GB/T 31433-2015 PDF in English
GB/T 31433-2015 (GB/T31433-2015, GBT 31433-2015, GBT31433-2015)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 31433-2015 | English | 245 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
General specification for building curtain walls, windows and doors
| Valid |
Standards related to (historical): GB/T 31433-2015
PDF Preview
GB/T 31433-2015: PDF in English (GBT 31433-2015) GB/T 31433-2015
GB
NATIONAL STANDARD OF THE
PEOPLE'S REPUBLIC OF CHINA
ICS 91.060
P 32
General specification for building curtain walls,
windows and doors
ISSUED ON: APRIL 22, 2015
IMPLEMENTED ON: DECEMBER 01, 2015
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of PRC;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Terms and definitions ... 7
4 Performance classification and selection ... 7
5 Requirements ... 8
6 Test ... 17
Appendix A (Normative) Correlation of performance and components ... 20
General specification for building curtain walls,
windows and doors
1 Scope
This standard specifies the performance classification and selection,
requirements and tests of building curtain walls, doors and windows.
This standard applies to curtain walls, doors and windows, for civil buildings.
This standard does not apply to the external wall decoration systems, whose
panels are directly pasted to the main structure AND the external wall dry
hanging systems without supporting frame structures. It does not apply to
special doors and windows, such as fire doors and windows, escape doors and
windows, smoke exhaust windows, radiation shielding doors and windows.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) is applicable to this standard.
GB/T 2680 Determination of light transmittance, solar direct transmittance,
total solar energy transmittance and ultraviolet transmittance for glass in
building and related glazing factors
GB/T 5823 Terminology for building windows and doors
GB/T 7106 Graduations and test methods of air permeability watertightness
wind load resistance performance for building external windows and doors
GB/T 8484 Graduation and test method for thermal insulating properties of
doors and windows
GB/T 8485 The graduation and test for airborne sound insulating properties
of windows and doors
GB/T 9158 Test methods of mechanics performance for windows and doors
in building
GB/T 11976 Graduation and test method of daylighting properties for
external windows
GB/T 12513 Fire-resistance tests - Elements of building construction -
Glazed elements
GB/T 14155 Doorsets - Soft heavy body impact test
GB/T 15227 Test method of air permeability, watertightness, wind load
resistance performance for curtain walls
GB 15763.1 Safety glazing materials in building - Part 1: Fire-resistant glass
GB 15763.4 Safety glazing materials in building - Part 4: Heat soaked
thermally tempered glass
GB 16776 Structural silicon sealants for building
GB/T 18091 Optical and thermal performance of glass curtain wall
GB/T 18250 Graduations and test method for performance of deformation
between stories of curtain wall
GB/T 21086 Curtain wall for building
GB/T 29043 Graduation and test method for thermal insulating properties of
curtain walls
GB/T 29049 Doorsets - Vertical load test
GB/T 29530 Hinged or pivoted doors - Determination of the resistance to
static torsion
GB/T 29737 Graduations and test method of sand and dust resistance
performance for building external windows and doors
GB/T 29738 Graduations and test method for performance of exterior
windows and doors, curtain walls impacted by windborne debris in
windstorm
GB/T 29739 Test method of resistance to repeat opening and closing for
windows and doors
GB/T 29908 Classification and test method of air-blast resistance
performance for curtain walls, windows and doors
GB/T 30591 Requirements for size coordination for opening of windows and
doors in building
GB 50016 Code of design on building fire protection and prevention
GB 50057 Design code for protection of structures against lightning
JG/T 397 Test method for thermal cycling of curtain walls
JGJ 102 Technical code for glass curtain wall engineering
JGJ/T 151 Calculation specification for thermal performance of windows,
doors and glass curtain-walls
ISO 15822 Test method of door set opening performance in diagonal
deformation - Seismic aspects
3 Terms and definitions
The terms and definitions as defined in GB/T 5823 and GB/T 21086, as well as
the following terms and definitions, apply to this document.
3.1
Similar design
Characteristics of the design of curtain walls, doors and windows profiles,
glass, hardware and other parts or assembly methods, the change of which
does not cause performance changes.
3.2
Representative sample
A sample, that can represent the performance test results of similar curtain
walls, doors and windows, with similar design.
3.3
Fire resistant integrity of windows and doors
Under the standard fire resistance test conditions, the ability to prevent
flames and hot gas, from penetrating or appearing on the fire-back side,
within a certain period of time, when one side of a building's doors and
windows is exposed to fire.
4 Performance classification and selection
The performance classification and selection of curtain walls, doors and
windows shall meet the requirements of Table 1.
standards.
5.1.2 The design service life of main components, such as building curtain walls,
door and window panels, profiles, etc. shall not be less than 25 years.
5.1.3 The fire and lightning protection requirements of the building curtain wall
shall meet the requirements of GB 50016 and GB 50057.
5.1.4 The toughened glass used for building curtain walls shall meet the
requirements of JG J102. The toughened glass used for doors and windows
shall meet the requirements of GB 15763.4.
5.1.5 For exterior doors and windows with fire resistant integrity requirements,
at least one layer of glass used shall meet the requirements of GB 15763.1. For
the plastic exterior doors and windows, aluminum-plastic composite exterior
doors and windows, steel-plastic co-extruded exterior doors and windows,
aluminum-plastic co-extruded exterior doors and windows profiles, the
reinforced steel or aluminum lining used shall be connected into a closed frame.
Meanwhile, it shall take measures, to prevent the glass from falling off, after
being exposed to fire in the glass inlay slot.
5.1.6 The structural adhesive of glass curtain walls and hidden frame windows
shall meet the requirements of GB 16776.
5.1.7 The selection of building doors and windows shall meet the requirements
of GB/T 30591.
5.2 Performance
5.2.1 Safety
5.2.1.1 Wind load resistance
The wind load resistance of curtain walls, doors and windows is based on the
grading test pressure p3 as the grading index. The grading shall meet the
requirements of Table 2.
Table 2 -- Grading of wind load resistance
5.2.1.2 In-plane deformation performance
The in-plane deformation performance of exterior doors and curtain walls is