GB/T 34035-2017: Field test methods for thermocouples
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34035-2017English199 Add to Cart 3 days [Need to translate] Field test methods for thermocouples Valid GB/T 34035-2017

PDF similar to GB/T 34035-2017


Standard similar to GB/T 34035-2017

GB/T 20730.2   GB/T 19146   GB/T 22065   GB/T 45358   GB/T 34037   

Basic data

Standard ID GB/T 34035-2017 (GB/T34035-2017)
Description (Translated English) Field test methods for thermocouples
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N11
Classification of International Standard 17.200.20
Word Count Estimation 10,197
Date of Issue 2017-07-31
Date of Implementation 2018-02-01
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 34035-2017: Field test methods for thermocouples

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Field test methods for thermocouples ICS 17.200.20 N11 National Standards of People's Republic of China Thermocouple field test methods 2017-07-31 Posted 2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the China Machinery Industry Federation. This standard by the National Institute of Industrial Process Control and Automation Standardization Technical Committee (SAC/TC124) centralized. The main drafting units of this standard. Shanghai Industrial Automation Instrumentation Research Institute Co., Ltd.. Participated in the drafting of this standard. Anhui Tiankang Co., Ltd., Chongqing Dazheng temperature instrument company, Chongqing Sichuan Instrument Factory Co., Ltd. 17, National Nuclear Instrument System Engineering Co., Ltd., Measurement and Supervision Institute of Hebei Province, Shanghai Automation Instrumentation Co., Ltd., Shanghai Measurement Test Technology Research Institute, China Institute of Metrology, Zhejiang Rant Electrical Co., Ltd., China National Accreditation Center for Conformity Assessment. The main drafters of this standard. Xiaohong Lian, Fan Kai, Chen Di, Zhou Buyu, Zhou Hongqin, Kang Wenjie, Li Shusheng, Guo Qiang, Wan Guoliang, Zheng Wei, Zheng Wei, Xu Yunsheng.

Introduction

Thermocouples are widely used in industry and have high reliability when used within their specified temperature range. However, if in use out Now failure, the consequences can be light and heavy, and even threaten personal safety. In general, this may result in significant loss of equipment, product, or uptime. use The user should weigh the potential consequences of a thermocouple failure to determine which tests to make before and after thermocouple installation and during use. This standard is intended for the thermocouple, thermocouple machine and the connecting wire guide to provide field testing to avoid the thermocouple in the storage, installation or Damage during use, not as a guide to acceptance testing. The test method covers basic tests to ensure correct installation of the thermocouple, as well as some simple tests necessary for failure analysis. and Uniformity, capacitance and loop current step response thermocouple test, due to the need to be equipped with complex equipment and for complex analysis, in this standard No rules. Normally produced thermocouple malfunctions, usually due to incorrect installation and operation outside the specified limits during use. These ones Most of the most common forms of fault conditions can be detected by using the test methods given in this standard. When the thermocouple machine for the first time installed in the working environment should be the provisions of this standard test. However, these tests do not guarantee the thermocouple Function to accurately display the temperature. To ensure accuracy, the need to select the appropriate thermocouple and instrumentation, as well as measuring the temperature to select the appropriate test Points. Thermocouple field test methods

1 Scope

This standard specifies the method of testing the thermocouple machine, including the compensation wire, before and after installation, or after a period of use. The purpose of the test is to ensure that the thermocouple machine is not damaged during storage or installation, compensating for the positive polarity of the connection between the conductor and the terminal Indeed, and for the future test evaluation thermocouple machine is damaged after use to provide reference data. Some of these tests may not apply to highs Specific types of thermocouples operating at the recommended limits of temperature. This standard specifies the test, including the installation of thermocouple after measuring the following variables, and to determine whether the thermocouple machine is working In the damage to provide reference data. --- Loop resistance. ● hot electrode; ● Compensation wire and thermode. --- Insulation resistance. ● thermocouple machine insulation; ● thermocouple machine and compensation wire insulation. --- Thermoelectric power. ● hot electrode; ● Compensation wire and thermocouple machine.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. Compensating lead for thermocouple GB/T 4989-2013 Industrial automation instruments terminology temperature instruments Industrial thermocouples

3 Terms and definitions

GB/T 25475-2010 defined and the following terms and definitions apply to this document. 3.1 Junction type junctionclass Electrical continuity of the terminals of the thermocouple. For example, insulation type, grounding type and so on. Insulated - Thermocouple Measurement terminals without electrical contact with the conductive protective sleeve or circuit reference ground. Grounding type - Thermocouple Measurement end in direct electrical contact with a protective sleeve or box. [GB/T 25475-2010, definitions 2.5.60, 2.5.62 and 2.5.63] 3.2 Detection circuit sensingcircuit The sum of the thermode and compensation leads, but excluding signal conditioning components such as reference junction compensators, amplifiers, transmitters, and more.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 34035-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 34035-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 34035-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 34035-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.