US$839.00 ยท In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 44992-2024: Testing equipment for harmonic meters of active energy Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 44992-2024 | English | 839 |
Add to Cart
|
6 days [Need to translate]
|
Testing equipment for harmonic meters of active energy
| Valid |
GB/T 44992-2024
|
PDF similar to GB/T 44992-2024
Basic data | Standard ID | GB/T 44992-2024 (GB/T44992-2024) | | Description (Translated English) | Testing equipment for harmonic meters of active energy | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N29 | | Classification of International Standard | 17.220.20 | | Word Count Estimation | 42,458 | | Date of Issue | 2024-12-31 | | Date of Implementation | 2025-07-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 44992-2024: Testing equipment for harmonic meters of active energy---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 17.220.20
CCSN29
National Standard of the People's Republic of China
Harmonic active energy meter testing device
Released on 2024-12-31
2025-07-01 Implementation
State Administration for Market Regulation
The National Standardization Administration issued
Table of Contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Categories 3
4.1 According to accuracy level 3
4.2 By Phase 3
5 Structure and mechanical properties 3
5.1 Appearance 3
5.2 Wall Meter System 4
5.3 Mechanical protection 4
5.4 Mechanical properties 5
6 Electrical performance 6
6.1 Power supply 6
6.2 Device Output 6
6.3 Error calculation 11
6.4 Output signal monitoring 12
6.5 Insulation 12
6.6 Magnetic Field Generated by the Device 13
6.7 Thermal stability 13
7 Metering performance 14
7.1 Accuracy requirements for working standard tables 14
7.2 Reference conditions 14
7.3 Basic error 15
7.4 Influence 18
7.5 Measurement repeatability 20
7.6 Stability 21
7.7 Multi-channel output consistency 22
7.8 Monitoring system indication error 23
8 Electromagnetic compatibility24
8.1 General requirements 24
8.2 Radio Interference Suppression 24
8.3 Electrostatic discharge immunity 25
8.4 Power frequency magnetic field immunity 25
9 Climate conditions 25
9.1 Normal Climate Conditions 25
9.2 Special climatic conditions 26
10 Inspection Rules 26
10.1 Inspection categories 26
10.2 Factory Inspection 26
10.3 Type inspection 26
11 Packaging, transportation and storage 26
11.1 Packaging 26
11.2 Transportation26
11.3 Storage 26
Appendix A (Informative) Typical Schematic Block Diagram of the Device 28
Appendix B (Normative) Typical waveforms of combined harmonics 29
Appendix C (Normative) Items for factory inspection and type inspection of equipment 36
Reference 37
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents"
Drafting.
Please note that some of the contents of this document may involve patents. The publisher of this document does not assume the responsibility for identifying patents.
This document was proposed by the China Machinery Industry Federation.
This document is under the jurisdiction of the National Technical Committee for Standardization of Electrical Instruments (SAC/TC104).
This document was drafted by. Power Supply Service Management Center of State Grid Jiangxi Electric Power Co., Ltd., Harbin Electric Instrument Research Institute Co., Ltd.,
Zhejiang Hanpu Electric Power Technology Co., Ltd., Shenzhen Xinglong Technology Co., Ltd., Shenzhen Kelu Electronic Technology Co., Ltd., Shanghai
Zhiying Intelligent Technology Co., Ltd., Zhejiang Hengye Electronics Co., Ltd., Guangdong Power Grid Co., Ltd. Measurement Center, Heilongjiang Provincial Electric Power
Instrument and Meter Engineering Technology Research Center Co., Ltd., Ningbo Weiji Electric Power Technology Co., Ltd., Yantai Dongfang Weston Electric Co., Ltd.,
China Electric Power Research Institute Co., Ltd., Shenzhen Longdian Electric Co., Ltd., Delixi Group Instrument Co., Ltd., Yunnan Power Grid Co., Ltd.
Company, Huali Technology Co., Ltd., Ningbo Canaan Intelligent Electric Co., Ltd., Qingdao Qiancheng Technology Co., Ltd., Taiyuan
Youteok Electronic Technology Co., Ltd., State Grid Sichuan Electric Power Company Marketing Service Center, State Grid Sichuan Electric Power Company Guang'an Power Supply Company
Co., Ltd., Yima Electric Energy Measurement Technology (Beijing) Co., Ltd., Guangdong Haoningda Industrial Co., Ltd., Zhengzhou Sanhui Electric Co., Ltd., Guangzhou Nan
Network Research and Technology Co., Ltd., Sichuan University, China Electronics Equipment Shandong Electronics Co., Ltd., Chongqing Huahong Instrument Co., Ltd., Zhejiang Songxia Instrument
State Grid Gansu Electric Power Company Tianshui Power Supply Company, State Grid Anhui Electric Power Company Fuyang Power Supply Company, Anhui Rongzhaozhi
Energy Co., Ltd., Zhejiang Chentai Technology Co., Ltd., and Zhongnan Instrument Co., Ltd.
The main drafters of this document are. Ma Jian, Guo Chuang, Leng Xuedao, Hu Tao, Huang Jianzhong, Cheng Guosheng, Lu Jun, Sun Linzhong, Pan Feng, Wang Huiwu, Wu Weizong,
Wang Jundong, Li Helong, Ma Jian, Yao Guojun, Liu Qingchan, Shen Xin, Chen Wenxin, Zeng Shitu, Zhang Enyou, Chu Fugang, Cao Rui, Li Xiaojun, Meng Yuan,
Guo Yuehang, Liu Lina, He Peidong, Zhou Jun, Yu Wenbiao, Yang Yuyao, Yin Jiayue, Wang Ying, Yu Lingang, Cui Chao, Miao Xing, Feng Shaoyong, Ye Pengcheng, Kang Jian,
Nie Shiguang, Zhang Shaolei, Wang Taofeng, and Lin Keteng.
Harmonic active energy meter testing device
1 Scope
This document specifies the classification, structure and mechanical performance, electrical performance, metering
The quality performance, electromagnetic compatibility, climatic conditions, inspection rules and packaging, transportation and storage requirements are described, and the corresponding test methods are described.
This document applies to newly manufactured harmonic active energy meter testing devices used in laboratory environments.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document.
GB/T 4208-2017 Enclosure protection degree (IP code)
GB 4824-2019 Limits and measurement methods of radio frequency disturbance characteristics of industrial, scientific and medical equipment
GB/T 5169.11-2017 Fire hazard tests for electric and electronic products Part 11.Basic test methods for glowing wire/hot wire
Glow Wire Flammability Test Method for Products (GWEPT)
GB/T 13384-2008 General technical requirements for packaging of electromechanical products
GB/T 16935.1-2023 Insulation coordination for equipment in low-voltage power supply systems Part 1.Principles, requirements and tests
GB/T 17045-2020 General part of electric shock protection devices and equipment
GB/T 17215.211-2021 Electrical measuring equipment (AC) General requirements, tests and test conditions Part 11.Measuring equipment
GB/T 17215.302-2024 Electrical measuring equipment (AC) Particular requirements Part 2.Static harmonic active energy meters
GB/T 17626.2-2018 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test
GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test
3 Terms and definitions
The terms and definitions defined in GB/T 17215.211-2021 and GB/T 17215.302-2024 and the following apply to this document.
3.1
All equipment combinations that provide test signals to the meter under test and measure its fundamental wave active electric energy and harmonic active electric energy measurement errors.
3.2
Working standard meter working standard meter
An instrument used in the device to measure fundamental wave active electric energy and harmonic active electric energy.
3.3
A standard table used to determine the accuracy of a device.
NOTE Reference standards are usually designed and operated in a controlled laboratory environment to achieve high accuracy and stability.
3.4
Harmonic source
The device is used to provide fundamental voltage, harmonic voltage, fundamental current and harmonic current test signals to the working standard meter and the meter under test.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 44992-2024_English be delivered?Answer: Upon your order, we will start to translate GB/T 44992-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 44992-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 44992-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|