US$579.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 42616-2023: Internet of things for lifts, escalators and moving walks - Technical specification of monitoring terminals Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 42616-2023 | English | 579 |
Add to Cart
|
5 days [Need to translate]
|
Internet of things for lifts, escalators and moving walks - Technical specification of monitoring terminals
| Valid |
GB/T 42616-2023
|
PDF similar to GB/T 42616-2023
Basic data | Standard ID | GB/T 42616-2023 (GB/T42616-2023) | | Description (Translated English) | Internet of things for lifts, escalators and moving walks - Technical specification of monitoring terminals | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | Q78 | | Classification of International Standard | 91.140.90 | | Word Count Estimation | 28,274 | | Date of Issue | 2023-05-23 | | Date of Implementation | 2023-12-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 42616-2023: Internet of things for lifts, escalators and moving walks - Technical specification of monitoring terminals ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 91:140:90
CCSQ78
National Standards of People's Republic of China
Elevator Internet of Things Monitoring Terminal Technical Specifications
Released on 2023-05-23
2023-12-01 implementation
State Administration for Market Regulation
Released by the National Standardization Management Committee
table of contents
Preface I
Introduction II
1 Scope 1
2 Normative references 1
3 Terms and Definitions 2
4 Symbols and abbreviations 2
5 Technical requirements 2
6 Test method 9
7 Inspection rules 12
8 Signs, labels and accompanying documents12
9 Packaging, transportation and storage 13
Appendix A (Normative) Equipment faults, events, alarm information and their codes 14
Appendix B (Normative) BACnet Data Communication Protocol for Common Output Ports 17
foreword
This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents"
drafting:
Please note that some contents of this document may refer to patents: The issuing agency of this document assumes no responsibility for identifying patents:
This document is proposed and managed by the National Elevator Standardization Technical Committee (SAC/TC196):
This document is drafted by: Schindler (China) Elevator Co:, Ltd:, Kone Elevator Co:, Ltd:, Shanghai New Star Electric Co:, Ltd:,
Shanghai Special Equipment Supervision and Inspection Technology Research Institute, China Academy of Building Research Co:, Ltd: Construction Mechanization Research Branch, Shanghai Mitsubishi Electric
Elevator Co:, Ltd:, Otis Elevator (China) Investment Co:, Ltd:, Hitachi Elevator (China) Co:, Ltd:, Wuxi Chuanglian Technology Co:, Ltd:, Guangdong
Provincial Special Equipment Testing Research Institute, Chongqing Special Equipment Testing Research Institute, Toshiba Elevator (China) Co:, Ltd:, Guangdong Tiyun Technology Co:, Ltd:
Division, Disheng Elevator (Shanghai) Co:, Ltd:, Otis Electromechanical Elevator Co:, Ltd:, Yongda Elevator Equipment (China) Co:, Ltd:, Hitachi Building Technologies
(Guangzhou) Co:, Ltd:, Suzhou Inovance Technology Co:, Ltd:, Guangzhou Guangri Elevator Industry Co:, Ltd:, CANNY Elevator Co:, Ltd:, Lingwang Electric
Elevator Co:, Ltd:, Xizi Elevator Technology Co:, Ltd:, Hangzhou Theo Elevator Co:, Ltd:, Suzhou Diao Elevator Co:, Ltd:, Xiji Schindler Elevator Co:, Ltd:
Co:, Ltd:, Suzhou Market Supervision and Management Information Center, Dongguan Testing Institute of Guangdong Special Equipment Testing Research Institute, Sunlong Elevator Co:, Ltd:
Company, Giant KONE Elevator Co:, Ltd:, Sicher Elevator Co:, Ltd:, Weber Elevator Co:, Ltd:, Hangzhou Youmai Technology Co:, Ltd:, Disheng
Escalator Co:, Ltd:, Guangdong Huanyu Electronic Technology Co:, Ltd:, Xinti Zhonghe Technology Co:, Ltd:, Beijing Construction Mechanization Research Institute Co:, Ltd:
Company, Guangdong Suzuki Elevator Co:, Ltd:, Ningbo Weike Optoelectronics Co:, Ltd:, Juli Elevator Co:, Ltd:, Ningbo Shenling Electromechanical Technology
limited company:
The main drafters of this document: Wang Mingkai, Bu Lingwei, Du Chao, Jiang Tao, Chen Fengwang, Zhang Liang, Liu Wen, Guo Zhihai, Yan Jing, Lu Feng, Lin Jinjin,
Zhang Jinhao, Han Guoqing, Xie Jun, Zhang Shoulin, Hu Zhaoxia, Tu Changzu, Guo Yaping, Yan Yongwang, Yin Zheng, Kong Canming, Yin Jianfeng, Mao Shibin, Yu Jia,
Tang Linzhong, Zhou Zhenpeng, Chen Liangliang, Zhang Hongliang, Qian Gang, Luo Juping, Shen Jianxue, Yao Yifeng, Cai Zhuofan, Huang Chengjian, Shi Zaihua, Deng Libao, Enwang,
Lin Jingquan, Zhang Zheng, Yuan Huaibing, Huang Wei, Bei Xiaogang:
Introduction
0:1 General
0:1:1 This document does not repeatedly include general technical specifications applicable to any electrical and mechanical:
0:1:2 The monitoring terminal shall be installed and maintained by competent personnel or authorized personnel:
0:2 Assumptions
0:2:1 When formulating this document, the assumptions mentioned in 0:2:2~0:2:4 were made:
0:2:2 This document does not consider that the monitoring terminal cannot work normally due to communication network infrastructure failures, upgrades, routine maintenance, etc:
Case:
0:2:3 The buyer and the supplier have negotiated and reached an agreement on the following contents:
a) the intended use of the monitoring terminal;
b) Environmental conditions, such as exposure to sunlight, wind, snow, corrosive air, explosive gas, combustible dust;
c) ventilation and cooling;
d) Other matters related to the installation site:
0:2:4 The monitoring terminal is well maintained and in normal working condition:
Elevator Internet of Things Monitoring Terminal Technical Specifications
1 Scope
This document specifies the technical requirements, test methods, inspection rules, and standards for monitoring terminals used in the Internet of Things for elevators, escalators and moving walks:
logos, labels and accompanying documents, as well as packaging, transportation and storage:
This document applies to monitoring terminals based on IoT technology for elevators, escalators and moving walks:
This document does not apply to control the operation of elevators, escalators and moving walks through monitoring terminals:
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text: Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document:
GB/T 191 Packaging, storage and transportation icon marks
GB/T 4208-2017 Enclosure protection level (IP code)
GB 4706:1-2005 Safety of Household and Similar Electrical Appliances Part 1: General Requirements
GB/T 5169:16-2017 Fire Hazard Tests for Electrical and Electronic Products Part 16: Test Flame 50W Horizontal and Vertical Fire
Flame test method
GB/T 5226:1-2019 Electrical Safety of Machinery and Electrical Equipment Part 1: General Specifications
GB/T 5465:2-2008 Graphical symbols for electrical equipment Part 2: Graphical symbols
GB/T 7024 Terminology for elevators, escalators and moving walks
GB/T 7588:1-2020 Safety Code for Manufacture and Installation of Elevators Part 1: Passenger Elevators and Freight Elevators
GB/T 9969 General Rules for Instructions for Use of Industrial Products
GB/T 10058-2009 Elevator Technical Conditions
GB/T 13384 General Technical Specifications for Packaging of Mechanical and Electrical Products
GB/T 15127-2008 Twisted pair multipoint interconnection for telecommunication and information exchange between information technology systems
GB/T 15211-2013 Environmental adaptability requirements and test methods for security alarm equipment
GB/T 16895:21 Low-voltage electrical installations Part 4-41: Safety protection against electric shock
GB 16899-2011 Safety regulations for the manufacture and installation of escalators and moving walks
GB 17799:3 General standard for electromagnetic compatibility Emissions in residential, commercial and light industrial environments
GB/T 20645 Technical Requirements for Low-Voltage Electrical Apparatus Used in Plateaus under Special Environmental Conditions
GB/T 24476 Basic Requirements for Elevator Internet of Things Enterprise Application Platform
GB/T 24479-2023 Elevator characteristics under fire conditions
GB/T 24807 Electromagnetic compatibility emission of elevators, escalators and moving walks
GB/T 24808 EMC immunity of elevators, escalators and moving walks
GB/T 26465-2021 Safety Code for Manufacture and Installation of Firefighter Elevators
GB/T 28847:5-2021 Building Automation and Control System Part 5: Data Communication Protocol
GB/T 38632 Information security technology application security requirements for intelligent audio and video collection equipment
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 42616-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 42616-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 42616-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 42616-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|