US$859.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 8287.2-2008: Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V -- Part 2: Dimensions and characteristics Status: Valid GB/T 8287.2: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 8287.2-2008 | English | 859 |
Add to Cart
|
6 days [Need to translate]
|
Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V -- Part 2: Dimensions and characteristics
| Valid |
GB/T 8287.2-2008
|
| GB/T 8287.2-1999 | English | 639 |
Add to Cart
|
5 days [Need to translate]
|
High voltage post insulators of ceramic material. Part 2: Dimensions and characteristics
| Obsolete |
GB/T 8287.2-1999
|
| GB/T 8287.2-1987 | English | RFQ |
ASK
|
3 days [Need to translate]
|
High voltage post insulators of ceramic material--Dimensions and characteristics
| Obsolete |
GB/T 8287.2-1987
|
PDF similar to GB/T 8287.2-2008
Basic data | Standard ID | GB/T 8287.2-2008 (GB/T8287.2-2008) | | Description (Translated English) | Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V -- Part 2: Dimensions and characteristics | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K48 | | Classification of International Standard | 29.080.10 | | Word Count Estimation | 39,33 | | Date of Issue | 2008-06-30 | | Date of Implementation | 2009-04-01 | | Older Standard (superseded by this standard) | GB 12744-1991; GB/T 8287.2-1999 | | Adopted Standard | IEC 60273-1990, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to a nominal voltage greater than 1000V, frequency does not exceed 100Hz AC electrical devices running on the system or equipment used for indoor or outdoor pillar of porcelain or glass insulators and their components, as well as indoor post insulators of organic material. This section can also be used as a DC system Insulator provisional standards. This section includes the insulator is mainly used for isolating switches, breakers, and fuses and other electrical equipment. |
GB/T 8287.2-2008: Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V -- Part 2: Dimensions and characteristics ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V. Part 2. Dimensions and characteristics
ICS 29.080.10
K48
National Standards of People's Republic of China
Replacing GB/T 8287.2-1999, GB 12744-1991
The nominal voltage greater than 1000 system users and Vp
Outdoor post insulators - Part 2. Dimensions and characteristics
(IEC 60273.1990, Characteristicsofindoorandoutdoorpostinsulators
forsystemswithnominalvoltagesgreaterthan1000V, MOD)
Posted 2009-04-01 2008-06-30 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Purpose and scope 1
1.1 Scope 1
1.2 Objective 1
1.3 Terms and Definitions 1
2 Normative references 1
3 Electrical Characteristics 2
Mechanical properties 2 4
3 5 Dimensional characteristics
6 mounting structure 4
7 Standard Features 5
8 post insulator type 5
Appendix A (informative) outdoor post insulators needle assembly example 27
Annex B (informative) of this section with IEC 60273.1990 technical differences and their causes 32
Annex C (informative) of this section with IEC 60273.1990 reg control number 33
Appendix D (Informative Appendix) GB/T 8287.2-1999 domestic product line 34
Foreword
GB/T 8287 "nominal voltage greater than 1000V system and outdoor post insulators" is currently divided into two parts.
--- Part 1. Test porcelain or glass insulators;
--- Part 2. Dimensions and characteristics.
This section GB/T 28287 Part of.
The partial modification of the use of IEC 60273.1990 "with a nominal voltage of 1000V system users and outdoor post insulators for special
Sex "(in English).
This section and the IEC 60273.1990 technical differences in terms of which they are involved in the margin of a single vertical line identification, Appendix
B gives a list of the technical differences and their causes, Annex C of this section and the IEC 60273.1990 clauses table.
For ease of use, this section also made the following editorial changes.
a) "this International Standard" be replaced by "this section";
b) use a decimal point instead of a decimal point ",". ",";
c) Remove the preface to international standards and references.
This section incorporates GB/T 8287.2-1999 "High voltage post insulators Part 2. Dimensions and characteristics" and GB 12744-
1991 "Fog type outdoor post insulators of ceramic rod" content.
This section and GB/T 8287.2-1999 and GB 12744-1991 main differences are.
--- Text format, layout, and other clauses in accordance with IEC 60273.1990, and GB/T 8287.2-1999 and GB 12744-1991 End
Entirely different;
--- The main characteristics of post insulators characterized by a rated voltage to impulse voltage;
--- Complement the characteristic values \u200b\u200b550kV insulator, increasing the value of properties and 1100kV 800kV insulators;
In order to maintain the integrity of the text --- Reserved IEC 60273.1990 the entire contents, in particular to extend the scope of a standard indoor
Pillar of organic material insulator;
--- Rod post insulators for outdoor set up four minimum creepage distance rating.
Appendix D lists the GB/T 8287.2-1999 original series features to reference in this part.
This part of the Annex A, Annex B, Annex C and Annex D are informative appendices.
This part is proposed by the China Electrical Equipment Industrial Association.
The insulators in part by the National Standardization Technical Committee (SAC/TC80) centralized.
This part mainly drafted by. high-voltage porcelain Ltd. Tangshan, Xi'an Institute of Electric Porcelain, West An Shuangjia high-voltage ceramic Electric Co.,
Suzhou Electric Porcelain Co., Ltd., Xi'an high-voltage electrical porcelain limited liability company, the National Insulator arrester Quality Supervision and Inspection Center.
The main drafters of this section. Yang Ming, Yao Junrui, Ych-Er Chen, Lu Zhou, Li Tainan, later to Li, Liu Zhanmin, Wei Peng.
This part of the standard replaces the previous editions.
--- GB 8287.2-1987, GB/T 8287.2-1999.
--- GB 12744-1991.
The nominal voltage greater than 1000 system users and Vp
Outdoor post insulators - Part 2. Dimensions and characteristics
1 Purpose and scope
1.1 Scope
This section GB/T 8287 applies to the nominal voltage above 1000V, frequency does not exceed the electrical system of 100Hz AC running
Indoor or outdoor post insulators and ceramic or glass element device or equipment, as well as indoor post insulators of organic material. This section also
It can be used as the interim standard DC system with post insulators.
This section includes the main insulator for isolating switches, circuit breakers, fuses and other electrical equipment and buses.
This section includes five types of post insulators.
a) within indoors with plastic or glass pillar porcelain insulators;
b) in the indoor post insulators of organic material with plastic;
c) Binding cylindrical pillar within the outdoor porcelain or glass insulators;
d) with plastic outer cylindrical pillar outdoor porcelain or glass insulators;
e) Outdoor needle pillar porcelain or glass insulators.
The term "cylindrical insulators" also includes a truncated cone insulators.
This section includes five types of insulators their electrical, mechanical and dimensional characteristics classification. Figures 1, 2, 3, 4 and 5 respectively,
Each insulator typical legend.
These figures only give a general description, allows the use of other shapes and configurations.
1.2 Purpose
The purpose of this section is to provide the electrical characteristics of post insulators, mechanical properties and dimensional characteristics values. The property values \u200b\u200bare the same size type pillar
Its realization insulator element basis interchangeable.
NOTE. General definitions and test methods for porcelain and glass insulators see GB/T 8287.1-2008, general definitions and test methods for organic material insulator
See JB/T 10305.
1.3 Terms and Definitions
Terms and definitions GB/T 2900.8-1995 and GB/T 8287.1-2008 established applicable to this section.
2 Normative references
The following documents contain provisions which, through reference to GB/T 8287 to the present, constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 197-2003 common thread tolerance (ISO 965-1.1998, MOD)
GB 311.1-1997 insulation with high voltage power transmission equipment (neqIEC 60071-1.1993)
GB/T 1800.4-1999 Limits and fits standard tolerance grades and limit deviations for holes and shafts of (eqv ISO 286-2. 1988)
GB/T 2900.8-1995 Electrotechnical terminology insulator (IEC 60050-471, MOD)
GB/T 8287.1-2008 nominal voltage greater than 1000V system and outdoor post insulators - Part 1. Ceramic or glass
Glass insulators test (IEC 60168.2001, MOD)
IEC 60071-1.1993 insulation coordination - Part 1. Definitions, principles and rules
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 8287.2-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 8287.2-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 8287.2-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 8287.2-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 8287.2-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 8287.2-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|