Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 8: Diffusion method
| Valid |
GB/T 5275.8-2014
|
PDF similar to GB/T 5275.8-2014
Basic data | Standard ID | GB/T 5275.8-2014 (GB/T5275.8-2014) | | Description (Translated English) | Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 8: Diffusion method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | G86 | | Classification of International Standard | 71.040.40 | | Word Count Estimation | 18,165 | | Date of Issue | 7/8/2014 | | Date of Implementation | 12/1/2014 | | Quoted Standard | ISO 6145-7 | | Adopted Standard | ISO 6145-8-2005, IDT | | Regulation (derived from) | 2014 National Standards Bulletin No. 18 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the gas mixture prepared by diffusion of the dynamic method. The standard relative expanded uncertainty U, whose value does not exceed �� 2%, the combined standard uncertainty multiplied by a coverage factor (k = 2) obtained. If the |
GB/T 5275.8-2014: Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 8: Diffusion method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 8.. Diffusion method
ICS 71.040.40
G86
National Standards of People's Republic of China
Preparation of gas analysis dynamic volume calibration
Mixed gases - Part 8. Diffusion method
volumetricmethods-Part 8. Diffusionmethod
(ISO 6145-8.2005, IDT)
Issued on. 2014-07-08
2014-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 5275 "gas analysis dynamic volume Preparation of calibration gas mixtures" is divided into the following sections.
--- Part 1. calibration method;
--- Part 2. positive displacement pump;
--- Part 4. continuous injection;
--- Part 5. Capillary calibration devices;
--- Part 6. Critical orifices;
--- Part 7. Thermal mass flow controller;
--- Part 8. Diffusion method;
--- Part 9. Saturation method;
--- Part 10. Permeation;
--- Part 11. Electrochemical method occurs.
This section GB/T 5275 Part 8.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 6145-8.2005 "gas analysis dynamic volume Preparation of calibration gas mixtures 8th
Part I. diffusion method. "
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 5275.7-2014 gas analysis dynamic volume Preparation of calibration gas mixtures - Part 7. Thermal mass flow
Volume controllers (ISO 6145-7.2009, IDT).
This part is proposed by the China Petroleum and Chemical Industry Association.
This part of the National Gas Standardization Technical Committee (SAC/TC206) centralized.
This section drafted by. China Institute of Metrology, Southwest Chemical Industry Research and Design Institute Limited, a Shanghai Song chemical gas
the company.
The main drafters of this section. Zhouze Yi, Chen Yali, Cai Jie.
Preparation of gas analysis dynamic volume calibration
Mixed gases - Part 8. Diffusion method
1 Scope
This section provides diffusion prepared by mole fractions within the range of 10-9 to 10-3 in the calibration gas mixtures dynamic method. The party
Law relative expanded uncertainty U, whose value does not exceed ± 2%, the combined standard uncertainty multiplied by a coverage factor (k = 2) obtained.
If the source line diffusion and use of location between the very short, the diffusion method can be used to prepare a boiling point at room temperature within a range of 40 ℃ ~ 160 ℃ for
Low-Level Calibration liquid organic component gas mixtures.
This section provides the diffusion method, not only for the preparation of the atmospheric environment and indoor air concentrations corresponding to a variety of hydrocarbons calibration mix
Combined gas, a mixed gas of water is also applicable to the preparation of low concentration.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 6145-7 Gas analysis dynamic volume Preparation of calibration gas mixtures - Part 7. Thermal mass flow controllers (Gas
analysis-Preearationofcalibrationgasmixturesusingdynamicvolumetricmethods-Part 7. Thermal
mass-flowcontrolers)
Principle 3
After appropriate calibration component dimensions (length, diameter) of the diffuser diffusion into the gas mixture to be prepared in the carrier gas stream. Container has been charged with
Known high purity liquid calibration component as a component vapor source, mounted vertically on the container the diffuser. The device (cell proliferation) is placed in a constant
Bath temperature, the bath was a known constant flow rate carrier gas purge of high purity (Figure 1). The composition of the mixed gas diffusion by the calibration component
Mass flow and carrier gas flow rate determination.
Diffusion mass flow calibration component depends on the principle.
--- Calibration component in a carrier gas diffusion coefficient;
--- Calibration component vapor pressure at bath temperature;
--- Diffusion tube size.
By diffusion tubes were placed on a magnetic levitation microbalance continuous weighing, or through other periodic weighing microbalance, accurately
Measuring the mass flow rate of diffusion. Determination will affect the calibration component (instantaneous) mass flow uncertainty.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5275.8-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 5275.8-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5275.8-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5275.8-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|