HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Sep 2024)

GB/T 7106-2008 English PDF

GB/T 7106-2008 (GB/T7106-2008, GBT 7106-2008, GBT7106-2008)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 7106-2008English879 Add to Cart 4 days [Need to translate] Graduations and test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors Obsolete GB/T 7106-2008
GB/T 7106-2019English599 Add to Cart 5 days [Need to translate] Test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors Valid GB/T 7106-2019
Newer version: GB/T 7106-2019    Standards related to: GB/T 7106-2019

BASIC DATA
Standard ID GB/T 7106-2008 (GB/T7106-2008)
Description (Translated English) Graduations and test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Q70
Classification of International Standard 91.060.50
Word Count Estimation 22,258
Date of Issue 2008-07-30
Date of Implementation 2009-03-01
Older Standard (superseded by this standard) GB/T 13685-1992; GB/T 13686-1992; GB/T 7106-2002; GB/T 7107-2002; GB/T 7108-2002
Quoted Standard GB/T 5823; GB 50009; GB/T 50178
Adopted Standard ISO 6612-1980 (E), NEQ; ISO 6613-1980 (E), NEQ
Drafting Organization China Academy of Building Research
Administrative Organization Department of Housing and Urban building products and product components and parts Standardization Technical Committee
Regulation (derived from) National Standard Approval Announcement 2008 No.12 (Total No.125)
Proposing organization Ministry of Housing and Urban-Rural Development of the People's Republic of China
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the building exterior doors airtight, terms and definitions watertight and wind pressure performance, classification, detection device, detecting preparations, airtight performance testing, watertight performance testing, wind pressure performance test and inspection reports. This standard applies to air tightness of windows and external doors, watertight, wind resistance performance classification and laboratory testing. Detection target specimen itself only windows, doors and does not involve other parts of the joint structure.

GB/T 7106-2008 Graduations and test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors ICS 91.060.50 Q70 National Standards of People's Republic of China Replacing GB/T 7106 ~ 7108-2002, GB/T 13685 ~ 13686-1992 Building external doors and windows airtight, watertight, wind pressure Performance classification and test method (ISO 6612. 1980 (E) Windowsanddoorheightwindows-Windresistancetests, ISO 6613. 1980 (E) Windowsanddoorheightwindows- Airpermeabilitytest, NEQ) Posted 2008-07-30 2009-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Foreword This standard and ISO 6612-1980 "on the windows and door height windows --- wind pressure test", ISO 6613-1980 "on the windows and door height windows --- Air permeability test, "the non-equivalent. The performance of wind pressure standard detection methods on the deformation and repeated pressurization and safety requirements and testing procedures and requirements of ISO 6612-1980 Consistent with an increase of P1, P2, and requiring multiple relationships compression speed of P3; the tightness of the standard detection methods in the detection principle, detection The detection and calculation means and the amount of air infiltration specimen is consistent with the requirements of ISO 6613-1980, increasing the pressure difference detection classification, Pressure conversion method, pressurizing speed requirements. This standard replaces GB/T 7106-2002 "of windows wind pressure performance classification and test methods", GB/T 7107-2002 "outside the building Window airtight performance classification and test methods ", GB/T 7108-2002" of windows watertight performance classification and test methods ", GB/T 13685- Air permeability 1992 "wind pressure deformation properties and test methods for building external doors" and GB/T 13686-1992 "building external doors And rain properties and test methods "leakage. And GB/T 7106-2002, GB/T 7107-2002, GB/T 7108-2002, GB/T 13685-1992 and GB/T 13686- Compared to 1992, this standard main modifications are as follows. --- The building external windows, external doors airtight, watertight, wind resistance performance rating and testing methods for unity. --- External doors grading performance, detection methods were unified and outside the window. --- Modify the watertight performance of wind pressure at the highest level of representation. --- Clear layout and calculation methods measured deflection point single-leaf single point locking doors and windows wind pressure performance test. --- Clear outer doors and windows and glass rod maximum allowable deflection detection method using different glass. --- Modify the accuracy tightness testing. --- Modify the tightness classification table. --- Increased tightness detection device, water spray system calibration method. --- Appendix increased sample test report. This standard Annex A, Annex B, Annex C is informative appendix. The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard is under the jurisdiction of the Ministry of Construction of housing construction product standards and products, components and technical committees urban and rural areas. This standard is drafted by. China Academy of Building Research. Participated in the drafting of this standard. Guangdong Provincial Academy of Building Research, Henan Academy of Building Research, Fujian Academy of Building Research, National Home Building Materials Testing Center, Guangzhou Institute of Building Sciences, Jiangsu Construction Engineering Quality Inspection Center Co., Ltd., Shanghai Branch Building Research Institute Ltd., Jiangsu Health Luo Kedi (Shanghai) Co., Ltd., Beijing Jin Yi cell wall decoration Engineering Co., Ltd., Fujian Province Nanping Aluminum Co., Ltd., Dongguan, Guangdong Province, Kennedy Long Metal Products Co., Ltd. The main drafters of this standard. Wang Hongtao, Liuhui Tao, Zhang Shixiang, Ji Weiming, Chen Dewei, Liu Haibo, Liu Xiaosong, Zhang Yunlong, left Wei Wen, Lugano Chi, class Guangsheng, Xie Guangyu, Duwan Ming. This standard replaces the standards previously issued as follows. --- GB/T 7106-1986, GB/T 7106-2002; --- GB/T 7107-1986, GB/T 7107-2002; --- GB/T 7108-1986, GB/T 7108-2002; --- GB/T 13685-1992; --- GB/T 13686-1992. Building external doors and windows airtight, watertight, wind pressure Performance classification and test method 1 Scope This standard specifies the terms and definitions building external doors and windows airtight, watertight and wind pressure performance, classification, detection means for detecting ready, airtight Performance testing, performance testing water tightness, wind resistance performance testing and test report. This standard applies to the outside of windows and doors airtight, watertight, wind resistance performance rating and laboratory testing. Object detection is limited to windows and doors The specimen itself, does not involve the joint portion between the doors and windows and other structures. 2 Normative references The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 5823 building windows and doors term GB 50009 building structural load specifications GB/T 50178 building climate zoning standards 3 Terms and Definitions GB/T 5823 and identified the following terms and definitions apply to this standard. 3.1 Building exterior doors and exterior windows collectively. 3.2 Indoor and outside doors and windows, the outer surface of the air by the difference between the absolute pressure. When the outdoor surface is higher than the pressure on the indoor surface suffered pressure The force, the pressure difference is positive; otherwise it is negative. 3.3 External doors and windows closed in the normal state, the ability to prevent air infiltration 3.3.1 Temperature of 293K (20 ℃), a pressure of 101.3kPa (760mmHg), air density 1.202kg/m3 test condition. 3.3.2 Under standard conditions, the amount of air per unit time through the entire window (door) specimens. 3.3.3 In addition to the amount of air infiltration test piece itself, the connection portion of the amount of air infiltration through the device and the test specimen box. ...