US$139.00 · In stock Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 9727-2007: Chemical reagent -- General method for the determination of phosphate Status: Valid GB/T 9727: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 9727-2007 | English | 139 |
Add to Cart
|
2 days [Need to translate]
|
Chemical reagent -- General method for the determination of phosphate
| Valid |
GB/T 9727-2007
|
GB/T 9727-1988 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Chemical reagent--General method for the determination of phosphate
| Obsolete |
GB/T 9727-1988
|
PDF similar to GB/T 9727-2007
Basic data Standard ID | GB/T 9727-2007 (GB/T9727-2007) | Description (Translated English) | Chemical reagent -- General method for the determination of phosphate | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | G60 | Classification of International Standard | 71.040.30 | Word Count Estimation | 5,558 | Date of Issue | 2007-09-26 | Date of Implementation | 2008-04-01 | Older Standard (superseded by this standard) | GB/T 9727-1988 | Adopted Standard | ISO 6353-1-1982, NEQ | Regulation (derived from) | China National Standard Approval Announcement2007 No.11 (Total No.111) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard provides a common method for the determination of phosphate extracted using a phosphorus molybdenum blue colorimetric method. This standard applies to chemical agents trace determination of orthophosphate. Spectrophotometric or visual colorimetric detection range in butyl acetate was 0. 2��g/mL ~ 2��g/mL (as PO4). |
GB/T 9727-2007: Chemical reagent -- General method for the determination of phosphate---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical reagent. General method for the determination of phosphate
ICS 71.040.30
G60
National Standards of People's Republic of China
Replacing GB/T 9727-1988
Chemical Reagents
General method for the determination of phosphate
(ISO 6353-1. 1982, Reagentsforchemicalanalysis-
Part 1. Generaltestmethods, NEQ)
Posted 2007-09-26
2008-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard and ISO 6353-1. 1982 "Reagents for chemical analysis - Part 1. General test method" non-equivalent.
This standard replaces GB/T 9727-1988 "General method for the determination of phosphate chemical reagents."
This standard did not differ from the 1988 edition of the standard in technical content, according to GB/T 1.1-2000 requirements, just to do some editing
Modifications.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee Chemistry Chemicals Branch (SAC/TC63/SC3) centralized.
This standard was drafted. Sinopharm Chemical Reagent Co., Ltd.
The main drafters of this standard. Chenhao Yun, Chen Hong.
This standard was first published in 1988.
Chemical Reagents
General method for the determination of phosphate
1 Scope
This standard specifies the use Extraction - Determination of phosphate phosphorus molybdenum blue colorimetric common method.
This standard applies to chemical agents trace determination of orthophosphate. Spectrophotometric or visual colorimetric detection range in butyl acetate
For 0.2μg/mL ~ 2μg/mL (in PO4 dollars).
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 602 Determination of impurities in chemical reagents prepared standard solution (GB/T 602-2002, ISO 6353-1. 1982, NEQ) with
GB/T 603 chemical reagent test method Preparations of articles (GB/T 603-2002, ISO 6353-1 with. 1982,
NEQ)
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-1992, neq ISO 3696. 1987)
GB/T 9721 Chemicals General molecular absorption spectrophotometry (UV and visible part)
3 PRINCIPLE OF THE METHOD
The concentration of Ba (HNO3) is 0.4mol/L ~ 1.4mol/L solution of nitric acid, phosphoric acid and ammonium molybdate quantitatively, generating phosphomolybdate
Acid (phosphorus molybdenum yellow), yellow phosphorus and molybdenum may be butyl acetate from 1.0mol/L ~ 1.4mol/L nitric acid solution quantitatively extracted, thereby interfering with the compound
Excess reagent was arsenate and molybdate separation. Added stannous chloride - ascorbic acid solution, the phosphorus reduced to phosphorus molybdenum yellow and molybdenum blue. According phosphorus molybdenum blue
Shades of color that can be used visual colorimetry or spectrophotometry phosphate.
4 Reagents and materials
Unless otherwise specified in this standard, the standard solution, preparations and products, according to GB/T 602, the provisions of the preparation of GB/T 603, the experimental
Water should be consistent with GB/T 6682 water in three specifications, are the mass fraction of the solution used in "%" represents.
5 Instruments
5.1 General laboratory equipment.
5.2 Spectrophotometer shall comply with GB/T 9721's.
6 Determination
6.1 visual colorimetry
Sampling according to product standards and the preparation of test solution (if necessary with 2 drops of saturated 2,4-dinitrophenol indicator solution as indicator the solution was adjusted
pH value). Test solution of 10mL, 10mL added nitric acid solution (13%), then the solution of Ba acidity (H +) was 1.0mol/L ~ 1.2mol/L.
Add 2mL ammonium molybdate solution (100g/L), placed 20min. Butyl acetate was added 10mL accurate extraction rested stratification. The aqueous phase was discarded,
The organic phase was washed with a solution (5%) hydrochloric acid and washed twice, each 5mL, the aqueous phase was separated. Stannous chloride in the organic phase was added 0.2mL - ascorbic acid
Solution, gently shake rested stratification. The aqueous phase was discarded, ethanol is added 1mL, shake. The organic phase was blue with the standard colorimetric solution
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 9727-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 9727-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 9727-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 9727-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 9727-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9727-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|