|
US$279.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5704-2008: Measuring instruments for anthropometry Status: Valid GB/T 5704: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 5704-2008 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Measuring instruments for anthropometry
| Valid |
GB/T 5704-2008
|
| GB/T 5704.1-1985 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Measuring instruments for anthropometry--Anthropometer
| Obsolete |
GB/T 5704.1-1985
|
PDF similar to GB/T 5704-2008
Basic data | Standard ID | GB/T 5704-2008 (GB/T5704-2008) | | Description (Translated English) | Measuring instruments for anthropometry | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A25 | | Classification of International Standard | 13.180 | | Word Count Estimation | 12,177 | | Date of Issue | 2008-07-16 | | Date of Implementation | 2009-01-01 | | Older Standard (superseded by this standard) | GB/T 5704.1-1985; GB/T 5704.2-1985; GB/T 5704.3-1985; GB/T 5704.4-1985 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2008 (No. 125 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the method used to directly measure the structure of the human body measuring instruments, measuring range, technical requirements, test procedures as well as packaging and marking. This standard applies to the human body altimeter, angle gauge, curved foot gauge, three-legged parallel to the regulation of the design and development. |
GB/T 5704-2008: Measuring instruments for anthropometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Measuring instruments for anthropometry
ICS 13.180
A25
National Standards of People's Republic of China
Replacing GB/T 5704.1 ~ 5704.4-1985
Measuring instruments
Posted 2008-07-16
2009-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is GB/T 5704.1 ~ 5704.4-1985 integration amendments.
5704.1 ~ 5704.4-1985 compared to the main changes in the standards and GB/T as follows.
--- 4 standard part of the original merger, and the structure and format of the standard has been adjusted;
--- Original standard Normative references updated to JJG30-2002 "Universal caliper test procedures";
--- Update certain obsolete references or title appearing in the original standard;
--- Improve the original standard part of the main body altimeter foot lever and foot activities seat;
--- Unified adjust the content of the original standard product packaging and logo.
The standard proposed by China National Institute of Standardization.
This standard by the National Standardization Technical Committee on Human ergonomics.
This standard drafting units. China National Institute of Standardization, Tsinghua University, Beijing Institute of Clothing, assembly equipment FORCE Technology Institute.
The main drafters of this standard. Liutai Jie, Xiao Hui, Li Zhizhong, Zhang Xin, Zheng Rong, Wu San Yu, Hua Ran order.
This standard replaces the standards previously issued as follows.
--- GB/T 5704.1 ~ 5704.4-1985.
Measuring instruments
1 Scope
This standard specifies the method of direct measurement instrument commonly used anthropometric structure, measuring range, technical requirements, test procedures, and packaging and
Mark.
This standard applies to human altimeter, angle gauge, caliper, tripod parallel to the regulation of design and development.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. Where dated references, which subsequently
Some amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Study whether the latest versions of these documents. Anyone who does not dated reference documents, the latest versions apply to this standard.
JJG30-2002 Universal caliper test procedures
3 Structure type
3.1 Human altimeter
3.1.1 Human altimeter by the ruler, fixed foot seat, activity feet seat, curved feet, the main scale rod and the base (see Figure 1).
3.1.2 main foot pole by four interconnected metal tubes (each section length 500mm) and is fixed at the first assembly of the metal tube is fixed to the top of the scale
Seat components. Each end of the metal pipe can fill an appropriately labeled, in order to connect.
3.1.3 fixed scale for the seat is fixedly mounted at the first metal pipe at the top of foot with a total first section metal pipe and fixed foot seat assembly after fixation
A length of 510mm, can be inserted or ruler bent foot fixation foot holder.
3.1.4 activities seat for the foot along the main scale bar for on-foot activities under the seat, can be inserted or ruler bent feet. Activities ruler seat has a foot-shaped frame,
On a rectangular open a small window, a small window on the edge of the foot is inserted in the active seat straightedge ruler or curved lower edge at the same level, on the edge of a small window
(Measured value) position readings measured with a ruler. For ease of reading, on the seat near the fixed end of the scale a small window MARGIN painted red.
3.1.5 The two co-ruler, a ruler inserted If activities within feet seat height can be used to measure various body; If two respectively ruler
Norma and inserted into a fixed scale activities seat, when the first and second metal section of pipe used in conjunction constitute rod straight foot gauge, measure the various human
width.
3.1.6 Total curved foot two, if two feet are inserted into the curved seat fixed foot foot base and activities within, the first and second metal section of the tube when in use,
That is composed of rod caliper, measure the width and thickness of the various human.
3.1.7 the main base for the foot lever to keep the ground perpendicular to the auxiliary member.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5704-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 5704-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5704-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5704-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 5704-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5704-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|