US$1159.00 · In stock Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32204-2015: Industrial process calibrator Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 32204-2015 | English | 1159 |
Add to Cart
|
8 days [Need to translate]
|
Industrial process calibrator
| Valid |
GB/T 32204-2015
|
PDF similar to GB/T 32204-2015
Basic data | Standard ID | GB/T 32204-2015 (GB/T32204-2015) | | Description (Translated English) | Industrial process calibrator | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N21 | | Classification of International Standard | 25.040.40 | | Word Count Estimation | 55,589 | | Date of Issue | 2015-12-10 | | Date of Implementation | 2016-07-01 | | Quoted Standard | GB/T 2423.1-2008; GB/T 2423.2-2008; GB/T 2423.3-2006; GB/T 2423.5-1995; GB/T 2423.8-1995; GB/T 2423.10-2008; GB 4793.1-2007; GB/T 6113.101; GB/T 6113.102; GB/T 6113.103; GB/T 6113.104; GB/T 6113.201; GB/T 6113.202; GB/T 6113.203; GB/T 6113.204; GB/T 6113.402; GB/T 13384 | | Regulation (derived from) | National Standard Announcement 2015 No.38 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the terms and definitions, working conditions, classification, safety performance, general requirements, environmental tests, inspection regulations, inspection cycles, inspection methods and marking, packaging, transport and storage of industrial process calibrators. This standard applies to bench-top, hand-held calibrators. The scope of application includes all calibrators designed and manufactured in the People's Republic of China. This standard may also be applied to other similar instruments or equipment with partial output and measurement functions. |
GB/T 32204-2015: Industrial process calibrator---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Industrial process calibrator
ICS 25.040.40
N21
National Standards of People's Republic of China
Industrial Process Calibrator
Issued on. 2015-12-10
2016-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅴ
Introduction Ⅵ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 3 Operating Conditions
4.1 Normal working environment 3
4.2 Reference operating conditions 3
5 Category 3
5.1 According to the structure in the form of Class 3
5.2 Category 3 in accordance with power supply
6 Security features 4
6.1 Security 4
6.2 insulation 4
7 General requirements 4
7.1 Appearance 4
7.2 Function 4
7.3 Technical requirements 4
7.4 Electromagnetic compatibility 8
7.5 Power supply 9
9 8 Environmental Testing
8.1 high and low temperature test 9
8.2 Humidity Test 9
8.3 Vibration Test 9
8.4 drop test 9
9 8.5 Impact test
9 9 inspection rules
9.1 Test conditions 9
9.2 test category 9
9.3 factory inspection and determined that Rule 10
9.4 type of inspection, and failure classification results determined 10
9.5 Periodic Inspection 11
9.6 Test Item 11
9.7 testing equipment 12
10 Test Method 12
10.1 Security features 12
13 10.2 Appearance
10.3 Functional Check 13
10.4 Resolution 13
10.5 Indication Error 13
10.6 with a load capacity of 26
10.7 overload test 28
10.8 Input resistor 28
10.9 temperature on the amount of test 29
10.10 Effect of supply voltage variation amount 30
10.11 30 output stability test
Zero drift 30 10.12
10.13 31 series mode interference suppression
10.14 common-mode interference suppression 31
10.15 Electromagnetic Compatibility 32
10.16 Environmental Testing 33
11 signs, packaging, transportation and storage 33
11.1 mark 33
33 11.2 Packaging
11.3 Transportation and storage 33
Appendix A (informative) Uncertainty Evaluation Test Example 34
Annex B (informative) Periodic inspection records and test results 42
References 48
Figure 1 test DC voltage output wiring diagram 14
Figure 2 DC current output test wiring diagram 15
Figure 3 resistance test output wiring diagram 15
Figure 4 Frequency output wiring test Figure 16
5 thermocouple output wiring diagram (with a thermocouple reference junction temperature automatic compensation) 17
Figure 6 thermocouple output wiring diagram (thermocouple reference junction does not have automatic temperature compensation) 17
7 RTD analog output wiring diagram 18
8 DC voltage measurement test method standard source wiring diagram --- 19
9 DC voltage measurement test wiring diagram --- meter method 20
Figure 10 DC current measurement test method standard source wiring diagram --- 20
11 DC current measurement test wiring diagram --- meter method 21
12 resistance measurement test wiring diagram (DC resistance box) 22
13 resistance measurement test wiring diagram (using a multifunction calibrator) 22
14 Frequency Measurement test wiring diagram 23
15 thermocouple wiring diagram (with a thermocouple reference junction temperature automatic compensation) 24
16 thermocouple wiring diagram (thermocouple reference junction does not have automatic temperature compensation) 24
17 thermal resistance measurement test wire system wiring diagram --- 25
18 thermal resistance measurement test wiring diagram --- Three-wire 25
19 thermal resistance measurement test wiring diagram --- four-wire 25
20 with a load capacity test voltage wiring diagram 26
21 current load capacity test wiring diagram 27
Figure 22 Input resistance test wiring diagram 28
Test temperature on the amount of wiring diagram output 23/29 measurement functions
Figure 24 Output stability test wiring diagram 30
25 series mode rejection ratio test wiring diagram 31
26 common-mode rejection test wiring diagram 32
Table 1 Reference operating conditions Calibration 3
Table 2 calibrator output specifications 5
Table 3 Calibrator measures Technical indicators 6
Table 4 Calibrator failed inspection items and classification 10
Table 5 shows the error of the testing equipment 12
Table A.1 Standard uncertainty component summary (DC current output) 35
Table A.2 standard uncertainty component summary (thermocouple Analog Output) 37
Table A.3 Standard uncertainty component summary (DCV) 39
Table A.4 standard uncertainty component summary (RTD signal measurement) 41
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Machinery Industry Federation.
Control and automation Standardization Technical Committee (SAC/TC124) is under the jurisdiction of this standard is measured by the country's industrial processes.
This standard is drafted by. Shanghai Measurement and Testing Technology Research Institute, Yuyao Jin Instrument Factory, Ningbo Institute of Metrology, China
State ANCC, Beijing Const Instrument Technology Co., Ltd., China Institute of Metrology, YIMT test, Henan
Institute of Metrology Province, Fujian Shunchang Rainbow Run Precision Instrument Co., Ltd., Zhejiang Institute of Metrology, Quality and Technology Supervision Inspection Hangzhou
Measured hospital, Yunnan Electric Power Research Institute, Institute of Nuclear Physics and Chemistry Engineering Industry, Shanghai Guangdong International Trust and Friends of Industrial Company, Shanghai Electric Nuclear Power Equipment Co.
Division Shanghai New Oulong Industry Co., Ltd., Yokogawa Electric (China) Co., Ltd. Beijing R & D center in Shanghai line measurement and control technology
Main lab.
The main drafters of this standard. Yu Guorui, U Thant, Yuan Jing, Chen Xi, Zhang Jianfeng, Maoxiao Chen, He Xin, Sun Jian, Rao Jie, Chen Qingping, Yushi Fan,
Hang Fei Ni, Ding Ding, Yang Qing, Caokun Wu, Xie Hailin, Huang Li, Jiangyan Yun, Wu Zhengrong, Chen Zhiyang, Meng Pu.
Introduction
Industrial Process Calibrator is both output and measurement functions of the instrument can simultaneously measure the output or DC voltage, DC current,
Resistance, frequency, thermocouple, RTD and other industrial process signals, are widely used in industrial online calibration signal, fault diagnosis and research centers
Laboratories signal output and measurement. For the Unification of the industrial process calibrator manufacturing, product performance requirements and test specification Party
Law, it is necessary to standardize industrial process calibrator.
The standard calibration of industrial processes and product performance testing methods were provisions to regulate the production, use and inspection of industrial processes
Calibrator provides a reference and guidance.
Industrial Process Calibrator
1 Scope
This standard specifies the Industrial Process Calibrator (hereinafter referred to as the Calibrator) terms and definitions, working conditions, classification, security, performance, versatility to
Requirements, environmental testing, inspection rules, test period, test methods and marking, packaging, transport and storage.
This standard applies to desktop, handheld calibrator. Scope includes all the territory of People's Republic of China in the design and manufacture of school
Aligner.
This standard is also applicable to other similar instrument or device and having a portion of the output measurement.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test
GB/T 2423.5-1995 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock
GB/T 2423.8-1995 Environmental testing for electric and electronic products Part 2. Test methods Test Ed. Free fall
GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements
GB/T 6113 (all parts) radio disturbance and immunity measuring apparatus and methods -
GB/T 13384-2008 mechanical and electrical products packaging General technical conditions
GB/T 15479-1995 industrial automation instruments of insulation resistance, dielectric strength technical requirements and test methods
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test
GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test
GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity
test
GB/T 18271.3-2000 Process measurement and control devices - General methods and procedures for evaluating performance - Part 3. effects of influence quantities
Test
GB/T 25480-2010 instrumentation transportation, storage and basic environmental conditions and test methods
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Calibrator
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32204-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 32204-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 32204-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32204-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|