GB/T 32211-2015: Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 32211-2015English279 Add to Cart 3 days [Need to translate] Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography Valid GB/T 32211-2015

PDF similar to GB/T 32211-2015


Standard similar to GB/T 32211-2015

GB/T 40219   JJG 2060   GB/T 30431   GB/T 32206   GB/T 32205   

Basic data

Standard ID GB/T 32211-2015 (GB/T32211-2015)
Description (Translated English) Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N52
Classification of International Standard 17.180.99
Word Count Estimation 13,149
Date of Issue 2015-12-10
Date of Implementation 2016-07-01
Quoted Standard ASTM E 275; ASTM E 682
Regulation (derived from) National Standard Announcement 2015 No.38
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard applies to variable-wavelength photometric detector (VWPD) performance tests, the detector is a liquid chromatography system or component detecting multiple wavelengths operating within 190 nm ~ 800 nm wavelength range. 32212-2015 is consistent with GB /T, generally use test wavelength 254 nm, other wavelengths can also choose to be tested. This standard is intended to describe the performance of the detector, including independent of the chromatographic system static performance and dynamic performance of the mobile phase through.

GB/T 32211-2015: Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography ICS 17.180.99 N52 National Standards of People's Republic of China Liquid chromatography using a variable-wavelength photometric Test Method detector Issued on. 2015-12-10 2016-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Machinery Industry Federation. This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized. This standard was drafted. China Instrument Industry Association, Dalian Elite Analytical Instruments Co., Ltd., China Institute of Metrology, Innovation Technology Co., Ltd. Beijing Heng Tong, East China University of Technology, Beijing Institute of analysis instruments. The main drafters of this standard. Maya Juan, Zhang Xueyun, Tao Hong, Shen Zhigang, Zhang Bing, Louxing Jun. Liquid chromatography using a variable-wavelength photometric Test Method detector

1 Scope

This standard is used to guide the variable-wavelength photometric detector (VWPD) performance tests, the detector is in a liquid chromatography system 190nm ~ detecting means of one or more wavelengths within the working range of the wavelength of 800nm. Of the GB/T 32212-2015 consistent, generally Use test wavelength 254nm, you can also choose other wavelengths for testing. This standard is intended to describe the performance of the detector, including independent of the chromatographic system static performance and dynamic performance of the mobile phase through. About LC program general description, see reference [1] to [9]. Rationale for HPLC detector, structure, use and evaluate information, see reference [10], [11] and [1] to [7] involved Detector content. This standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and Responsibility to develop appropriate safety and health practices.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. ASTME275 ultraviolet, visible and near infrared spectrophotometer performance characterization and test methods (Practicefordescribingand measuringperformanceofultraviolet, Visible, andnear-infraredspectrophotometers) ASTME682 term liquid chromatography (Practiceforliquidchromatographytermsandrelationships)

3 Terms and Definitions

ASTME682, and the following terms and definitions apply ASTME275 defined in this document. 3.1 Absorbance calibration absorbancecalibration Corrected absorbance within the range of ± 5% of the verification process. 3.2 Drift drift Measuring 1h, the average slope of the absorbance units per hour (AU/h) represents the noise envelope. 3.3 Dynamic dynamic At a flow rate of 1.0mL/min under the condition. 3.4 The linear range linearrange Variable wavelength photometric detector linear range of the mobile phase is to test the detector response versus concentration ratio constant in substance Concentration within the range of ± 5% corresponding to FIG. 1 and 7.2.2 have been described in detail. The linear range is the highest linear concentration and minimum detectable concentration Degrees or larger minimum linear concentration ratio.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32211-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32211-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32211-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32211-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information