance Research Institute; The Fifth
Electronics Research Institute of the Ministry of Industry and Information
Technology; Southeast University; Beijing TIRT Technology Service Co., Ltd.;
ATS Technology Limited.; Dalian Inspection Research Institute of Product
Quality Co., Ltd.; Jiangsu Electronic Information Product Quality Supervision &
Inspection Institute; GZ CHANGEN Electronic Technology Co., Ltd.; Zhejiang
Noyetec Technology Co., Ltd.; China Automotive Engineering Research
Institute Co., Ltd.; CEPREI Calibration & Testing Center; Ningbo Customs
Technology Center; Jiangsu Institute of Metrology; CVC Certification & Testing
Co., Ltd.; Guangdong CQC South China Testing Technology Co., Ltd.;
Specification for radio disturbance and immunity
measuring apparatus and methods - Part 1-3: Radio
disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbances power
1 Scope
This document specifies the characteristics and calibration of the absorbing
clamp for the measurement of radio disturbance power in the frequency range
30 MHz to 1 GHz.
2 Normative references
The contents of the following documents, through normative references in this
text, constitute indispensable provisions of this document. Among them, for
dated references, only the edition corresponding to that date applies to this
document. For undated references, the latest edition (including all amendments)
applies to this document.
GB/T 4365-2003 Electrotechnical terminology - Electromagnetic
compatibility [IEC 60050(161):1990+A1:1997+A2:1998, IDT]
GB/T 6113.104-2016 Specification for radio disturbance and immunity
measuring apparatus and methods - Part 1-4: Radio disturbance and
immunity measuring apparatus - Antennas and test sites for radiated
disturbance measurements (CISPR 16-1-4:2012, IDT)
CISPR 16-1-2:2003 Specification for radio disturbance and immunity
measuring apparatus and methods - Part 1-2: Radio disturbance and
immunity measuring apparatus - Ancillary equipment - Conducted
disturbances
CISPR 16-2-2:2003 Specification for radio disturbance and immunity
measuring apparatus and methods - Part 2-2: Methods of measurement of
disturbances and immunity - Measurement of disturbance power
CISPR 16-4-2 Specification for radio disturbance and immunity measuring
apparatus and methods - Part 4-2: Uncertainties, statistics and limit
modelling - Measurement instrumentation uncertainty
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|