US$999.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 35711-2017: Analysis, restrain and measurement of harmonics of DC side of high voltage direct current (HVDC) transmission system Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 35711-2017 | English | 999 |
Add to Cart
|
7 days [Need to translate]
|
Analysis, restrain and measurement of harmonics of DC side of high voltage direct current (HVDC) transmission system
| Valid |
GB/T 35711-2017
|
PDF similar to GB/T 35711-2017
Basic data | Standard ID | GB/T 35711-2017 (GB/T35711-2017) | | Description (Translated English) | Analysis, restrain and measurement of harmonics of DC side of high voltage direct current (HVDC) transmission system | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F21 | | Classification of International Standard | 29.240.01 | | Word Count Estimation | 50,583 | | Date of Issue | 2017-12-29 | | Date of Implementation | 2018-07-01 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 35711-2017: Analysis, restrain and measurement of harmonics of DC side of high voltage direct current (HVDC) transmission system ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Analysis, restrain and measurement of harmonics of DC side of high voltage direct current (HVDC) transimission system
ICS 29.240.01
F21
National Standards of People's Republic of China
HVDC DC system harmonic analysis,
Suppression and measurement guidelines
Analysis, restrainandmeasurementofharmonicsofDCsideofhighvoltage
directcurrent (HVDC) transimissionsystem
(IEEE Std 1124..2003, GuideforanalysisanddefinitionofDCside
harmonicperformanceofHVDCtransmissionsystems, MOD)
2017-12-29 Posted
2018-07-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 research methods 4
5 DC Harmonic Analysis 7
6 Induced noise analysis 20
7 interference suppression measures 32
8 DC Filter Performance Specifications 34
HVDC filter performance measurement
Appendix A (Informative) Common-mode transimpedance and differential mode transimpedance calculation example 41
Appendix B (informative) Example calculation of transmission line impact area 42
Appendix C (informative) Examples of anti-jamming filter modification and communication line transformation example 43
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses redrafted law revision IEEEStd1124..2003 "HVDC transmission system harmonic analysis of the DC side
And definition. " The main technical differences compared to IEEEStd1124..2003 are as follows.
--- Modify the DC filter system research flow (see 4.1), the pre-feasibility study stage, feasibility study stage, contact coordination stage research
Research unity for the design phase, in line with our general engineering design process;
--- Modify the weighting curve used to measure noise effect (see Figure 1) and noise measurement method (see 9.2) to make it comply with China's noise test
The amount of engineering practice.
This standard made the following editorial changes.
--- The standard name was changed to "HVDC HVDC harmonic analysis, suppression and measurement guidelines."
This standard proposed by the China Electricity Council.
This standard by the National HVDC Project Standardization Technical Committee (SAC/TC324) centralized.
This standard was drafted. State Grid Beijing Institute of Economic and Technology.
The main drafters of this standard. Ji Yiming, Ma Weimin, Yang Yiming, Zhang Tao, Wu Fangtao, Xue Yinglin, Li Xuan, Liu Xintao, Wu Yankun, Zhao Zheng.
HVDC DC system harmonic analysis,
Suppression and measurement guidelines
1 Scope
This standard specifies the LCC DC HVDC converter station DC-side harmonic analysis, suppression and measurement of recommended methods, including
Norms related to the guidelines, but also provides a recommended DC filter performance measurement methods and DC transmission line harmonic current sense in the communication line
The recommended method of calculating the noise level that should be generated.
This standard applies to DC transmission system converter station generated harmonic frequency below 5kHz electromagnetic noise.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 13498 HVDC terms
DC Filter Capacitor and Neutral Bus Impact Capacitor for GB/T 20993 HVDC Transmission System
GB/T 25308 HVDC transmission system DC filter
3 Terms and definitions
GB/T 13498, GB/T 20993, GB/T 25308 as defined by the following terms and definitions apply to this document.
3.1
DC Harmonic DCharmonics
HVDC system DC voltage or current in the AC harmonic components. For an ideal bridge converter, the DC voltage is harmonic
Frequency is only an even multiple of the fundamental frequency of the fundamental frequency; however, in practice due to system imbalance and stray capacitance,
The remaining even and odd multiples of frequency (non-feature frequency).
3.2
Ideal converter idealconverter
Equivalent for the purpose of a balanced sinusoidal voltage, circuit impedance, firing angle, no stray capacitance, DC current smooth inverter.
3.3
Harmonic order harmonicorder
DC voltage/current of a harmonic component of its own frequency and AC side of the converter frequency ratio.
3.4
Characteristic/noncharacteristicharmonics
In ideal converters, based on the theoretical waveform of the converter DC voltage, harmonics can be expressed in terms of the number of ripple of the converter,
Dynamic converter, the number of characteristic harmonics can be described as 6m times, where m is an integer. In general, the characteristic harmonics can be used pm times
Description, where p is the number of pulses. The rest of the harmonics that do not meet the above characteristics are non-characteristic harmonics. Non-characteristic harmonics are generally smaller.
3.5
Triple harmonic triplenharmonics
The third harmonics of the third harmonic, such as 3,6,9,12,15, can be classified as odd or even times. Even third harmonic harmonic is
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 35711-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 35711-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 35711-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35711-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|