US$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 35141-2017: Specifications for insertion type infrared radiation thermometer Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 35141-2017 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Specifications for insertion type infrared radiation thermometer
| Valid |
GB/T 35141-2017
|
PDF similar to GB/T 35141-2017
Basic data | Standard ID | GB/T 35141-2017 (GB/T35141-2017) | | Description (Translated English) | Specifications for insertion type infrared radiation thermometer | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N11 | | Classification of International Standard | 17.200.20; 25.040.40 | | Word Count Estimation | 14,139 | | Date of Issue | 2017-12-29 | | Date of Implementation | 2018-07-01 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 35141-2017: Specifications for insertion type infrared radiation thermometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specifications for insertion type infrared radiation thermometer
ICS 17.200.20; 25.040.40
N11
National Standards of People's Republic of China
Insertion infrared radiation thermometer technical specifications
2017-12-29 Posted
2018-07-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 principles and structure 1
5 product classification and basic parameters 2
5.1 Product Category 2
5.2 Basic parameters 2
6 Technical Requirements 3
6.1 Assembly quality and appearance 3
6.2 Basic error 3
6.3 Stability 4
6.4 Safety Performance 4
6.5 Impact test 4
6.6 anti-transport environmental performance 5
7 test equipment 5
7.1 standard device 5
7.2 standard equipment 5
7.3 Other equipment 5
7.4 source 6
8 Test Method 6
8.1 Test conditions 6
8.2 Assembly Quality and Appearance 6
8.3 Performance Test 6
8.4 Safety Performance 7
8.5 Impact of the amount of influence 7
8.6 anti-transport environmental performance 7
Inspection rules 8
9.1 General 8
9.2 factory inspection 8
9.3 type test 8
10 logo, packaging, transportation and storage 9
10.1 logo 9
10.2 Packaging 9
10.3 Transportation 9
10.4 Storage 9
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by the China Machinery Industry Federation.
This standard by the National Institute of Industrial Process Control and Automation Standardization Technical Committee (SAC/TC124) centralized.
This standard drafting unit. Hebei Institute of Metrology, China Aerospace Aerodynamics Research Institute, Measurement and Supervision Institute of Hebei Province,
Tianjin Institute of Metrology and Supervision, Shanghai Institute of Industrial Automation Instruments.
The main drafters of this standard. Kang Zhiru, Guo Qiang, Cai Jiewei, Chen Su, Liu Hongyan, Li Jie, Xiao Hong Lian, Tian Yun, Chen Hao, Liu Min.
Introduction
Plug-in infrared radiation thermometer is a combination of contact temperature and radiation temperature measurement of two characteristics of temperature measurement instruments, it also has a radiation test
The amount of measurable high temperature and contact temperature measurement accuracy advantages, and the price is low, easy to use, are widely used in metallurgy, metallurgy and other industries have produced
Process temperature measurement and control.
Because there is no uniform national standards, the manufacturers according to their own business standards for production, making the product quality is uneven, in use
The accuracy of temperature measurement can not be guaranteed.
This standard unifies the technical parameters, expression of error formula, test methods, data processing, etc., on the accuracy of the instrument temperature was higher
Requirements, can regulate the production of instruments, play a catalytic role in the development of the industry.
Insertion infrared radiation thermometer technical specifications
1 Scope
This standard specifies the terms and definitions, principles and structure of the insert infrared radiation thermometer (hereinafter referred to as "thermometer"), product classification and
Basic parameters, technical requirements, test equipment and test methods, inspection rules, marking, packaging, shipping and storage requirements.
This standard applies to the temperature range of 800 ℃ ~ 1600 ℃, with corundum tube temperature probe, connect the photoelectric converter and display instrument output
Thermometer temperature value.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
General technical requirements for packaging of electromechanical products
GB/T 18271.3-2000 Process measurement and control devices - General performance evaluation methods and procedures - Part 3. Impact of influence
Test
Industrial automation instruments terminology temperature instruments
Instrumentation transport, storage of the basic environmental conditions and test methods
Common measurement terms and definitions
3 Terms and definitions
GB/T 25475-2010 and JJF1001-2011 defined by the following terms and definitions apply to this document.
3.1
Infrared radiation thermometer infraredradiationthermometer
The use of thermal radiation body in the infrared band flux to measure the temperature of the instrument.
3.2
Photoelectric converter photoelectrictransducer
A device that converts an optical signal into an electrical signal.
4 principles and structure
Thermometer from corundum tube, photoelectric converter and display instrument. In the measurement of temperature, the corundum tube is inserted into the measured medium, corundum
Tube measuring terminal and the measured medium to achieve thermal equilibrium, the photoelectric converter will convert the brightness temperature DC voltage signal, the display instrument shows the temperature
value. Thermometer structure diagram shown in Figure 1.
Figure 1 thermometer structure diagram
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 35141-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 35141-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 35141-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35141-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|