US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 4701.3-2009: Ferrotitanium -- Determination of copper content -- The DDTC photometric method and the flame atomic absorption spectrometric method Status: Valid GB/T 4701.3: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 4701.3-2009 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Ferrotitanium -- Determination of copper content -- The DDTC photometric method and the flame atomic absorption spectrometric method
| Valid |
GB/T 4701.3-2009
|
| GB/T 4701.3-1984 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Methods for chemical analysis of ferrotitanium--The DDTC photometric method for the determination of copper content
| Obsolete |
GB/T 4701.3-1984
|
PDF similar to GB/T 4701.3-2009
Basic data | Standard ID | GB/T 4701.3-2009 (GB/T4701.3-2009) | | Description (Translated English) | Ferrotitanium -- Determination of copper content -- The DDTC photometric method and the flame atomic absorption spectrometric method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | H11 | | Classification of International Standard | 77.100 | | Word Count Estimation | 8,820 | | Date of Issue | 2009-07-08 | | Date of Implementation | 2010-04-01 | | Older Standard (superseded by this standard) | GB/T 4701.3-1984 | | Quoted Standard | GB/T 4010 | | Regulation (derived from) | National Standard Approval Announcement 2009 No.9 (Total No.149) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the determination of copper content of iron in iron copper reagent photometric and flame atomic absorption spectrometry. This section applies to the determination of the steel content in ilmenite. Measuring range (mass fraction): 0. 10% to 1. 00 %. |
GB/T 4701.3-2009: Ferrotitanium -- Determination of copper content -- The DDTC photometric method and the flame atomic absorption spectrometric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Ferrotitanium.Determination of copper content.The DDTC photometric method and the flame atomic absorption spectrometric method
ICS 77.100
H11
National Standards of People's Republic of China
Replacing GB/T 4701.3-1984
Determination of copper content of ilmenite
Copper reagent method and the flame atomic absorption spectrometry
Posted 2009-07-08
2010-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This Part replaces GB/T 4701.3-1984 "Methods for chemical analysis of ferrotitanium copper reagent spectrophotometric determination of copper content."
This portion of the GB/T 4701.3-1984 comparison, the main changes are.
--- Additional flame atomic absorption spectrometry.
This part is proposed by the China Iron and Steel Association.
This part of pig iron and ferroalloy by the National Standardization Technical Committee.
This section is drafted. Sichuan Investment Emei Ferroalloy (Group) Co., Ltd.
The main drafters of this section. should Tang Hua, Fang Yan, Zhang Yingxia.
This part of the standard replaces the previous editions are.
--- GB/T 4701.3-1984.
Determination of copper content of ilmenite
Copper reagent method and the flame atomic absorption spectrometry
Warning --- Use this section shall be a person experiences regular laboratory work. This section does not point out all possible security asked
question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This section specifies the determination of copper content of ilmenite copper reagent method and the flame atomic absorption spectrometry.
This section applies to the determination of copper content in the ilmenite. Measurement range (mass fraction). 0.10% to 1.00%.
2 Normative references
The following documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to this part of the research agreement
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 4010 alloy chemical analysis and preparation of samples
3 a copper reagent spectrophotometric method
3.1 Principle
Sample with nitric acid, hydrofluoric acid dissolved, add citric acid masking iron, titanium and other interfering elements in ammonia solution, add diethyl dithiocarbamate
Sodium (DDTC) with brown colloidal solution form insoluble copper, gum arabic solution was added after the spectrophotometer at a wavelength of 460nm, measured
The amount of its absorbance on the calibration curve have to check the quality of copper, calculated content of copper in the sample.
3.2 Reagents and materials
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or its equivalent purity water.
3.2.1 urea, solid.
3.2.2 hydrofluoric acid, ρ1.15g/mL.
3.2.3 nitrate, 2 + 1.
3.2.4 ammonia, 1 + 1.
3.2.5 boric acid solution, 50g/L.
3.2.6 ammonium citrate solution, 500g/L.
3.2.7 DDTC solution, 2g/L.
3.2.8 gum arabic solution, 10g/L. Weigh 2g gum arabic, dissolved in 100mL of hot water, joined a fine thymol, with removal
After fat cotton filter, diluted with water to 200mL, and mix.
3.2.9 copper standard solution. Weigh 0.5000g copper (Cu≥99.9%), placed in a beaker of 200mL, 30mL of nitric acid was added
(3 + 5), dissolved by heating to boil and removing nitrogen oxides, was cooled to room temperature, transferred to 1000mL volumetric flask, dilute to volume with water, mix
uniform. This solution 1mL copper 500μg.
3.3 Instrument
Analysis using common laboratory instruments.
3.4 Sampling and Preparation
In accordance with the provisions of GB/T 4010 will be sampling and sample preparation, the sample should be adopted 0.125mm sieve.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 4701.3-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 4701.3-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 4701.3-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 4701.3-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 4701.3-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4701.3-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|