US$679.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 4056-2019: Dimensions of ball and socket couplings of string insulator units Status: Valid GB/T 4056: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 4056-2019 | English | 679 |
Add to Cart
|
6 days [Need to translate]
|
Dimensions of ball and socket couplings of string insulator units
| Valid |
GB/T 4056-2019
|
GB/T 4056-2008 | English | 999 |
Add to Cart
|
4 days [Need to translate]
|
Ball and socket coupling dimensions of string insulator units
| Obsolete |
GB/T 4056-2008
|
GB/T 4056-1994 | English | RFQ |
ASK
|
6 days [Need to translate]
|
Coupling dimensions of suspension insulators for high voltage lines
| Obsolete |
GB/T 4056-1994
|
GB 4056-1983 | English | 839 |
Add to Cart
|
6 days [Need to translate]
|
Coupling dimensions of suspension insulators for high voltage lines
| Obsolete |
GB 4056-1983
|
PDF similar to GB/T 4056-2019
Basic data Standard ID | GB/T 4056-2019 (GB/T4056-2019) | Description (Translated English) | Dimensions of ball and socket couplings of string insulator units | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K48 | Classification of International Standard | 29.080.10 | Word Count Estimation | 34,328 | Date of Issue | 2019-12-10 | Date of Implementation | 2020-07-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 4056-2019: Dimensions of ball and socket couplings of string insulator units---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Ball and socket connection dimensions for insulator string elements)
ICS 29.080.10
K48
National Standards of People's Republic of China
Replaces GB/T 4056-2008
Ball and socket connection dimensions for insulator string elements
(IEC 60120. 1984, MOD)
2019-12-10 release
2020-07-01 implementation
State Administration of Market Supervision
Published by the National Standardization Management Committee
Contents
Foreword III
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Foot Ball 1
5 Hathole 1
6 Connection Regulations 2
7 Under insulator umbrella 2
8 Locking pin 2
9 Foot ball size 2
10 hat socket size 3
11 Coupling gauge size 4
12 double ball size 6
13 Clearance between foot ball and hat socket 6
14 Effectiveness of locking the ball 7
15 R-pin pin hole size 8
Pin size for 16 W pin 10
Appendix A (Normative) Sliding and tilting positions of the foot in the hat socket
Appendix B (Normative) Gauges 13
References 27
Figure 1 Foot ball size 2
Figure 2 Dimensions of hat socket 3
Figure 3 Dimensions of the connection gauge 4
Figure 4 Schematic diagram of the double ball 6
Figure 5 The gap between the football and the hat socket
Figure 6 The effectiveness of locking the ball 8
Figure 7 Dimensions of pin hole of R-shaped pin 9
Fig. 8 Schematic diagram of pin hole size of W pin
Figure A.1 Schematic diagram of the extreme position of the foot ball in the hat socket 11
Figure A.2 The tilt position of the ball in the hat socket 12
Figure B.1 Schematic diagram of the ball of steel feet 14
Figure B.2 Schematic diagram of the iron cap and socket area 14
Figure B.3 Foot ball height-diameter-length length
Figure B.4 Football ball diameter general rule 16
Figure B.5 Foot ball stop gauge 17
Figure B.6 Foot diameter stop gauge 19
Figure B.7 Foot diameter stop gauge 19
Figure B.8 The entrance height of the hat socket-entrance width-neck width
Figure B.9 Internal height of hat socket-internal diameter diagram
Figure B.10 Schematic diagram of the entrance height stop gauge of the hat socket 24
Figure B.11. Neck width stop gauge of hat socket 25
Table 1 Foot ball main dimensions 2
Table 2 Main dimensions of hat sockets 3
Table 3 Main dimensions of the connection gauge 5
Table 4 Bipod h4 size 6
Table 5 Clearance between the foot ball and the hat socket 7
Table 6 Effectiveness of locking the ball 8
Table 7 Pin hole dimensions for R-type pins 9
Table 8 Pin hole size of W pin 10
Table A.1 Angle deviation of steel feet during sliding 11
Table A.2 Allowable inclination angle of steel foot axis 12
Table B.1. Foot Dimensions-Dimensions-Main Dimensions
Table B.2 Ball diameter rules for feet 16
Table B.3 Ball High Stop Gauge 18
Table B.4. Ball diameter stops for feet 19
Table B.5 Foot diameter stop gauge 20
Table B.6 Entrance Height of Hathole-Entrance Width-Neck Width Passage 20
Table B.7 Internal Height of Hathole-Internal Diameter Gauge 22
Table B.8 Entry height stop gauge for hat socket 24
Table B.9 Neck Width Stop Gauges for Hatholes 26
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 4056-2008 "Ball and socket connection dimensions of insulator string components". This standard is in accordance with GB/T 4056-2008
The main technical changes are as follows.
--- Combining Chapters 1, 2, and 3 of the.2008 edition into Chapter 1 "Scope" (see Chapter 1, Chapters 1 and 2 of the.2008 edition
Chapters 2 and 3).
This standard uses the redrafting method to modify and adopt IEC 60120. 1984 "Ball and socket connection dimensions of insulator string elements".
Compared with IEC 60120. 1984, the structure of this standard has the following changes.
--- Combine Chapters 1, 2 and 3 of IEC 60120. 1984 into Chapter 1 "Scope" (see Chapter 1);
--- Added "normative references" "terms and definitions" (see Chapters 2 and 3).
The technical differences between this standard and IEC 60120. 1984 and their causes are as follows.
--- Regarding the normative reference documents, this standard has made adjustments with technical differences to suit China's technical conditions and the situation of adjustment.
The situation is reflected in Chapter 2 "Regulatory Reference Documents", and the specific adjustments are as follows.
● Replaced IEC 60372..2003 with GB/T 25318-2019 that adopted the international standard (see Chapter 3, Chapter 10,
Chapter 15);
● Added references to GB/T 1001.1-2003, GB/T 2900.8-2009, and GB/T 26874-2011 (see Chapter 3).
--- Table 1 ~ Table 8, Table A.1 ~ Table A.2, Table B.1 ~ Table B.9, added the connection marks 36 and 40 and their size data.
--- The labeling of the connection marks 36 and 40 has been added in FIG. 2.
The following editorial changes have been made to this standard.
--- Increased references.
This standard was proposed by the China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National Insulator Standardization Technical Committee (SAC/TC80).
This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute Co., Ltd., Dalian Power
Porcelain Group Transmission and Transformation Material Co., Ltd., Suzhou Electric Porcelain Factory Co., Ltd., Sichuan Yibin Global Group Co., Ltd., Nanjing Electric
Yuanzi Co., Ltd., General Electric Power Planning and Design Institute, China Southern Power Grid Scientific Research Institute Co., Ltd., China Power Engineering Consulting Group East China Power
Li Design Institute, Sadieville Glass Insulators (Shanghai) Co., Ltd., National Insulator Lightning Arrester Quality Supervision and Inspection Center, NGK Tangshan Electric
Porcelain Co., Ltd., Sinoma Jiangxi Electric Porcelain Electric Co., Ltd., Inner Mongolia Jingcheng High Voltage Insulator Co., Ltd., Zhejiang Tailun Insulator Co., Ltd.
Company, State Grid Zhejiang Power Co., Ltd. Electric Power Research Institute, State Grid Jiangsu Power Co., Ltd. Electric Power Research Institute, State Grid Ningxia
Electric Power Research Institute of Electric Power Co., Ltd., Chongqing University, Changyuan High-Energy Electric Co., Ltd., Guangzhou Maikeling Power Equipment Co., Ltd.,
Pingxiang Best Electric Co., Ltd., Pingxiang Huawei Electric Porcelain Technology Co., Ltd., Xi'an Guanghui Mould Co., Ltd.
With), Sanrui Technology Jiangxi Co., Ltd., Zibo Electric Porcelain Factory Co., Ltd., Xiangyang State Grid Synthetic Insulator Co., Ltd., Zibo Taiguang
Power equipment factory.
The main drafters of this standard. Hu Wenqi, Deng Tao, Wang Yunpeng, Zhang Jijun, Lu Zhou, Zeng Hong, Shi Yubing, Jia Jiangbo, Zhang Fuzeng, Huang Weizhong,
Xiang Liang, Yao Junrui, He Yuanhua, Dong Gang, Yang Ming, Zhang Yaochen, Ji Xiangquan, Zhao Hui, Wang Shaohua, Gao Song, Ye Fengchun, Jiang Xingliang, Fang Bin, Ouyang Xudan,
Liu Jiasheng, Hu Wenhua, Jiao Min, Liu Zhiping, Wang Xingfang, Yang Hongjun, Wei Xia, Wei Peng.
The previous versions of the standards replaced by this standard are.
--- GB/T 4056-1983, GB/T 4056-1994, GB/T 4056-2008.
Ball and socket connection dimensions for insulator string elements
1 Scope
This standard specifies the standard ball and socket coupling series dimensions using standard locking pins (see GB/T 25318-2019), including foot balls and hat sockets
The dimensions of insulator installations and their tolerances are also specified in the inspection gauges required to check these dimensions so that insulators or metal
The pieces are interchangeable.
This standard applies to disc-shaped and long rod-shaped insulator string components with ball and socket connections and their metal accessories.
The size of the ball and cap socket specified in this standard is applicable to the finished product after any surface treatment.
The extreme position of the foot ball in the hat socket is given in Appendix A.
Note. This standard only covers the dimensions necessary for installation, and does not specify material properties and workload. The combination of the connection mark and the strength level is in GB/T 7253-
Provisions in.2019 and GB/T 26874-2011.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 1001.1-2003 Insulators for overhead lines with a nominal voltage higher than 1000V Part 1. Porcelain or glass for AC systems
Insulator component definition, test method and judgment criteria (IEC 60383-1..1993, MOD)
GB/T 2900.8-2009 Insulators for electrical terms (IEC 60050-471..2007, IDT)
GB/T 25318-2019 Lock pin dimensions and tests for ball and socket connection of insulator string components (IEC 60372..2003, MOD)
GB/T 26874-2011 Characteristics of long rod porcelain insulators for high voltage overhead lines (IEC 60433..1998, MOD)
3 terms and definitions
Terms defined in GB/T 1001.1-2003, GB/T 2900.8-2009, GB/T 25318-2019 and GB/T 26874-2011
And definitions apply to this document.
4 foot ball
The main dimensions of the ball shall comply with the provisions of Chapter 9. The main dimensions controlling the shape of the ball are h1, d2, r1 and r2. Exact size r3
Values can only be obtained by plotting and are given for reference only. In addition, the connecting length of the foot bar should be in the range of H3 (see Chapter 11)
Within the range, the diameter of the foot rod d1 should not exceed the specified value.
5 Hatwell
The main dimensions of the cavity of the hat socket and the minimum thickness of the locking pin should be in accordance with Chapter 10.
Note 1. The hat sockets described in this chapter are flat-bottomed. A hat socket with a round bottom with a radius of curvature not less than the ball's size r2 can also be used. In this case, size R5
Will be reduced accordingly.
Note 2. There are two sizes of hat sockets with standard coupling mark 16 in Chapter 10.A and B sizes are the same except for sizes H1, H2 and T
At the same time, there is only one type of steel foot that matches it, and the locking pin used corresponds to that.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 4056-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 4056-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 4056-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 4056-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 4056-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4056-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|