US$944.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 35718.2-2017: Power systems management and associated information exchange-interoperability in the long term -- Part 2: End to end quality codes for supervisory control and data acquisition (SCADA) Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 35718.2-2017 | English | 944 |
Add to Cart
|
4 days [Need to translate]
|
Power systems management and associated information exchange-interoperability in the long term -- Part 2: End to end quality codes for supervisory control and data acquisition (SCADA)
| Valid |
GB/T 35718.2-2017
|
PDF similar to GB/T 35718.2-2017
Basic data | Standard ID | GB/T 35718.2-2017 (GB/T35718.2-2017) | | Description (Translated English) | Power systems management and associated information exchange-interoperability in the long term -- Part 2: End to end quality codes for supervisory control and data acquisition (SCADA) | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F21 | | Classification of International Standard | 29.240.01 | | Word Count Estimation | 50,545 | | Date of Issue | 2017-12-29 | | Date of Implementation | 2018-07-01 | | Regulation (derived from) | National Standards Bulletin 2017 No. 32 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 35718.2-2017: Power systems management and associated information exchange-interoperability in the long term -- Part 2: End to end quality codes for supervisory control and data acquisition (SCADA)
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Power systems management and associated information exchange - interoperability in the long term - Part 2. End to end quality codes for supervisory control and data acquisition (SCADA)
ICS 29.240.01
F21
National Standards of People's Republic of China
Power System Management and Information Exchange
Long-term interoperability Part 2. Monitoring and
Data Acquisition (SCADA) end-to-end quality code
Powersystems management and associated information exchange-
interoperabilityinthelongterm-Part 2.Endtoendqualitycodesfor
supervisorycontrolanddataacquisition (SCADA)
(IEC 62361-2.2013, IDT)
2017-12-29 Posted
2018-07-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
Introduction Ⅴ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 applicable IEC standard overview 2
5 substation to the control center quality code flow chart 3
6 existing standard quality code list 4
6.1 The existing standard quality code comparison 4
6.2 IEC 60870-5-101/IEC 60870-5-104 quality code 7
6.2.1 Data related quality 7
6.2.2 Time scale and related quality 7
6.3 IEC 60870-5-103 quality code 8
6.4 IEC 60870-6 (TASE.2) quality code 8
6.4.1 Data related quality 8
6.4.2 Time stamping and related quality 9
6.5 IEC 61850 quality code (from IEC 61850-7-3) 10
6.5.1 Data related quality 10
6.5.2 Quality in the Client Server Environment 13
6.5.3 Quality Identification of the relationship between 13
6.5.4 Time stamp and related quality 15
6.6 IEC 61970-301 quality code 16
6.6.1 Overview 16
6.6.2 MeasurementValueQuality attribute as defined in IEC 61970-301
6.6.3 MeasurementValueSoure naming conventions 17
6.7 OPC and OMG Quality Code 18
6.7.1 OPCDA quality code 18
6.7.2 DAIS Data Access Quality Code 20
6.7.3 Time stamps and related qualities 25
6.8 OPCUA Data Access Status Code (DataAccessStatusCodes) 25
6.8.1 Overview 25
6.8.2 Operation level result code 25
7 quality code mapping between different standards 26
7.1 Overview
7.2 Mapping from IEC 61850 to IEC 60870-5-101/IEC 60870-5-104 27
7.3 Mapping from IEC 60870-5-101/IEC 60870-5-104 to IEC 61970-301
7.4 Mapping from IEC 61850 to IEC 61970-301
7.5 Mapping from IEC 60870-6 (TASE.2) to IEC 61970-301
7.6 Mapping from IEC 61970-301 to IEC 60870-6 (TASE.2) 33
7.7 Mapping from IEC 61850 to DAISDA and OPCDA 35
Common quality code across power system information exchange standards
8.1 Public Quality Code 38
8.2 Quality Code Definition 38
8.2.1 Validity code 38
8.2.2 Detailed Quality Code 39
8.2.3 Additional Quality Code 42
8.2.4 Time-related quality code 42
8.2.5 source code 43
Foreword
This section GB/T 35718 "power system management and long-term exchange of information interoperability," the second part.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with the International Electrotechnical Commission IEC 62361-2.2013 "power system management and information exchange long-term
Interoperability Part 2. Monitoring and Data Acquisition (SCADA) End-to-End Quality Codes. "
The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.
--- GB/T 18700 (all parts) Telecontrol equipment and systems Part 6. Compatibility with ISO standards and ITU-T recommendations
Moving Agreement [IEC 60870-6 (TASE.2) (alparts)]
--- IEC 60870-5 (all parts) IEC 60870-5-1,2,3,4,5,101,102,103,104 and other parts, have been the same mining
Used as China's national standard or power industry standards.
● GB/T 18657.1-2002 Telecontrol equipment and systems Part 5. Transmission protocol Part 1. Transmission frame format
(IEC 60870-5-1.1990.IDT)
● GB/T 18657.2-2002 Telecontrol equipment and systems Part 5. Transmission protocol Part 2. Link transmission rules
(IEC 60870-5-2.1992.IDT)
● GB/T 18657.3-2002 Telecontrol equipment and systems Part 5. Transmission protocol Part 3. Application data general
Structure (IEC 60870-5-3.1992.IDT)
● GB/T 18657.4-2002 Telecontrol equipment and systems Part 5. Transmission protocol Part 4. Application information element set
Meaning and coding (IEC 60870-5-4.1992.IDT)
● GB/T 18657.5-2002 Telecontrol equipment and systems Part 5. Transmission Protocol Part 5. Basic application functions
(IEC 60870-5-5.1995.IDT)
● DL/T 634.5101-2002 Telecontrol equipment and systems Part 5101 Transmission protocols Basic telematics tasks
(IEC 60870-5-101.2002, IDT)
● DL/T 634.5104-2009 Telecontrol equipment and systems Section 5-104. Transmission protocols using the standard transmission protocol
IEC 60870-5-101 Network Access for Subsets (IEC 60870-5-104.2006, IDT)
● DL/T 667-1999 Telecontrol equipment and systems Part 5. Transmission protocol Part 103. Relay protection equipment information
Interface (IEC 60870-5-103.1997, IDT)
● DL/T 719-2000 Telecontrol equipment and systems Part 5. Transmission protocol Chapter 102. Power System Power Accumulation
Transmission (IEC 60870-5-102.1996, IDT)
--- DL/T 860 (All Parts) Power Automation Communication Networks and Systems [IEC 61850 (alparts)]
--- DL/T 860.3-2004 Substation communication networks and systems - Part 3. General requirements (IEC 61850-3.2002, IDT)
--- DL/T 860.72-2013 Power Automation Communication Networks and Systems - Part 7-2. Basic Communication Architecture - Abstract Communication Services
Service Interface (ACSI) (IEC 61850-7-2.2010, IDT)
--- DL/T 860.73-2013 Power Automation Communication Networks and Systems - Part 7-3. Basic Communication Architecture - Public Data Classes
(IEC 61850-7-3.2010, IDT)
--- DL/T 890 (all parts) Energy Management System Application Program Interface (EMS-API) [IEC 61970 (alparts)]
--- DL/T 890.301-2016 Energy management system application program interface (EMS-API) Part 301. Common Information Model
(CIM) Foundation (IEC 61970-301.2013, IDT)
Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents.
This part is proposed by China Electricity Council.
This part of the National Power System Management and Information Exchange Standardization Technical Committee (SAC/TC82) centralized.
This part of the drafting unit. NARI Group Company (State Grid Electric Power Research Institute), State Power NARI Technology Co., Ltd., Nanjing NARI
Paul Electric Co., Ltd., China Electric Power Research Institute, State Grid Jiangsu Electric Power Company Electric Power Research Institute, the State Power Dispatching Control Center,
China Southern Power Grid Co., Ltd. System Operation Department (Power Dispatching Control Center), State Grid Jilin Power Co., Ltd., Xu Ji Electric shares
Limited.
The main drafters of this section. Zhou Bin, Li Jinsong, Shen Jian, Huang Jian, Tuk Chun, Chen Lili, Yuan Yu Bo, Chen Dehui, Shi Yuxiang, Yang Zhihong, Wang Yongfu,
Yang Wei, Li Jin, Zhang Jiguo, Liao Zeyou, Zhang Bin, Wang Haifeng.
Introduction
The scope of this section is to establish a common SCADA quality code list for reference to other standards to avoid embedding in other standards
Quality code list.
Power System Management and Information Exchange
Long-term interoperability Part 2. Monitoring and
Data Acquisition (SCADA) end-to-end quality code
1 Scope
GB/T 35718 of this section will be applied to the power system management and monitoring and data acquisition (SCADA) related to the existing
IEC standard quality code collection written. This version of this section does not consider the quality of meter readings. It's ok and brought together
The mapping between standards also documents the eventual loss of quality information that may have occurred in the mapping, defines a closely related,
Public, semantic quality code list. This part of the research and processing standards are. IEC 60870-5, IEC 60870-6TASE.2,
IEC 61850, IEC 61970, DAISDA, OPCDA and OPCUA.
The data covered in this section is the measurement data provided by the following links, applications, interfaces.
● RTU, IEC 61850 or OPCDA to SCADA link;
Verification of increased state estimation;
● TASE.2 (ICCP) or TASE.1 (ELCOM) link between control centers;
● A server that provides OPC or DAISDA-data, such as SCADA.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 60870-5 (all parts) Telecontrol equipment and systems Part 5. Transmission protocol (Telecontrolequipmentandsys-
tems-Part 5.Transmissionprotocols)
IEC 60870-6 (All parts) Telecontrol equipment and systems - Part 6. Telecontrol equipment compatible with ISO standards and ITU-T recommendations
Telecontrolequipmentandsystems-Part 6.Telecontrolprotocolscompatiblewith ISO standards
andITU-Trecommendations)
IEC 61850 (all parts) Electric power automation communication networks and systems (Communicationnetworksandsystemsfor
powerutilityautomation)
IEC 61850-3 Electric power automation communication networks and systems - Part 3. General requirements (Communicationnetworksand
systemsforpowerutilityautomation-Part 3.Generalrequirements)
IEC 61850-7-2.2010 Electric power automation communication networks and systems - Part 7-2 - Basic communication architecture - Abstract communication services
Mouth (ACSI) [Communicationnetworksandsystemsforpowerutilityautomation-Part 7-2.Basiccom-
municationstructure-Abstractcommunicationserviceinterface (ACSI)]
IEC 61850-7-3 Electric power automation communication networks and systems - Part 7-3 - Basic communication structure - Commu-
nicationnetworksandsystemsforpowerutilityautomation-Part 7-3.Basiccommunicationstruc-
ture-Commondataclasses)
IEC 61970 (all parts) Energy Management System Application Program Interface (EMS-API) [Energymanagementsystemap-
plicationprograminterface (EMS-API)]
IEC 61970-301 Energy management system application program interface (EMS-API) part 301. Public Information Model (CIM) Fundamentals
[Energymanagementsystemapplicationprograminterface (EMS-API) -Part 301.Commoninforma-
tionmodel (CIM) base]
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 35718.2-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 35718.2-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 35718.2-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35718.2-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|