   US$219.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32793-2016: Methods for chemical analysis of nickel sinter and nickel oxide -- Determination of nickel, cobalt, copper, iron, zinc, manganese contents -- Electrolytic gravimetric method and Inductively coupled plasma atomic emission spectrometric method Status: Valid    
      
    
  
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF | 
		 
			| GB/T 32793-2016 | English | 219 | 
   Add to Cart
   | 
                    3 days [Need to translate]
                 | 
                    Methods for chemical analysis of nickel sinter and nickel oxide -- Determination of nickel, cobalt, copper, iron, zinc, manganese contents -- Electrolytic gravimetric method and Inductively coupled plasma atomic emission spectrometric method
                 | Valid | 
                    GB/T 32793-2016
                 | 
		 
	 
     
     
  
	 
       PDF similar to GB/T 32793-2016 
    
   
    
     
          
  
  
    
  Basic data             |  Standard ID  |          GB/T 32793-2016 (GB/T32793-2016) |               |  Description (Translated English)  |          Methods for chemical analysis of nickel sinter and nickel oxide -- Determination of nickel, cobalt, copper, iron, zinc, manganese contents -- Electrolytic gravimetric method and Inductively coupled plasma atomic emission spectrometric method |               |  Sector / Industry  |          National Standard (Recommended) |               |  Classification of Chinese Standard  |          H13 |               |  Classification of International Standard  |          77.120.40 |               |  Word Count Estimation  |          11,195 |               |  Date of Issue  |          2016-08-29 |               |  Date of Implementation  |          2017-07-01 |               |  Regulation (derived from)  |          National Standard Announcement 2016 No.14 |               |  Issuing agency(ies)  |          General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |         
  GB/T 32793-2016: Methods for chemical analysis of nickel sinter and nickel oxide -- Determination of nickel, cobalt, copper, iron, zinc, manganese contents -- Electrolytic gravimetric method and Inductively coupled plasma atomic emission spectrometric method
  ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.  
Methods for chemical analysis of nickel sinter and nickel oxide - Determination of nickel, cobalt, copper, iron, zinc, manganese contents - Electrolytic gravimetric method and Inductively coupled plasma atomic emission spectrometric method
ICS 77.120.40
H13
National Standards of People's Republic of China
Methods for chemical analysis of sintered nickel and nickel oxide
Determination of Nickel, Cobalt, Copper, Iron, Zinc and Manganese
Electrolytic gravimetric method - inductively coupled plasma atom
Emission spectroscopy
Determinationofnickel, cobalt, copper, iron, zinc, manganesecontents-
2016-08-29 release.2017-07-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by China Nonferrous Metals Industry Association.
This standard is owned by the National Committee for the Standardization of Nonferrous Metals (SAC/TC243).
This standard is responsible for drafting unit. Shanxi TISCO Stainless Steel Co., Ltd.
This standard participates in the drafting unit. Beijing Institute of Mining and Metallurgy, Guangzhou Nonferrous Metals Research Institute, Steel Research and Technology Co., Ltd., Jinchuan
Group Co., Ltd., Tianjin Mao of the Technology Co., Ltd.
The main drafters of this standard. Dai Xueqian, Zhang Ruilin, Hu Jianchun, Liu Chunfeng, Su Chunfeng, Chen Xiaodong, Li Jie, Zou Jiying, Qi Shiqing, Qiu Ping,
Lin Xiuying.
Methods for chemical analysis of sintered nickel and nickel oxide
Determination of Nickel, Cobalt, Copper, Iron, Zinc and Manganese
Electrolytic gravimetric method - inductively coupled plasma atom
Emission spectroscopy
WARNING - Personnel using this standard should have practical experience in formal laboratory work. This standard does not indicate all possible security questions
question. It is the responsibility of the user to take appropriate safety and health measures and to ensure compliance with the conditions set forth in the relevant national regulations.
1 Scope
This standard specifies the determination of nickel content in sintered nickel and nickel oxide by electrolytic gravimetric method, and is measured by inductively coupled plasma atomic emission spectrometry
Determination of cobalt, iron, iron, zinc and manganese content.
This standard applies to the analysis of nickel, cobalt, copper, iron, zinc and manganese content in sintered nickel, nickel oxide and partially reduced nickel oxide. Determination of each element
The range is shown in Table 1.
Table 1 Determination of each element
Elemental determination range (mass fraction) /%
Ni 74 ~ 96
Co 0.02 to 1.5
Cu 0.005 to 0.2
Fe 0.02 to 1.5
Zn 0.001 to 0.3
Mn 0.008 to 1.5
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 4010 Ferroalloy chemical analysis of the sample to take and preparation
3 method summary
Samples by nitric acid and perchloric acid decomposition, in the ammonia medium, with constant current electrolysis, then nickel deposition to the platinum cathode. After electrolysis is terminated,
The platinum cathode was washed with water and absolute ethanol, dried and weighed and cooled. Platinum on the cathode of cobalt, copper, iron, zinc, manganese and other impurities, electrolytic residue and
The residual nickel, cobalt, copper, iron, zinc and manganese contents in the filter residue were measured by inductively coupled plasma atomic emission spectrometry. Finally, calculate the calculation
The total amount of nickel in the sample, and the cobalt, copper, iron, zinc and manganese contents in the sample.
   
   
  
  
    
  Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32793-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32793-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 32793-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32793-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):  List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to  [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.  
        
   
        
       
          
               
 
          |