HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 43870.2-2024 English PDF

US$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 43870.2-2024: Measurement methods for Curie temperature of magnetic materials - Part 2: Soft magnetic materials
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 43870.2-2024English279 Add to Cart 3 days [Need to translate] Measurement methods for Curie temperature of magnetic materials - Part 2: Soft magnetic materials Valid GB/T 43870.2-2024

PDF similar to GB/T 43870.2-2024


Standard similar to GB/T 43870.2-2024

GB/Z 40842   GB/T 36103.1   SJ/T 10410   GB/T 43795   GB/T 44058   GB/T 43870.1   

Basic data

Standard ID GB/T 43870.2-2024 (GB/T43870.2-2024)
Description (Translated English) Measurement methods for Curie temperature of magnetic materials - Part 2: Soft magnetic materials
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard L19
Classification of International Standard 29.030
Word Count Estimation 14,138
Date of Issue 2024-04-25
Date of Implementation 2024-11-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 43870.2-2024: Measurement methods for Curie temperature of magnetic materials - Part 2: Soft magnetic materials


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29:030 CCSL19 National Standards of People's Republic of China Measuring Method of Curie Temperature of Magnetic Materials Part 2: Soft magnetic materials Released on 2024-04-25 2024-11-01 Implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 How to determine the Curie temperature 1 5 Measurement of Curie temperature 2 5:1 LT Curve Method 2 5:1:1 Measurement principle and method 2 5:1:2 Measuring device 2 5:1:3 Sample 3 5:1:4 Coil 3 5:1:5 Measurement procedure 3 5:1:6 Data Processing 4 5:2 mT Curve Method 4 6 Results Report 4 Appendix A (Informative) Typical Curie Temperature Values of Common Soft Magnetic Materials 5 Figure 1 LT curve and Curie temperature TC diagram 2 Figure 2 Schematic diagram of LT curve method measurement device 3 Table A:1 Typical values of Curie temperature of common soft magnetic materials 5

Foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting: This document is part 2 of GB/T 43870 "Measurement method of Curie temperature of magnetic materials": GB/T 43870 has been published in Lower part: --- Part 1: Permanent magnetic materials; --- Part 2: Soft magnetic materials: Please note that some of the contents of this document may involve patents: The issuing organization of this document does not assume the responsibility for identifying patents: This document was proposed by the Ministry of Industry and Information Technology of the People's Republic of China: This document is under the jurisdiction of the National Technical Committee for Standardization of Magnetic Components and Ferrite Materials (SAC/TC89): This document was drafted by: China University of Metrology, the Ninth Institute of China Electronics Technology Group Corporation, China Institute of Metrology, Zhejiang Province Institute of Metrology, Hengdian Group DMEGC Co:, Ltd:, and Changsha Tianheng Measurement and Control Technology Co:, Ltd: The main drafters of this document are: Ge Hongliang, Wu Qiong, Yan Chong, Peng Qinggui, Gong Wenjie, Yu Zhishu, Zhou Xinhua, Zhang Aiguo, Lei Guoli, Wang Zisheng, Pan Minxiang, Yang Hangfu, and Yu Nengjun:

Introduction

Curie temperature is the transition temperature of the internal magnetic moment of ferromagnetic/ferrimagnetic materials from order to disorder, that is, the transition temperature between ferromagnetism/ferrimagnetism and order: The temperature at which magnetic properties change is one of the basic characteristics of ferromagnetic materials: Curie temperature measurement is part of magnetic property measurement: GB/T 43870 "Measurement method of Curie temperature of magnetic materials" consists of two parts: --- Part 1: Permanent magnetic materials: The purpose is to specify the measurement method of the Curie temperature of permanent magnetic materials: --- Part 2: Soft magnetic materials: The purpose is to specify the measurement method of Curie temperature of soft magnetic materials: Measuring Method of Curie Temperature of Magnetic Materials Part 2: Soft magnetic materials

1 Scope

This document describes a method for the measurement of the Curie temperature of soft magnetic materials: This document is applicable to the measurement of Curie temperature of ferrite soft magnetic materials and metal soft magnetic materials:

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document: For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document: GB/T 2900:60 Electrical terminology - Electromagnetism GB/T 9637 Electrical terminology magnetic materials and components GB/T 28869:1-2012 Measurement methods for cores made of soft magnetic materials Part 1: General specifications GB/T 28869:2-2023 Measurement methods for cores made of soft magnetic materials Part 2: Magnetic properties at low excitation levels GB/T 43870:1 Methods for measuring the Curie temperature of magnetic materials Part 1: Permanent magnetic materials JJF1101-2019 Environmental test equipment temperature and humidity parameter calibration specification

3 Terms and definitions

The terms and definitions defined in GB/T 2900:60 and GB/T 9637 apply to this document:

4 How to determine the Curie temperature

Measure the curve of inductance L changing with temperature T (LT curve) or the curve of magnetic moment m changing with temperature T (mT curve), L- The tangent line at the point where the absolute value of the slope of the T curve or mT curve (dL/dT or dm/dT) is the maximum and L=L0 (L0 is the inductance of the air-core coil) Or m=0 intersects the horizontal axis, and the temperature value here is the Curie temperature, as shown in Figure 1: When the Curie temperature is not higher than 300℃, it is recommended to use the LT curve method; when the Curie temperature is higher than 300℃, it is recommended to use the mT curve method: Line method: The Curie temperature can also be determined in accordance with Chapter 14 of GB/T 28869:2-2023:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 43870.2-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 43870.2-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 43870.2-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 43870.2-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.