HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 32199-2015 English PDF

US$509.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 32199-2015: Standard practice for general techniques for obtaining infrared spectra for qualitative analysis
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 32199-2015English509 Add to Cart 5 days [Need to translate] Standard practice for general techniques for obtaining infrared spectra for qualitative analysis Valid GB/T 32199-2015

PDF similar to GB/T 32199-2015


Standard similar to GB/T 32199-2015

GB/T 40219   GB/T 25929   GB/T 25930   GB/T 32208   GB/T 32198   

Basic data

Standard ID GB/T 32199-2015 (GB/T32199-2015)
Description (Translated English) Standard practice for general techniques for obtaining infrared spectra for qualitative analysis
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N53
Classification of International Standard 71.040.10
Word Count Estimation 24,277
Date of Issue 2015-12-10
Date of Implementation 2016-07-01
Regulation (derived from) National Standard Announcement 2015 No.38
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 32199-2015: Standard practice for general techniques for obtaining infrared spectra for qualitative analysis


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard practice for general techniques for obtaining infrared spectra for qualitative analysis ICS 71.040.10 N53 National Standards of People's Republic of China Infrared spectroscopy qualitative analysis General Issued on. 2015-12-10 2016-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms, definitions and symbols 1 4 1 General Analysis of the liquid sample 4 5 Analysis of solid samples 6 7 Gas samples were analyzed 7 10 Analysis of the polymer 8 11 Other types of samples analyzed 9 15 10 special analysis 15 References 18

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard reference ASTME1252-2002 "Infrared spectroscopy qualitative analysis General." The standard proposed by China Machinery Industry Federation. Control and automation Standardization Technical Committee (SAC/TC124) is under the jurisdiction of this standard is measured by the country's industrial processes. This standard was drafted. China Instrument Industry Association, Peking University, Beijing Huayun Institute for the Analysis Instrument Co., Ltd., Beijing China Kechuang Instrument Technology Co., Ltd., Beijing Agricultural College, Beijing Analytical Instrument Institute. The main drafters of this standard. Maya Juan, Ong Fu, Tang Qingyun, elevation up, Zhang Xinmin, Louxing Jun. Infrared spectroscopy qualitative analysis General

1 Scope

1.1 standard spectral range covered is 4000cm-1 ~ 50cm-1, applies to the use of infrared spectroscopy for liquid, solid and gaseous Samples for qualitative analysis, qualitative analysis of the amount of the sample is not restricted. Wavenumber spectrum can also be used above the near-infrared region of 4000cm-1 Qualitative analysis. 1.2 This standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and We have the responsibility to develop appropriate safety and health practices. Specific preventive measures see 5.5.1.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. ASTME131 molecular spectroscopy related terms (TerminologyRelatingtoMolecularSpectroscopy) ASTME334 infrared microanalysis General Technology (PracticesforGeneralTechniquesofInfraredMicroanaly- sis) ASTME573 internal reflectance spectroscopy (PracticesforInternalReflectionSpectroscopy) ASTME1421 Fourier transform infrared (FT-IR) spectrometer characterization and measurement of. 0 and Level 1 is filled with zeros [Practice forDescribingandMeasuringPerformanceofFourierTransformInfrared (FT-IR) Spectrometers. LevelZeroandLevelOne] ASTME1642 Gas Chromatography - Infrared Spectroscopy (GC/IR) analysis of common technical [PracticeforGeneralTechniquesof GasChromatographyInfrared (GC/IR) Analysis] 3 Terms, definitions and symbols Terms, definitions and symbols ASTME131 defined in the application of this document.

4 General

4.1 Infrared (IR) is a qualitative analysis by identifying groups of [1] to [3], or compare the unknown sample with standard samples of known infrared absorption spectrum, Or a combination of both analysis methods. These spectra can be by means of infrared light transmission, reflection, and other technologies, such as photoacoustic spectroscopy (PAS) such as access to [4] to [8]. Spectra for comparison should be obtained under the same techniques and the same conditions. Users should note that not all public Open standard published spectra are entirely appropriate [9] - [16]. 4.1.1 IR instruments and accessories used in qualitative analysis can be obtained from commercial sources. User shall be provided in accordance with the manufacturer Manual operation, in order to ensure safe operation of equipment in the best condition. 4.2 will be a uniform thickness of the film sample is placed in the optical path of the infrared transmission spectra obtained vertical position (to eliminate interference generated sample film strip Grain method, see 8.5.1. Sample thickness should be appropriate, in the position of the absorption peak of the analyzed reaching the detector of infrared light energy to be reduced sufficiently low. The absorbance of the strongest absorption band is preferably between 1 and 2, the other band absorbance should be around 0.6. Since the polarity of the measured sample molecules exist Differences, there will be exceptions. For example, non-polar saturated hydrocarbons, CH2 asymmetric stretching vibration at 2920cm-1 has a strong absorption becomes

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32199-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32199-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32199-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32199-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information