HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 35747-2017 English PDF

US$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 35747-2017: Technical requirements and test methods for air jet room air conditioner
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 35747-2017English199 Add to Cart 3 days [Need to translate] Technical requirements and test methods for air jet room air conditioner Valid GB/T 35747-2017

PDF similar to GB/T 35747-2017


Standard similar to GB/T 35747-2017

GB/T 21551.6   GB/T 39761.1   GB/T 23333   GB/T 21551.4   GB/T 20154   

Basic data

Standard ID GB/T 35747-2017 (GB/T35747-2017)
Description (Translated English) Technical requirements and test methods for air jet room air conditioner
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y61
Classification of International Standard 97.030
Word Count Estimation 10,119
Date of Issue 2017-12-29
Date of Implementation 2018-07-01
Regulation (derived from) National Standards Bulletin 2017 No. 32
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 35747-2017: Technical requirements and test methods for air jet room air conditioner

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical requirements and test methods for air jet room air conditioner ICS 97.030 Y61 National Standards of People's Republic of China Air jet room air conditioner Technical requirements and test methods 2017-12-29 Posted 2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1

4 technical requirements

5 test methods 2 Appendix A (informative) air jet air conditioner model name 3 Appendix B (normative) air supply distance test 4

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard proposed by the China Light Industry Federation. This standard by the National Standardization Technical Committee appliances (SAC/TC46) centralized. This standard was drafted unit. Qingdao Haier Air Conditioner Co., Ltd., China Household Electrical Appliances Research Institute, Guangdong Midea Refrigeration Equipment Co., Ltd., Ningbo Oaks Air Conditioning Co., Ltd., Jiangsu Chunlan Refrigeration Equipment Co., Ltd., Guangdong Chigo Air Conditioning Co., Ltd., the National Freezer refrigerator Preparation of quality inspection center. The main drafters of this standard. Fu Yu, Hu Zhiqiang, Mao Xiangyou, Baiji, Wu Yingqi, Li Baohua, Wang Xianbin. Air jet room air conditioner Technical requirements and test methods

1 Scope

This standard specifies the terms and definitions of air jet room air conditioners (hereinafter referred to as "air conditioners"), technical requirements and tests method. This standard applies to air jet room air conditioners.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 7725-2004 room air conditioners

3 Terms and definitions

GB/T 7725-2004 defined and the following terms and definitions apply to this document. 3.1 Annular air outlet circularairoutletdevice An annular duct body has a through-duct that penetrates through the annular hood body. A wall of the annular-shaped hood body is formed with an air duct communicating with the interior of the air conditioner and a through- Air duct air-conditioning ring opening. 3.2 Air jet airjetflow Based on the fluid ejecting principle, the air around the tuyere is ejected through the annular air ejecting device to increase the air volume and air outlet temperature, Adaptive technology. 3.3 Air jet air conditioner airjetairconditioner Air-jet technology air conditioner products.

4 technical requirements

4.1 General requirements In addition to the requirements of this standard, air conditioners should also meet the requirements of Chapter 5 of GB/T 7725-2004. The type of product should meet the requirements of GB/T 7725-2004 in 4.1, the basic parameters should be consistent with 4.2 of GB/T 7725-2004 Claim. Air jet air conditioner model naming method can be found in Appendix A. 4.2 air jet air flow conditions 4.2.1 Air conditioner rated cooling capacity ≤ 4500W, the air jet state of the measured value of the air flow should not be less than the non-air jet state