| US$469.00 · In stockDelivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
 GB/T 31462-2015: Main body technical specification for 500 kV and 750 kV multistage controlled shunt reactors
 Status: Valid
 
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| GB/T 31462-2015 | English | 469 | Add to Cart | 4 days [Need to translate] | Main body technical specification for 500 kV and 750 kV multistage controlled shunt reactors | Valid | GB/T 31462-2015 |  
	 
       PDF similar to GB/T 31462-2015 
 Basic data             | Standard ID | GB/T 31462-2015 (GB/T31462-2015) |           | Description (Translated English) | Main body technical specification for 500 kV and 750 kV multistage controlled shunt reactors |           | Sector / Industry | National Standard (Recommended) |           | Classification of Chinese Standard | K41 |           | Classification of International Standard | 29.180 |           | Word Count Estimation | 22,263 |           | Date of Issue | 2015-05-15 |           | Date of Implementation | 2015-12-01 |           | Quoted Standard | GB 1094.1; GB 1094.2; GB 1094.3; GB/T 1094.4; GB/T 1094.6; GB/T 1094.10; GB 2536; GB/T 2900.15; GB/T 2900.17; GB/T 2900.49; GB/T 4109; GB/T 7252; GB/T 11604; GB 20840.2; DL/T 911; JB/T 3837 |           | Regulation (derived from) | National Standard Announcement 2015 No. 15 |           | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |           | Summary | This Standard specifies the classification controllable shunt reactor body of terms and definitions, product type, conditions of use, nameplates, performance parameters, technical requirements, testing, marking, packaging, transportation and storage requirements, and are given in Appendix A neutral point reactor basic parameters. This Standard applies to 500 kV and 750 kV voltage power systems using single-phase rating controllable shunt reactor body, other voltage levels and three-phase rating controllable shunt reactor body may use of the reference standard. | GB/T 31462-2015: Main body technical specification for 500 kV and 750 kV multistage controlled shunt reactors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 Main body technical specification for 500 kV and 750 kV multistage controlled shunt reactors
ICS 29.180
K41
National Standards of People's Republic of China
500kV and 750kV level grade controllable parallel
Reactor body Technical Specifications
Issued on. 2015-05-15
2015-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
 Table of ContentsPreface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Model 2
Conditions 5 2
6 Nameplate 3
Performance parameters 4 7
8 6 Technical Requirements
9 Test 7
10 signs, packaging, transportation and storage 13
Appendix A (informative) neutral point reactor 15 basic parameters
Annex B (informative) Classification controllable shunt reactor works 17
Figure B.1 rating controllable shunt reactor schematics 17
Table 1 rating controllable shunt reactor body temperature rise limit of 5
Table 2 Classification controllable shunt reactor body over-excitation capability 6
Table 3 Routine test item 8
Table 4 Type test item 8
Table 5 special pilot projects 9
Table A.1 insulation level neutral point reactor 16
Table B.1 rating controllable shunt reactor capacity switching control table 18ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee transformers (SAC/TC44) centralized.
This standard was drafted. State Grid Smart Grid Research Institute, Shenyang Transformer Research Institute Co., Ltd., State Grid Power Supply Company in Yulin, China
Power Engineering Northwest Electric Power Design Institute, State Grid Electric Power Research Institute Consulting Group, Gansu Electric Power Company of science, State Grid Qinghai Electric Power Company, South
Power Research Institute, Xi'an Electric Transformer Co., Ltd., TBEA Shenyang Transformer Group Co., Ltd., State Nuclear Electric Power Planning and Design
Total Research Institute, China Power Engineering Consulting Group Northeast Electric Power Design Institute, China Power Engineering Consulting Group in North China Power Engineering Co.
Division, the China Power Engineering Consulting Group Southwest Electric Power Design Institute, Baoding Tianwei Electric Co., Ltd., State Grid Power Company in Gansu Province, Country
Home Transformer Quality Supervision and Inspection Center.
The main drafters of this standard. Lei Xi, Liu Jie, Sun Qiang, Wang Liyan, Wu Shou far, Wang Weizhou, Tiansheng Xiang, Cai Hansheng, Chen, Zhang Hai Ting, Zhang Zhong country,
Mazhong Kun, Cai Jinbo, European army, and Lee was, Lihong Xiu, Liu Yang, Han Xu Shan, Li Wenhai, Wan Feng Tao, a new paragraph, Liang Bo, Ma Yunfei, Li Zhi, Zhou Xi Chao,
Mengqing Min, Su Guang, Jiang Dapeng, Liuxi Zhong, Li Yunlong, Triton.
500kV and 750kV level grade controllable parallel
Reactor body Technical Specifications1 ScopeThis standard specifies the classification controllable shunt reactor body of terms and definitions, product type, conditions of use, nameplate, performance parameters, technical
Operation requirements, testing, marking, packaging, transportation and storage requirements, and gives a neutral point reactor basic parameters in Appendix A.
This standard applies to 500kV and 750kV voltage power system for use in single-phase rating controllable shunt reactor body, which
He and three-phase voltage rating controllable shunt reactor body may refer to this standard.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 1094.1 Power transformers - Part 1. General
Temperature liquid-immersed transformers. GB 1094.2 Power transformers - Part 2
GB 1094.3 Power transformers Part 3. Insulation levels, dielectric tests and external insulation air gap
GB/T 1094.4 Power transformers - Part 4. Power transformers and reactors lightning impulse and switching impulse testing guidelines
GB/T 1094.6 Power transformers - Part 6. Reactors
Part of GB/T 1094.10 Power Transformer 10. Determination of sound levels
GB 2536 Electrical transformers and switching fluid unused mineral insulating oils
GB/T 2900.15 Electrotechnical terminology transformers, transformers, regulators and reactors
GB/T 2900.17 Electrotechnical terminology measuring relays
GB/T 2900.49 Electrotechnical terminology - Power System Protection
GB/T 4109 is higher than 1000V AC voltage bushings
GB/T 7252 transformer oil dissolved gas analysis and judgment Guide
GB/T 11604 high-voltage electrical equipment radio interference test method
Additional technical requirements for current transformers. GB 20840.2 transformers - Part 2
DL/T 911 power transformer winding deformation frequency response analysis
JB/T 3837 Transformer Model methodology3 Terms and DefinitionsGB/T 2900.15, GB/T 2900.17, GB/T 2900.49 and GB/T 1094.6 and define the following terms and definitions apply
This document.
3.1
Controllable Shunt Reactor controledshuntreactor; CSR
In parallel with the power system reactance values \u200b\u200bcan be adjusted online reactor.
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31462-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 31462-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 31462-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31462-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.    |